DOWNLOAD Sharp MX-XB17 Service Manual ↓ Size: 1.74 MB | Pages: 80 in PDF or view online for FREE

Model
MX-XB17
Pages
80
Size
1.74 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Service Manual December 2011.
File
mx-xb17.pdf
Date

Sharp MX-XB17 Service Manual ▷ View online

MX-FX13  FAX SOFT SWITCH  4 - 11
33
1
Manual calibration 
when sending
Not executes 
manual 
calibration when 
sending
0
2
Manual calibration 
when receiving
Not executes 
manual 
calibration when 
receiving
0
3
Summer time
Used to set whether the summer time is automatically set or not.
Disable: Other 
than the below 
destinations
Enable: U.K./
Germany/
France/Australia/
New Zealand/
Czech/Slovakia/
Hungary/
Greece/Poland/
Russia
0
4
Not used
0
5, 6
CNG send start time
0.5 sec
0
0
7, 8
Line open delay time 
in dial test
2 sec
0
0
34
1
Sheet count method 
in case of an error
Used to set whether an error page is included in the send quantity 
count in FAX send or not. The default is: an error page is not 
counted.
Send error 
pages are not 
included.
0
2, 3
Time to display 
destination when the 
rapid key is pressed
Binary input
2 sec
0
0
4-8
Signal send level
Binary input
0 (0dBm) to 26 (-26dBm)
0
1
0
1
1
SW
No.
Bit 
No.
Item
Switch selection and function
Initial value *
1
Remark
0 Not executes manual 
calibration when sending
1 Executes manual calibration 
when sending
0 Not executes manual 
calibration when re-ceiving
1 Executes manual calibration 
when receiving
1
Enable
0
Disable
Bit No.
Setting value
5
6
0
0
0.5 sec
0
1
1.0 sec
1
0
1.5 sec
Bit No
Setting value
7
8
0
0
2 sec 
0
1
3 sec 
1
0
4 sec 
1
1
5 sec 
1
Send error pages are 
included.
0
Send error pages are not 
included.
Bit No.
Setting value
2
3
0
0
2 sec
0
1
3 sec
1
0
4 sec
1
1
6 sec
MX-FX13  FAX SOFT SWITCH  4 - 12
35
1
Remained memory 
capacity for receive
128 kbyte
0
2
Polarity inversion 
monitor during 
communication
Fixed to “NO” for North America.
NO
0
3
Polarity inversion 
monitor during call-
out
Fixed to “NO” for North America.
NO
0
4
DPMUTE control
ON: Australia/
New Zealand/
Singapore/
Malaysia/ 
Thailand/India/
Hong Kong
OFF: Other than 
the above 
destinations.
0
5-8
DPMUTE OFF time 
setting after dial
Binary input
Setting range: 0 (5ms) to 15 (80ms)
X (ms) = (N * 5) + 5
5 ms: U.S.A./
Canada/
New Zealand/
Taiwan/
Singapore/
Malaysia/
Thailand/
Middle East/
India/
Hong Kong/
South Africa
65 ms: Australia
50 ms: Other 
than the above 
destinations
0
0
0
0
36
1-4
OFF HOOK  wait time
Binary input
Setting range: 0 (50ms) to 15 (200ms)
X (ms) = (N * 10) + 50
100 ms
0
1
0
1
5-8
Call time setting (TO 
timer setting) in 
automatic send 
When this item is set to a value outside the setting range, it is 
regarded as the initial value. (Menu setting is made in the unit of 
15sec).
Setting range
30 to 35 sec (Russia)
30 to 45 sec (Hong Kong)
30 to 75 sec (Except for Russia/Hong Kong)
15 sec: Russia
45 sec: Except 
for Russia
0
0
1
1
37
1
Report address 
replacement
Print by 
converting the 
name into the 
dial number.
0
2
Report table 
automatic print
NO
0
3
Communication 
report table time 
specification 1
Disable
0
4-8
Time specification 
print (o'clock) 1 on the 
communication report 
table
When this item is set to a value outside the setting range, it is 
regarded as the initial value.
Setting range 0 to 23 o'clock
0 o'clock
0
0
0
0
0
SW
No.
Bit 
No.
Item
Switch selection and function
Initial value *
1
Remark
1
64 kbyte
0
128 kbyte
1
YES
0
NO
1
YES
0
NO
1
ON
0
OFF
1
No conversion
0
Print by converting the 
name into the dial number.
1
YES
0
NO
1
Enable
0
Disable
MX-FX13  FAX SOFT SWITCH  4 - 13
38
1, 2
Sequence of year, 
month, and date in 
LCD, report, and 
sender record
When this item is set to a value outside the setting range, it is 
regarded as the initial value.
Month, Day, 
Year: U.S.A./
Canada/Taiwan
Day, Month, 
Year: Other than 
the above 
destinations
0
1
3-8
Time specification 
print (minute) 1 on the 
communication report 
table
When this item is set to a value outside the setting range, it is 
regarded as the initial value.
Setting range: 0 to 59 min
0 min
0
0
0
0
0
0
39
1, 2
Report output 
(receive)
Print Disable
0
0
3, 4
Report output (send)
When this item is set to a value outside the setting range, it is 
regarded as the initial value.
Only in a send 
error
1
0
5
Report output 
(confidential receive)
Print
1
6, 7
Report output 
(sequential 
broadcast, sequential 
send request, 
interface broadcast 
send)
All print
0
1
8
Report output in 
cancel
Not output
0
40
1, 2
Sent document 
content print in case 
of a memory send 
error
In case of a send 
error
1
0
3
Send document 
content print in F 
code send
SW40 - 1, 2 must be set to output setting. 
Not Print
1
4
Image adding 
function to the report 
table in memory 
confidential send
NO
0
5
Communication 
report total time and 
quantity print
YES
1
6
Report table output 
when in receive 
rejection
Used to set whether the communication report is outputted or not 
when receive is rejected with the receive rejection function. “Output” 
is enabled only when SW11-8 is set to “0”.
Not output
0
SW
No.
Bit 
No.
Item
Switch selection and function
Initial value *
1
Remark
Bit No.
Setting value
1
2
0
0
Year, Month, Day
0
1
Month, Day, Year
1
0
Day, Month, Year
Bit No.
Setting value
1
2
0
0
Print  Disable
0
1
All print
1
0
Only in an error
Bit No.
Setting value
3
4
0
0
Print  Disable
0
1
All print
1
0
Only in a send error
1
Print
0
Not print
Bit No.
Setting value
6
7
0
0
Print Disable
0
1
All print
1
0
Only for the destination of send error
1
Output
0
Not output
Bit No.
Setting value
1
2
0
0
Not print
0
1
All print
1
0
In case of a send error
1
Not print
0
Print
1
YES
0
NO
1
YES
0
NO
1
Output
0
Not output
MX-FX13  FAX SOFT SWITCH  4 - 14
40
7
Time display format
AM/PM: U.S.A./
Canada/Taiwan
24H: Other than 
the above 
destinations
1
8
Display with priority 
on the day of the 
week
NO
0
41
1
Protocol monitor
NO
0
2
Output only in case of 
an error of the 
protocol monitor
In case of "1: YES," set SW41-1 to "1: YES" together.
NO
0
3
Protocol monitor save
Save
1
4, 5
Line sound monitor 
range
When this item is set to a value outside the setting range, it is 
regarded as the initial value.
Up to send/
receive of NSF 
signal
0
1
6
Line monitor display
NO
0
7, 8
Not used
0
0
42
1-3
Silicon DAA mute 
boot time
Binary input
3.5 sec
0
0
0
4
Print hold key 
operation
Used to set whether print hold is enabled or disabled with the key 
operation.
Disable
0
5
Print hold function
Used to set whether the print hold function is enabled or disabled 
with the function menu. To enable, the setting (SW42-4) in the key 
operation must be allowed.
OFF
0
6
Automatic reduction 
print
Enable
1
7
Paper selection 
priority order
Priority on the 
area
0
8
Report output to 
paper smaller than A4 
(LTR)
Reduced by the 
specified value.
0
SW
No.
Bit 
No.
Item
Switch selection and function
Initial value *
1
Remark
1
AM/PM
0
24H
1
YES
0
NO
1
YES
0
NO
1
YES
0
NO
1
Save
0
Disable
Bit No.
Setting value
4
5
0
0
OFF
0
1
Up to send/receive of NSF signal
1
0
All
1
YES
0
NO
Bit No.
Setting value
1
2
3
0
0
0
3.5 sec
0
0
1
3.0 sec
0
1
0
2.5 sec
0
1
1
2.0 sec
1
0
0
1.5 sec
1
0
1
1.0 sec
1
1
0
0.5 sec
1
1
1
No boot
1
Enable
0
Disable
1
ON
0
OFF
1
Enable
0
Disable
1
Priority on the width
0
Priority on the area
1
Reduced as an A4 
(LTR) image.
0
Reduced by the 
specified value.
Page of 80
Display