DOWNLOAD Sharp 66ES-D7H (serv.man34) Service Manual ↓ Size: 584.92 KB | Pages: 10 in PDF or view online for FREE

Model
66ES-D7H (serv.man34)
Pages
10
Size
584.92 KB
Type
PDF
Document
Service Manual / Technical Bulletin
Brand
Device
TV / CTR / NVM replacement procedure, resetting and faults experienced on the DA100(50Hz) chassis
File
66es-d7h-sm34.pdf
Date

Sharp 66ES-D7H (serv.man34) Service Manual / Technical Bulletin ▷ View online

CTV2001 03 02
Month of Issue:  
July 2001
        
Classification: 
Yellow
TELEVISION TECHNICAL BULLETIN
Page 5 of 10
Sharp Electronics (UK) Limited
Revision  4
White – Carry out as required
Yellow – Carry out as required and whenever the unit comes in for service
 Red – Carry out on all units
Service Tool - Reprogramming the NVM
REASON
A service tool has been introduced to assist in reprogramming the NVM.  This tool will
enable the engineer to reprogram the NVM, even if the set does not turn on (provided
that there is a 5V supply to the microprocessor, NVM and OTP).
Typical fault symptoms if the NVM is damaged include problems with the picture,
teletext or sound.
ACTION
To reprogram the NVM, proceed as follows:
1.  Replace IC1002 (OTP) with the service jig.
2.  Turn on the television.  Note that the set will appear to be dead with both LED's
illuminated.
3.  Wait until the blanking process is complete.  During the blanking process, the
NICAM will flash ten times, stop, then flash ten times again.  This process will
continue indefinitely.  The NVM will be blanked when the LED stops flashing for the
first time (this may take up to 50 seconds after turning the set on).
4.  Switch off the set at the mains.
5.  Refit the original OTP.  It is important to ensure that the OTP contains the latest
version of software for the combination of model, CRT and Megatext IC (see
technical bulletin CTV2001 05 04).
6.  Switch on, the set will appear to be dead with both LED on for about the first 30 to
60 seconds while the NVM is being programmed.  If the set is turned off during this
period, it will be necessary to repeat this procedure from step 1.  Once the NVM
programming is complete the set will start up automatically.
7.  Adjust the tuning, grey scale, AGC, AFT and picture geometry a necessary.
REF NO
DESCRIPTION
PART NUMBER
PRICE CODE
Service Jig
FW-SERV-JIG01
AZ
Back to top of file
CTV2001 03 02
Month of Issue:  
July 2001
        
Classification: 
Yellow
TELEVISION TECHNICAL BULLETIN
Page 6 of 10
Sharp Electronics (UK) Limited
Revision  4
White – Carry out as required
Yellow – Carry out as required and whenever the unit comes in for service
 Red – Carry out on all units
SYMPTOM In some instances, when a RGB signal is applied to the EURO-SCART socket, the
brightness varies with picture content.
CAUSE
Incorrect black level clamping.
ACTION
Adjust NVM data on page 0D, position 0C from 73 to 57.
SYMPTOM Set fails to start, green LED stays on permanently.  Only one burst of activity on the
NVM I
2
C bus.
CAUSE
Serial data problem.
ACTION
Remove the NVM (IC1003) and turn the set on.
If the LED gives two flashes, this means that there is no NVM data and that the
processor and OTP are working correctly.  This probably means that the NVM is
faulty.
REF NO
DESCRIPTION
PART NUMBER
PRICE CODE
IC1003
IC, NVM
RH-IX1603BMZZ
AV
SYMPTOM Low contrast, but when the test mode is entered, it returns to normal.
CAUSE
NVM corrupted.
ACTION
Adjust G2 as described on Technical Bulletin CTV2000 01 04.
NB. If the fault does not clear, replace the NVM.
REF NO
DESCRIPTION
PART NUMBER
PRICE CODE
IC1003
NVM
RH-IX1603BMZZ
AV
Back to top of file
Back to top of file
Back to top of file
CTV2001 03 02
Month of Issue:  
July 2001
        
Classification: 
Yellow
TELEVISION TECHNICAL BULLETIN
Page 7 of 10
Sharp Electronics (UK) Limited
Revision  4
White – Carry out as required
Yellow – Carry out as required and whenever the unit comes in for service
 Red – Carry out on all units
SYMPTOM After changing the NVM (or possibly due to data corruption), the half page text
appears in the wrong part of the screen - too far left or right.
CAUSE
Corruption of NVM memory.
ACTION
Enter the service mode and change the following NVM position to the value shown.
Page:
00
Position:
68
Value:
36
Note: To enter the service mode, take the following steps.
1.  Turn the set on and ensure that a picture is being displayed.
2.  Turn the set off using the mains switch.
3.  Press the volume down and channel up buttons on the front of the set.
4.  Keeping the buttons pressed, turn the set on using the mains switch.
5.  Release the buttons when the service mode is displayed.
Use the channel buttons to move between functions, the volume buttons to change
values and the standby button to store.
Back to top of file
CTV2001 03 02
Month of Issue:  
July 2001
        
Classification: 
Yellow
TELEVISION TECHNICAL BULLETIN
Page 8 of 10
Sharp Electronics (UK) Limited
Revision  4
White – Carry out as required
Yellow – Carry out as required and whenever the unit comes in for service
 Red – Carry out on all units
SYMPTOM NVM corruption.
CAUSE
Arcing can occur on the CRT base panel (PWB-B) caused by CRT discharges.
ACTION
Add capacitors C1826 and C1827 as shown in the picture below.
Models produced after the following serial numbers already have the capacitors fitted:
66FW53H
726200
66FW54H
714595
76FW53H
713664
76FW54H
714633
REF NO
DESCRIPTION
PART NUMBER
PRICE CODE
C1826
Ceramic capacitor 4.7nf 10% 500V
VCKYPA2HB472K
AB
C1827
Ceramic capacitor 10nf  20% 250V
RC-KZ0029CEZZ
AC
Back to top of file
Page of 10
Display

Click on the first or last page to see other 66ES-D7H (serv.man34) service manuals if exist.