9
XG-NV7XE
XG-NV7XM
2
Be sure the supplied remote mouse receiver is connected to your computer.
Slide the MOUSE/ADJUSTMENT switch to MOUSE.
Effective buttons in MOUSE mode
Use as a Wireless Mouse
1
MOUSE
ADJ.
Use as a Laser pointer
Slide the MOUSE/ADJUSTMENT switch to MOUSE.
Press LASER POINTER (
) to activate the laser pointer.
When the button is released, the light automatically goes off.
• For safety, the laser pointer automatically goes off after 1 minute of continuous use. To turn it on,
release LASER POINTER (
) and press again.
MOUSE
ADJ.
1
• The wireless mouse may not operate correctly if your computer serial port is not correctly set up. Refer
to the computer’s operation manual for details of setting up/installing the mouse driver.
• For one-button mouse systems, use either the  LEFT-CLICK or RIGHT-CLICK button.
Using the remote control in a dark room
Press BACKLIGHT, and the buttons will light up. Green lights refer to mouse operations, and red
lights to projector adjustments.
Position of MOUSE/ADJUSTMENT switch
ON (RED)
MOUSE 
LASER POINTER (GREEN)
BLACK SCREEN (GREEN)
RIGHT-CLICK (GREEN)
MOUSE (NOT LIT)
LEFT-CLICK (NOT LIT)
ADJ. 
MENU (RED)
KEYSTONE (RED)
ENTER (RED)
ADJUSTMENT (NOT LIT)
UNDO (NOT LIT)
Button name
LASER POINTER/MENU
BLACK SCREEN/KEYSTONE
RIGHT-CLICK/ENTER
MOUSE/ADJUSTMENT
LEFT-CLICK/UNDO
POWER ON/OFF
VOLUME 
+
/
MUTE
Position of MOUSE/ADJUSTMENT switch
ON (RED)
MOUSE 
ADJ. 
Button name
INPUT
IrCOM
FREEZE
AUTO SYNC
ENLARGE
RESIZE
TOOLS
GAMMA
LEFT-CLICK
RIGHT-CLICK
MOUSE
BLACK SCREEN
LASER
POINTER
10
XG-NV7XE
XG-NV7XM
Connection Pin Assignments
Analog Computer 1 Signal Input Port: 15-pin mini D-sub female connector
Computer Input
Analog
1. Video input (red)
2. Video input
(green/sync on green)
3. Video input (blue)
4. Reserve input 1
5. Composite sync
6. Earth (red)
7. Earth (green/sync on green)
8. Earth (blue)
9. Not connected
10. GND
11. GND
12. Bi-directional data
13. Horizontal sync signal
14. Vertical sync signal
15. Data clock
1
15
5
6
11
10
Pin No.
Signal
Name
I/O
Reference
1
CD
Not connected
2
RD
Receive Data
Input
Connected to internal circuit
3
SD
Send Data
Output
Connected to internal circuit
4
ER
Not connected
5
SG
Signal Ground
Connected to internal circuit
6
DR
Data Set Ready
Output
Not connected
7
RS
Request to Send
Output
Connected to internal circuit
8
CS
Clear to Send
 Input
Connected to internal circuit
9
CI
Not connected
Pin No.
Signal
Name
I/O
Reference
1
VCC
+
3.3V (Reserved)
Output
Not connected
2
RD
Receive Data
Input
Connected to internal circuit
3
SD
Send Data
Output
Connected to internal circuit
4
EXIR
Detector of Option Unit
Input
Not connected
(Reserved)
5
SG
Signal Ground
Connected to internal circuit
6
ERX
IR Receive Signal from
Input
Not connected
IR Amplifire (Reserved)
7
RS
Request to Send
Output
Connected to internal circuit
8
CS
Clear to Send
Input
Connected to internal circuit
9
ETX
IR Transmit Signal
Output
Not connected
(Reserved)
RS-232C Terminal:  9-pin mini DIN connector
6
8
4
9
7
3
5
2
1
RS-232C Port: 9-pin D-sub male connector of the DIN-D-sub RS-232C cable
1
5
6
9
Pin No.
Signal
Name
Reference
1
RX0
Blue Input (
)
Connected to internal circuit
2
RX0
+
Blue Input (
+
)
Connected to internal circuit
3
RX0 SHIELD
Panel Link Shield
Connected to internal circuit
4
RX2 SHIELD
Panel Link Shield
Connected to internal circuit
5
RX2
Red Input (
)
Connected to internal circuit
6
RX2
+
Red Input (
+
)
Connected to internal circuit
7
DDC/SCL
SCL
Connected to internal circuit
8
DDC/SDA
SDA
Connected to internal circuit
9
NC
N.C.
Not connected
10
NC
N.C.
Not connected
11
RXC
Clock Input (
)
Connected to internal circuit
12
RXC
+
Clock Input (
+
)
Connected to internal circuit
13
RXC SHIELD
Panel Link Shield
Connected to internal circuit
14
RX1 SHIELD
Panel Link Shield
Connected to internal circuit
15
RX1
Green Input (
)
Connected to internal circuit
16
RX1
+
Green Input (
+
)
Connected to internal circuit
17
NC
N.C.
Not connected
18
SENS
SENS
Connected to internal circuit
19
DDC 
+
5V DC
+
5V
Connected to internal circuit
20
DDC GND
GND
Connected to internal circuit
PanelLink™ Port: MDR-type 20-pin connector
10
20
11
1
11
XG-NV7XE
XG-NV7XM
Dimensions
Units: mm
Rear View
219
37.5
82
312.5
8.1
1.2
71.5 
58
235
212
Front View
Top View
Side View
Bottom View
12
XG-NV7XE
XG-NV7XM
REMOVING OF MAJOR PARTS
1. Removing the Lamp Unit
1-1. Remove the screw from the lamp cover and detach the lamp cover.
1-2. Remove the three screws from the lamp unit and take out the lamp unit.
1-2
1-1
Lamp Unit
Lamp Cover
Page of 43
Display

Click on the first or last page to see other XG-NV7XE (serv.man3) service manuals if exist.