Projector / Section 2 - Service Manual Text
File
pg-c20xe-sm5.pdf
Date

Sharp PG-C20XE (serv.man5) Service Manual ▷ View online

21
PG-C20XU
PG-C20XE
AN-Z7T
Lamp assembly (bottom view)
Screw B
Screw A
Screw C
D
Adjusting the mirrors
This adjustment is needed when any of the optical parts of the optical mechanism has been replaced.
1. Disconnect the flat cables from all the LCD panels.
2. Light up the lamp.
3. Project a white-light image and check to see if there is any color tint in any direction. If any, loosen the incident-light
fly-eye adjusting plate lock screws and readjust the fly-eye to get the image uniformly whitish. Tighten up the lock
screws.
4. If by any chance the above step 3 fails, use the M1, M4 and M5 adjusting levers.
5. Before moving the M5 adjusting lever, shield the G and B color beams. (For shielding them, use reflective sheets
that reflect the incident lights.)
6. Loosen the adjusting lever lock screws, make adjustments, and tighten up the lock screws.
7.  Before moving the M4 adjusting lever, shield the R and G color beams.
Front
M4 Adjusting lever
Lock screws
(yellow)
Shielding plate for B
Shielding plate for R
Shielding plate for G
M1 Adjusting lever
M5 Adjusting lever
Lock screws
(yellow)
Lock screws
(yellow)
Lock screws
(yellow)
incident-light fly-eye 
adjusting plate
Correcting color irregularities on white-only screen when replacing the lamp
If color irregularities are found at the right and left on a white-only screen after replacing the lamp, it is necessary to
readjust the optical axis of the new lamp. Take the following steps.
1. Open the lamp cover and loosen the screws A, B and C at the bottom of the lamp.
2. Using a screwdriver or the like, move the U-shaped groove at the window D in the arrow direction.
3. Temporarily fix the screws A, B and C, close the lamp cover, and check the white-only screen again for color
irregularities.
4. Repeat the above steps 1, 2 and 3 until there will be no color irregularities. Now tighten up the screws A, B and C.
5. Finally secure the lamp cover back in position.
22
PG-C20XU
PG-C20XE
AN-Z7T
Replacing the prism holder unit
1. Remove the three lock screws, and take the prism holder unit and the projection lens assembly out of the optical
unit.
2. Remove the four lock screws, separate the prism holder unit and the projection lens assembly from each other.
3. Replace the prism holder unit with new one. Take the above steps 1 and 2 in reverse order.
Note: Even if just one of the LCD panels is defective, it is necessary to replace the entire prism holder unit. Do not
replace just the defective LCD panel only.
Projection lens assembly
Prism holder unit
2
Projection lens lock screws (yellow)
B-LCD panel
G-LCD panel
1
Prism holder unit lock screws 
     (yellow)
Optical unit
R-LCD panel
23
PG-C20XU
PG-C20XE
AN-Z7T
ELECTRICAL ADJUSTMENT
Hook up a signal generator, or a DOSV or Mac personal computer to the projector in order to feed the
signals specified in the Adjusting conditions.
1
EEPROM
initialization
1. Turn on the power (with the
lamp on) and warm up the
set for 15 minutes.
2. Select the following group,
sub-group and subject.
Group : Option
Sub-group:
EEPROM Initialize
Subject : Initialize Start
»
Make the following settings.
Press SW1601 to call the process mode. Initialize
the EEPROM by execution of Initialize Start. (After
the execution of Initialize Start, the EEPROM will not
be initialized unless the power is once turned off.)
2
Brightness
adjustment
1. Feed the XGA 10-step sig-
nal.
2. Select the following group,
sub-group and subjects.
Group : Adjust PC Image
Sub-group: AD
Subject :
R-Bright (In R adjustment)
G-Bright (In G adjustment)
B-Bright (In B adjustment)
3. Connect the synchroscope
(0.2V/div.) to the following
TPs.
 In R adjustment  TP1403
 In G adjustment  TP1402
 In B adjustment  TP1401
»
Adjust the setting just until the color tone level 0 starts
moving.
0-gradation
10-gradation
0.8Vp-p
No.
Adjusting point
Adjusting conditions
Adjusting procedure
ADJUSTMENT PRECAUTIONS
1
Precautions for initializing
It takes 5 seconds to get the memory initialized and the initial settings rewritten. To go through the initialization, the
onscreen display background on the process menu screen turns red and the message "INITIALIZE" appears
onscreen for 5 seconds after pressing the specified key. Finally turn off the AC power (unplug the power cord).
2
Initial factory settings (S4, S5)
It takes 5 seconds to get the initial factory settings written. Do not turn off the main power during this procedure. To
ensure this waiting time, "S4" or "S5" appears on the onscreen display for 5 seconds. When this sign disappears,
you can keep on the power or turn it off.
3
Video adjustment
Be careful not to cut off the signals during the video adjustment.
24
No.
Adjusting point
Adjusting conditions
Adjusting procedure
PG-C20XU
PG-C20XE
AN-Z7T
5
Sample hold
pulse phase
checking
»
Feed the G (30%) signal to see if there is no vertical
stripe visible on the screen. If it is visible, adjust the
setting to somewhere between 160 and 200.
Make also sure that the R and B settings are as fol-
lows.
R_CLDLY
171
R_REVCLDLY 175
B_CLDLY
175
B_REVCLDLY 178
1. Feed the XGA mode mono-
chrome signal.
2. Select the following group,
sub-group and subjects.
Group : LCD2(6050)
Sub-group: CLDLY
Subject : R_CLDLY
G_CLDLY
B_CLDLY
R_REVCLDLY
G_REVCLDLY
B_REVCLDLY
2.1Vp-p
3.8Vp-p
4
Panel input
signal amplitude
adjustment
1. Select the following group,
sub-group and subjects.
Group : Adjust PC image
Sub-group: CXA2111R
Subject :
AMP-R-GAIN (In R adjustment)
AMP-R-BLK (In R adjustment)
AMP-G-GAIN (In G adjustment)
AMP-G-BLK (In G adjustment)
AMP-B-GAIN (IN B adjustment)
AMP-B-BLK (IN B adjustment)
2. Connect the synchroscope
to the following TPs.
 In R adjustment  TP1101
 In G adjustment  TP1201
 In B adjustment  TP1301
3. Feed the XGA 10-step sig-
nal.
1.Select AMP-R-GAIN and adjust the signal amplitude
to 3.8 
±
 0.1. Select 0.1Vp-p.
2.Select AMP-R-BLK and adjust the white-white sig-
nal amplitude to 2.1 
±
 0.1Vp-p.
Note: Make sure that the black side does not interfere
in GAIN adjustment.
Adjust the amplitude as for G and B in the same
procedure.
3
Drive adjust-
ment
1. Feed the XGA 10-step sig-
nal.
2. Select the following group,
sub-group and subjects.
Group : Adjust PC Image
Sub-group: AD
Subject :
R-Contrast (In R adjustment)
G-Contrast (In G adjustment)
B-Contrast (In B adjustment)
3. Connect the synchroscope
(0.2V/div.) to the following
TPs.
 In R adjustment  TP1403
 In G adjustment  TP1402
 In B adjustment  TP1401
»
First reach a setting where the color tone level 10
gets saturated. Then decrease the setting by one
point.
0-gradation
10-gradation
0.8Vp-p
Page of 30