Sharp MX-XB17 Service Manual ▷ View online
MX-FX13 FAX SOFT SWITCH 4 - 27
75
1-3
Polarity inversion
settlement time
settlement time
Binary input
Setting range: 200 to 1600ms
Setting range: 200 to 1600ms
200ms
0
0
0
0
4, 5
RCP send number
3 times
0
0
6
Error process in RTN
receive
receive
Error
0
7, 8
RTN send line error
rate
rate
60 lines
1
0
76
1, 2
Timer setting (V.21 -
FSK) between flag -
adrs
FSK) between flag -
adrs
6 sec
0
0
0
3-6
Flag detection byte
number
number
Binary input
4 times
0
1
1
0
0
7, 8
Min. flag number
between frames
between frames
2-flag
0
0
SW
No.
Bit
No.
Item
Switch selection and function
Initial value *
1
Remark
Bit No.
Setting value
1
2
3
0
0
0
200 ms
0
0
1
400 ms
0
1
0
600 ms
0
1
1
800 ms
1
0
0
1000 ms
1
0
1
1200 ms
1
1
0
1400 ms
1
1
1
1600 ms
Bit No.
Setting value
4
5
0
0
3 times
0
1
6 times
1
0
9 times
1
1
12 times
1
Not error
0
Error
Bit No.
Setting value
7
8
0
0
6 lines
0
1
12 lines
1
0
60 lines
1
1
120 lines
Bit No.
Setting value
1
2
0
0
6 sec
0
1
15 sec
1
0
30 sec
1
1
120 sec
Bit No.
Setting
value
3
4
5
6
0
0
0
0
0 time
0
0
0
1
1 time
0
0
1
0
2 times
0
0
1
1
3 times
0
1
0
0
4 times
0
1
0
1
5 times
0
1
1
0
6 times
0
1
1
1
7 times
1
0
0
0
8 times
1
0
0
1
9 times
1
0
1
0
10 times
1
0
1
1
11 times
1
1
0
0
12 times
1
1
0
1
13 times
1
1
1
0
14 times
1
1
1
1
15 times
Bit No.
Setting
value
3
4
5
6
Bit No.
Setting value
7
8
0
0
2-flag
0
1
3-flag
1
0
4-flag
1
1
5-flag
MX-FX13 FAX SOFT SWITCH 4 - 28
77
1-4
Not used
0
1
1
1
1
5, 6
300bps preamble
send time
send time
1.0 sec
0
1
7, 8
Phase C head
dummy data send
time
dummy data send
time
0.3 sec
0
0
0
78
1, 2
CED send start wait
time
time
2.25 sec
0
0
0
3, 4
CED signal send time
3.0 sec
0
0
5, 6
ANSam send start
wait time
wait time
2.25 sec
0
0
7, 8
ANSam signal send
time
time
4.0 sec
0
1
79
1
Time out between
frames
frames
Monitor
1
2
Training
Used to select "Long" or "Short" for the training in the high-speed
transmission in V.17.
If Long/Short setting differs from that in the remote machine, "PPP"
in V.17 occurs.
transmission in V.17.
If Long/Short setting differs from that in the remote machine, "PPP"
in V.17 occurs.
Short training
0
3-8
Not used
0
0
1
1
1
0
1
1
SW
No.
Bit
No.
Item
Switch selection and function
Initial value *
1
Remark
Bit No.
Setting value
5
6
0
0
0.5 sec
0
1
1.0 sec
1
0
1.5 sec
1
1
2.0 sec
Bit No.
Setting value
7
8
0
0
0.3 sec
0
1
0.4 sec
1
0
0.5 sec
1
1
0.2 sec
Bit No.
Setting value
1
2
0
0
2.25 sec
0
1
3.0 sec
1
0
4.0 sec
Bit No.
Setting value
3
4
0
0
3.0 sec
0
1
4.0 sec
1
0
5.0 sec
1
1
6.0 sec
Bit No.
Setting value
5
6
0
0
2.25 sec
0
1
3.0 sec
1
0
4.0 sec
Bit No.
Setting value
7
8
0
0
3.0 sec
0
1
4.0 sec
1
0
5.0 sec
1
1
6.0 sec
1
Monitor
0
Not monitor
1
Long training
0
Short training
MX-FX13 FAX SOFT SWITCH 4 - 29
80
1
Receive wait time
between frames
between frames
3.4 sec
0
2-8
Not used
0
1
0
1
1
0
1
0
0
81
1
Operation in ERR
frame receive
frame receive
Not continue the
process (Error).
process (Error).
0
2-6
Not used
1
1
1
0
0
1
7
V.8 mode CI signal
ON time
ON time
9 byte
0
8
V.8 mode CI signal
OFF time
OFF time
1 sec
0
82
1, 2
Time until resetting
when G3 DIS cannot
be received in V.8
phase.
when G3 DIS cannot
be received in V.8
phase.
When send is made via a satellite, if the DIS signal is not
acknowledged, the receive level is adjusted again and receive is tried
again. This setting is used to set the time until resetting.
acknowledged, the receive level is adjusted again and receive is tried
again. This setting is used to set the time until resetting.
10s
0
1
3
Not used
0
4, 5
Number of times of CI
reception for shifting
to non-V.34
communication
reception for shifting
to non-V.34
communication
Twice
1
0
0
6-8
CI send number for
shifting to non-V.34
communication
shifting to non-V.34
communication
Binary input
Setting range: 0 to 7
When N=0, retrain is not made.
Setting range: 0 to 7
When N=0, retrain is not made.
Twice
0
1
0
83
1-8
Not used
0
0
1
1
1
1
1
1
1
1
84
1-8
Not used
1
1
1
1
1
1
1
1
1
1
1
SW
No.
Bit
No.
Item
Switch selection and function
Initial value *
1
Remark
1
4.4 sec
0
3.4 sec
1
Continues the process.
0
Not continue the process (Error).
1
18 byte
0
9 byte
1
2 sec
0
1 sec
Bit No.
Setting value
1
2
0
0
8s
0
1
10s
1
0
12s
1
1
14s
Bit No.
Setting value
4
5
0
0
Not shift
0
1
Once
1
0
Twice
1
1
3 times
MX-FX13 FAX SOFT SWITCH 4 - 30
85
1-8
Not used
1
1
1
1
1
1
1
1
1
1
1
86
1-8
Not used
0
1
0
0
0
0
1
1
1
0
87
1-8
Not used
0
1
1
0
1
1
1
0
0
0
0
88
1-8
Not used
1
0
0
0
0
0
0
0
0
0
89
1-8
Not used
0
0
1
0
0
1
1
0
0
1
90
1-4
Not used
0
1
1
0
1
5-8
T1 timer setting
Binary input
Setting range: 15 to 90 sec 1step = 5 sec
Setting range: 15 to 90 sec 1step = 5 sec
40 sec
0
1
0
1
1
SW
No.
Bit
No.
Item
Switch selection and function
Initial value *
1
Remark
Bit No.
Setting
value
5
6
7
8
0
0
0
0
15 sec
0
0
0
1
20 sec
0
0
1
0
25 sec
0
0
1
1
30 sec
0
1
0
0
35 sec
0
1
0
1
40 sec
0
1
1
0
45 sec
0
1
1
1
50 sec
1
0
0
0
55 sec
1
0
0
1
60 sec
1
0
1
0
65 sec
1
0
1
1
70 sec
1
1
0
0
75 sec
1
1
0
1
80 sec
1
1
1
0
85 sec
1
1
1
1
90 sec
Bit No.
Setting
value
5
6
7
8