51
Appendix
Removing and Installing
the Lamp Unit
• Do not touch the glass surface of the lamp
unit or the inside of the projector.
• To avoid injury to yourself and damage to the
lamp, make sure you carefully follow the steps
below.
• Do not loosen other screws except for the
lamp unit cover and lamp unit.
Press STANDBY/ON on the projec-
tor or STANDBY  on the remote
control to put the projector into
standby mode.
• Wait until the cooling fan stops.
 Warning!
• Do not remove the lamp unit from the projec-
tor right after use. The lamp and parts around
the lamp will be very hot and may cause burns
or injury.
Disconnect the power cord.
• Unplug the power cord from the AC
socket.
• Leave the lamp until it has fully cooled
down (about 1 hour).
Remove the lamp unit cover.
• Turn the projector over. Loosen the user
service screw (1) that secures the lamp
unit cover. Remove the lamp unit cover
(2).
Lamp unit
AN-XR30LP
Info
Optional
accessory
AC socket
User service screw
(for lamp unit cover)
1
2
3
STANDBY/ON button
1
2
PGF150X_E_P47_62.p65
07.5.31, 6:30 PM
51
52
Regarding the Lamp (Continued)
Remove the lamp unit.
• Loosen the securing screws from the
lamp unit. Hold the lamp unit and pull it
in the direction of the arrow. At this time,
keep the lamp unit horizontal and do not
tilt it.
Resetting the Lamp Timer
Reset the lamp timer after replacing the lamp.
Insert the new lamp unit.
• Press the lamp unit firmly into the lamp
unit compartment. Fasten the securing
screws.
Replace the lamp unit cover.
• Align the tab on the lamp unit cover
(1) and place it while pressing the tab
(2) to close it. Then tighten the user ser-
vice screw (3) to secure the lamp unit
cover.
4
5
6
Connect the power cord.
• Plug the power cord into the AC socket
of the projector.
Reset the lamp timer.
• While simultaneously holding down
MENU/HELPENTER and R on the pro-
jector, press STANDBY/ON on the pro-
jector.
• “LAMP 0000H” is displayed, indicating
that the lamp timer is reset.
• Make sure to reset the lamp timer only when
replacing the lamp. If you reset the lamp timer
and continue to use the same lamp, this may
cause the lamp to become damaged or ex-
plode.
1
2
Info
AC socket
Securing screws
ENTER button
MENU/HELP
button
R button
• If the lamp unit and lamp unit cover are
not correctly installed, the power will not
turn on, even if the power cord is con-
nected to the projector.
Info
STANDBY/ON
button
PGF150X_E_P47_62.p65
07.5.31, 6:30 PM
52
53
Appendix
Connecting Pin Assignments
COMPUTER Input/Output
Pin No.
Signal
  1.
Video input (red)
  2.
Video input (green/sync on green)
  3.
Video input (blue)
  4.
Not connected
  5.
Not connected
  6.
Earth (red)
  7.
Earth (green/sync on green)
  8.
Earth (blue)
  9.
Not connected
10.
GND
11.
Not connected
12.
Bi-directional data
13.
Horizontal sync signal: TTL level
14.
Vertical sync signal: TTL level
15.
Data clock
COMPUTER/COMPONENT input and COMPUTER/COMPONENT output Terminals:mini D-sub 15 pin female
connector
COMPONENT Input/Output
Pin No.
Signal
  1.
PR (CR)
  2.
Y
  3.
PB (CB)
  4.
Not connected
  5.
Not connected
  6.
Earth (PR)
  7.
Earth (Y)
  8.
Earth (PB)
  9.
Not connected
10.
Not connected
11.
Not connected
12.
Not connected
13.
Not connected
14.
Not connected
15.
Not connected
5
10
15
1
11
6
17
24
1
9
16
8
DVI-D Terminal: 24 pin connector
Pin No.
Signal
Pin No.
Signal
  1.
T.M.D.S data 2–
16.
Hot plug detection
  2.
T.M.D.S data 2+
17.
T.M.D.S data 0–
  3.
T.M.D.S data 2 shield
18.
T.M.D.S data 0+
  4.
Not connected
19.
T.M.D.S data 0 shield
  5.
Not connected
20.
Not connected
  6.
DDC clock
21.
Not connected
  7.
DDC data
22.
T.M.D.S clock shield
  8.
Not connected
23.
T.M.D.S clock+
  9.
T.M.D.S data 1–
24.
T.M.D.S clock–
10.
T.M.D.S data 1+
11.
T.M.D.S data 1 shield
12.
Not connected
13.
Not connected
14.
+5V power
15.
Ground
RS-232C Terminal: mini DIN 9 pin female connector
RD
SD
SG
RS
CS
Signal
Name
Pin No.
1.
2.
3.
4.
5.
6.
7.
8.
9.
I/O
Reference
Not connected
Connected to internal circuit
Connected to internal circuit
Not connected
Connected to internal circuit
Not connected
Connected to CS in internal circuit
Connected to RS in internal circuit
Not connected
Receive Data
Send Data
Signal Ground
Request to Send
Clear to Send
Input
Output
8
9
6
5
2
1
4
3
7
PGF150X_E_P47_62.p65
07.5.31, 6:30 PM
53
54
RS-232C Terminal: D-sub 9 pin male connector of the DIN-D-sub RS-232C adaptor
RD
SD
SG
RS
CS
Signal
Name
Pin No.
1.
2.
3.
4.
5.
6.
7.
8.
9.
I/O
Reference
Not connected
Connected to internal circuit
Connected to internal circuit
Not connected
Connected to internal circuit
Not connected
Connected to CS in internal circuit
Connected to RS in internal circuit
Not connected
Receive Data
Send Data
Signal Ground
Request to Send
Clear to Send
Input
Output
1
5
6
9
CD
RD
SD
ER
SG
DR
RS
CS
CI
Signal
Pin No.
1.
2.
3.
4.
5.
6.
7.
8.
9.
RS-232C Cable recommended connection: D-sub 9 pin female connector
CD
RD
SD
ER
SG
DR
RS
CS
CI
Signal
Pin No.
1.
2.
3.
4.
5.
6.
7.
8.
9.
5
1
9
6
• Depending on the controlling device used, it may be necessary to connect Pin 4 and Pin 6 on the
controlling device (e.g. computer).
Note
Projector
Pin No.
4
5
6
Computer
Pin No.
4
5
6
1 2
4 3
USB Terminal:
 
Type B USB connector
VCC
USB–
USB+
SG
Signal
Name
Pin No.
1.
2.
3.
4.
Connecting Pin Assignments (Continued)
USB power
USB data–
USB data+
Signal Ground
PGF150X_E_P47_62.p65
07.5.31, 6:30 PM
54
Page of 68
Display

Click on the first or last page to see other PG-F150X (serv.man5) service manuals if exist.