DOWNLOAD Sharp XG-P20XE Service Manual ↓ Size: 1.14 MB | Pages: 56 in PDF or view online for FREE

Model
XG-P20XE
Pages
56
Size
1.14 MB
Type
PDF
Document
Handy Guide
Brand
Device
Projector / Version 1.4
File
xg-p20xe.pdf
Date

Sharp XG-P20XE Handy Guide ▷ View online

Electrical Adjustments
Version 1.4
Issue 04/2006
41
SHARP ELECTRONICS (UK) LTD
PROJECTOR TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
ELECTRICAL ADJUSTMENT
No.
Adjustment Items
Adjustment Conditions
Adjustment Procedures
1
Initialization of
EEPROM
1. Turn on the power (the lamp lights
up) and warm up the system for 15
minutes.
Make the following settings:
Press S2601 to call up the process mode
and execute S2 and S4 in the SSS menu.
Now the system, with the PC board not
included, is initialized.
Do not execute S1 because otherwise the
PC board will be initialized.
To adjust the PC board, follow the
Instruction in "Adjusting the PC Interface".
2
R drive
1. Make the following choice.
Group : A/D
2. Feed the 100% red-only signal.
Make the following choice.
Group : A/D
Subject : R-D
Using the control switches or the remote
controller buttons, adjust the data so that the
signal becomes bit-less (noise).
3
B drive
1. Feed the 100% blue-only signal.
Make the following choice.
Group : A/D
Subject : B-D
Using the control switches or the remote
controller buttons, adjust the data so that the
signal becomes bit-less (noise).
4
G drive
1. Feed the 100% green-only signal.
Make the following choice.
Group : A/D
Subject : G-D
Using the control switches or the remote
controller buttons, adjust the data so that the
signal becomes bit-less (noise).
5
RGB 1 system black level
signal amplitude (odd-
numbered)
1. Make the following choice:
Group : OUTPUT 1
Subject : G1-BLK
G1-GAIN
For green, choose the subjects R1-
BLK and R1- GAIN.
For blue, choose the subjects B1-BLK
and B1-GAIN.
2. Connect the oscilloscope to
TP1101 for red.
TP1201 for green
TP1301 for blue
• 
Choose the subject G1-GAIN and
adjust the signal amplitude to 3.9 ±0.05
Vp-p using the control switches or the
remote controller buttons.
• 
Next, choose the subject G-BLK and
adjust the white peak level to 2.0Vp-p
±0.1V.
• 
Make the same adjustments for green
and blue.
6
P SIGNAL
1. Connect the oscilloscope to
TP1102 for red.
2. Make the following choice:
Group : OUTPUT 2
Subject : PSIG-H
: PSIG-L
• 
Adjust the PSIG waveform to the one
shown below.
• 
For the green and blue colours, make
sure their waveforms are similar to that
of the red colour.
Electrical Adjustments
Version 1.4
Issue 04/2006
42
SHARP ELECTRONICS (UK) LTD
PROJECTOR TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
No.
Adjustment Items
Adjustment Conditions
Adjustment Procedures
7
Sample-and-hold pulse
phase
RCK-PHASE
GCK-PHASE
BCK-PHASE
1. Feed the XGA mode 75-Hz black
signal.
2. Make the following choice:
Group : OUTPUT 3
Subject : SH-PHASE
(Have the standard level at 8.)
Fix the GCK-PHASE settings all to 8.
Using the control switches or the remote
controller buttons, make sure that the
“OUTPUT 3” characters are not blurry and
there is no ghost image. If such blur or ghost
occurs, finely adjust the setting in the range
of 7~9.
8
RGB countervoltage
adjustment
1. Feed the black-and-red (25%)
stripe signal (XGA).
2. Make the following choice:
Group : OUTPUT 3
Subject : RC (R)
: BC (B)
: GC (G)
• 
Using the control switches or the
remote controller buttons, adjust the
data in order to minimise the flicker.
• 
Make the same adjustment for BC (B)
and GC (G).
• 
See if the image is equally adjusted at
the centre and both sides of the screen.
If not, readjust the setting to have the
image equal at right and left.
9
RGB gradation
regeneration
adjustment
1. Feed the INFO COM. Grey scale
and colour bar pattern.
2. Make the following choice:
Group : OUTPUT 1
Subject : G1-BLK
• 
Make sure that scale (white side) to
No.251 and scale (black side) to No.8
can be seen.
• 
If white scale can't be seen properly,
readjust with G1-BLK.
10
RGB white
balance
1. Feed the 32-step grey scale signal
(XGA 60Hz).
Group : OUTPUT 1
Subject : R1-BLK (R)
R1-GAIN(R)
B1-BLK (B)
B1-GAIN(B)
Adjust the R1-BLK and B1-BLK data for the
black balance on the gray scale. Then adjust
the R1-GAIN and B1-GAIN data for the
centre-to-white balance on the grey scale.
(Adjust to the best point.)
11
Horizontal centre
1. Feed the NTSC monoscope pattern
signal.
2. Group : VIDEO 1
Subject : NTSC-H
Using the control switches or the remote
controller buttons, adjust the data to have
the same overscan.
12
Video brightness
adjustment
1. Feed the baseband (0 step grey
scale :0% Black to 100% White)
signal.
Group : VIDEO 1
Subject : BRIGHT
2. Press the control switch or the
remote control’s mute button (to set
the gamma correction to the process
setting).
Using the control switches or the remote
controller buttons, adjust the setting until the
black signal (0%) becomes bit-less.
13
Video picture
adjustment
1. Feed the split colour bar signal.
Group : VIDEO 1
Subject : PICTURE
2. Connect the oscilloscope between
pin TP1201and GND.
Using the control switches or the remote
controller buttons, adjust the white to white
(100%) level difference to 2.2 ± 0.05 Vp-p.
Electrical Adjustments
Version 1.4
Issue 04/2006
43
SHARP ELECTRONICS (UK) LTD
PROJECTOR TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
No.
Adjustment Items
Adjustment Conditions
Adjustment Procedures
14
Tint
1. Feed the split colour bar signal.
Group : VIDEO 1
Subject : TINT
2. Connect the oscilloscope to
TP1301.
Using the control switches or the remote
controller buttons. Adjust the setting so that
the points indicated in the waveform figure
are at the same level.
15
NTSC colour saturation
level
1. Feed the split colour bar signal.
Group : VIDEO 1
Subject : N-COLOR
2. Connect the oscilloscope to
TP1101.
Using the control switches or the remote
controller buttons, adjust the difference
between the 100% white portion and the red
portion to 0.25 ±0.02 Vp-p. (same as 100%
white)
16
PAL colour saturation level
1. Feed the PAL colour bar signal.
Group : VIDEO 1
Subject : P-COLOR
2. Connect the oscilloscope to
TP1101.
Using the control switches or the remote
controller buttons, adjust the difference
between the 100% white portion and the red
portion to 0.3 ±0.02 Vp-p.
17
SECAM colour saturation
level
1. Feed the SECAM colour bar signal.
Group : VIDEO 1
Subject : S-COLOR
2. Connect the oscilloscope to
TP1101.
Using the control switches or the remote
controller buttons, adjust the data to have a
level difference of 0.3 ±0.02 Vp-p between
the 100% white portion and the red portion.
18
Video white
balance
1. Feed the NTSC monoscope pattern
signal
Group : VIDEO 2
Subject : R1-BLK
B1-BLK
Using the control switches or the remote
controller buttons, adjust so that the entire
screen looks evenly colourless.
Electrical Adjustments
Version 1.4
Issue 04/2006
44
SHARP ELECTRONICS (UK) LTD
PROJECTOR TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
No.
Adjustment Items
Adjustment Conditions
Adjustment Procedures
19
DVD Contrast
1. Feed the colour bar signal of the
480I component signal to the BNC
G(Y) input terminal.
2. Select the following subject.
Group : DVD
Subject : CONTRAST
Using the control switches or the remote
controller buttons, adjust the white to white
(100%) level difference to 2.2 ± 0.05v p-p.
20
DVD Brightness
1. Feed the colour bar signal of the
480I component signal to the BNC
G(Y) input terminal.
2. Select the following subject.
Group : DVD
Subject : CONTRAST
Using the control switches or the remote
controller buttons, adjust the setting until the
black signal (0%) becomes bit-less.
21
DVD Tint
1. Feed the colour bar signal of the
480I component signal to the BNC Y,
Pb and Pr input terminals. Feed the
sync signal only for the Y signal.
2. Select the following subject.
Group : DVD
Subject : TINT
3. Connect the oscilloscope to
TP1301.
Using the control switches or the remote
controller buttons. Adjust the setting so that
the points indicated in the waveform figure
are at the same level.
22
DVD Colour
1. Feed the colour bar signal of the
480I component signal to the BNC G
(Y) input terminal.
2. Select the following subject.
Group : DVD
Subject : COLOR
3. Connect the oscilloscope to
TP1101.
Adjust the level difference between the
100% white and red portions to 0.3 ±0.02
Vp-p.
23
DVD White balance
adjustment
1. Feed the NTSC monoscope signal
to G(Y) input terminal of the BNC
terminal.
2. Select the following subject.
Group : DVD
Subject : R1-BLK
B1-BLK
Adjust so that a white balance may become
the best condition by using the control switch
or buttons of the R/C.
24
Checking and readjustment
of white balance
1.The adjustment condition of each
item is as mentioned in the following.
RGB input:Refer to No.11
VIDEO input:Refer to No.19
DVD input:Refer to No.23
Make sure that a white balance is the best
condition.
25
Colour system performance
check
1. Receive the colour bar signal.
In the process mode and select L1. Check
the colour and tint.
26
Video system performance
check
1. Receive the monoscope pattern
signal.
In the process mode and select L2. Check
the picture, brightness and sharpness.
27
Audio system performance
check
In the process mode nad select L3. Check
the bass, treble and balance.
Page of 56
Display