DOWNLOAD Sharp XG-NV4SE (serv.man4) Service Manual ↓ Size: 2.62 MB | Pages: 28 in PDF or view online for FREE

Model
XG-NV4SE (serv.man4)
Pages
28
Size
2.62 MB
Type
PDF
Document
Service Manual
Brand
Device
Projector / Section 1 - Text - page 1-28
File
xg-nv4se-sm4.pdf
Date

Sharp XG-NV4SE (serv.man4) Service Manual ▷ View online

21
XG-NV4SE/SM
XG-NV40SA
Replacing the LCD panels
Detach the top panel and the optical mechanism unit in advance.
(1) Remove the four prism holder lock screws. Detach the prism holder from the optical mechanism unit.
(2) Remove the LCD panel lock screws (three each for the R-, G- and B-LCD panels). Detach the LCD panels from the
prism holder.
(3) Mount a new LCD panel in the reverse order of the above steps (1) and (2).
~
Readjust the convergence and focus. Note that the G-LCD panel needs no convergence adjustment and has
a small adjustment range in the Z direction.
1
G-LCD
SIDE VIEW
G-LCD panel 
mounting screws
Lock screw "d"
Lock screw "d"
R·B·LCD panel 
mounting screws
R·B-LCD
SIDE VIEW (from inside)
Prism holder
Optical Mechanism Unit
2
2
22
XG-NV4SE/SM
XG-NV40SA
Adjusting the optical axis of the mirrors (M1, M5 and M4/M6)
The optical axis must be readjusted if an eclipse happens with the R. G or B mirrors. Generally speaking,
this adjustment is needed when any of the internal optical components has been replaced.
Adjustment procedure required when any of the panels has been replaced or the convergence has been
adjusted
(1) Disconnect the flat cables of all the LCD panels.
(2) Let the lamp light up.
(3) To adjust the G mirror, shield the R and B mirrors with shielding plates (You can use a business card or the like to
block the light).
(4) Loosen the lock screw of the M1 adjust lever.
(5) Looking at the G image on the screen, turn or slide the M1 adjust lever until the eclipse on the screen disappears.
Tighten up the screw.
(6) To adjust the R mirror, shield the G and B mirrors and adjust the M5 adjust lever. For the B mirror, shield the R and
G mirrors and adjust the M6 adjust lever.
(Take the same steps 4 and 5 above.)
(7) Remove all the shielding plates to have a white image.
Make sure there is no eclipse.
FRONT
M5
 adjust lever
Lock screws
Lock screws
M4/M6
 adjust lever
Lock screws
M1
 adjust lever
Shielding plate G
slide
turn
turn
slide
turn
slide
Shielding plate R
Shielding plate B
23
XG-NV4SE/SM
XG-NV40SA
ELECTRICAL ADJUSTMENT
Hook up a signal generator, or a DOSV or Mac personal computer to the projector in order to feed the
signals specified in the Adjusting conditions.
No.
Adjusting point
Adjusting conditions
Adjusting procedure
1
EEPROM
initialization
1. Turn on the power (make
sure the lamp lights up) and
warm up the unit for 15 min-
utes.
»
Make the following settings:
Press S5001 to call up the process mode and
execute S2 in the SSS menu. Now the system, with
the PC board not included, is initialized. Do not
execute S1 because otherwise the PC board will be
initialized.
To adjust the PC board, follow the instruction in
"Adjusting the PC board". (See page 28)
2
R drive
1. Make the following choice.
Group : A/D
Subject : GAIN
Make sure the GAIN value
is 163.
2. Make the following choice:
Group : OUTPUT 2
Subject : BRIGHT
Reduce the brightness level
by 4 points.
3. Feed the 100% red-only sig-
nal. Make the following
choice.
Group : A/D
Subject : R-D
»
Using the control switches or the remote controller
buttons, adjust the data so that the signal becomes
bit-less (noise).
3
B drive
1. Feed the 100% blue-only
signal. Make the following
choice.
Group : A/D
Subject : B-D
»
Using the control switches or the remote controller
buttons, adjust the data so that the signal becomes
bit-less (noise).
4
G drive
1. Feed the 100% green-only
signal. Make the following
choice.
Group : A/D
Subject : G-D
»
Using the control switches or the remote controller
buttons, adjust the data so that the signal becomes
bit-less (noise).
24
XG-NV4SE/SM
XG-NV40SA
No.
Adjusting point
Adjusting conditions
Adjusting procedure
5
RGB 1 system
black level
signal amplitude
(odd-numbered)
»
 Choose the subject R1-GAIN and adjust the signal
amplitude to 3.6 ±0.1 Vp-p using the control switches
or the remote controller buttons.
»
Next,choose the subject R1-BLK and adjust the black
peak level to 2.4 ±0.1V DC.
1. Make the following choice:
Group : OUTPUT 1
Subject : R1-BLK
R1-GAIN
For green, choose the sub-
    jects G1-BLK and G1-
GAIN.
For blue, choose the sub-
jects B1-BLK and B1-GAIN.
2. Connect the oscilloscope to
TP1101  for red.
    TP1201  for green
    TP1301  for blue
6
P SIGNAL
1. Connect the oscilloscope to
TP1102 for red.
    TP1202 for green
    TP1302 for blue.
2. Make the following choice:
Group : OUTPUT 2
Subject : R2-GAIN
 
»
Using the control switches or the remote controller
buttons, adjust the waveform become as follows.
 
»
 Make sure the waveform of the green and blue are
same as red.
7
Sample-and-
hold pulse
phase
RCK-PHASE
GCK-PHASE
BCK-PHASE
1. Feed the XGA mode 75-Hz
black signal.
2. Make the following choice:
Group : OUTPUT 3
Subject : SH-PHASE
(Have the standard level at
8.)
Fix the R-, G- and B-
PHASE settings all to 8.
»
Using the control switches or the remote controller
buttons, make sure that the “OUTPUT 3” characters
are not blurry and there is no ghost image. If such
blur or ghost occurs, finely adjust the setting in the
range of 7~9.
7V DC
2.5V DC
GND
»
Adjust the signal's amplitude and maximum black
level to 3.3 ± 0.1Vp-p and 2.6 ± 0.1V DC, respec-
tively, for green and blue.
»
Make sure the BLK DATA is more than 100.
3.6Vp-p
2.4V DC 
  (Adjust to 2.6V DC for green and blue.)
(Adjust to 3.3Vp-p
 for green and blue.)
Page of 28