DOWNLOAD Sharp MX-XB17 Service Manual ↓ Size: 1.74 MB | Pages: 80 in PDF or view online for FREE

Model
MX-XB17
Pages
80
Size
1.74 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Service Manual December 2011.
File
mx-xb17.pdf
Date

Sharp MX-XB17 Service Manual ▷ View online

MX-FX13  FAX SOFT SWITCH  4 - 7
21
1-4
Minimum pause time 
(10PPS) setting
Binary input
0 (525ms) to 15 (900ms)
X (ms) = (N * 25) + 525
650 ms: 
Middle East/
Hong Kong
750 ms: U.S.A./
Canada
800 ms: 
Thailand/India
875 ms: 
Australia/New 
Zealand/Taiwan/
Singapore/
Malaysia/
South Africa
825 ms: Other 
then the above 
destinations
1
0
0
1
5-8
Make time (10PPS) 
setting
Binary input
Setting range: 26 to 41ms
1ms interval
X (ms) = N + 26ms
29 ms: Australia
33 ms: 
New Zealand/
Taiwan/
Singapore/
Malaysia/India/
Hong Kong/
South Africa
34 ms: U.K./
France/
Netherlands/
Luxembourg/
Belgium
38 ms: Thailand
39 ms: Russia
40 ms: U.S.A./
Canada/
Middle East
41 ms: Other 
than the above 
destinations
1
1
1
0
22
1-5
Before-dial time 
(10PPS) setting
Binary input
Setting range: 0 (50ms) to 31 (360ms)
X (ms) = (N * 10) + 50
60 ms: U.S.A./
Canada/
New Zealand/
Taiwan/
Singapore/ 
Malaysia/
Thailand/
Middle East/
India/Hong Kong 
/South Africa
250 ms: 
Australia
300 ms: Other 
than the above 
destinations
0
0
0
0
1
6-8
Minimum pause time 
(20PPS) setting
Binary input
375 ms
0
0
0
SW
No.
Bit 
No.
Item
Switch selection and function
Initial value *
1
Remark
Bit No.
Setting value
6
7
8
0
0
0
375  ms
0
0
1
400  ms
0
1
0
425  ms
0
1
1
450  ms
1
0
0
475  ms
1
0
1
500  ms
1
1
0
525  ms
1
1
1
550  ms
MX-FX13  FAX SOFT SWITCH  4 - 8
23
1-4
Make time (20PPS) 
setting
Binary input
Setting range: 9 to 24 ms
1ms interval
9 (Fixed)
0
0
0
0
5-7
Before-dial time 
(20PPS) setting
50 ms
0
0
0
8
DP dial pulse number 
process
10 - N: New 
Zealand
Normal (N): 
Except for New 
Zealand
0
24
1-5
DTMF signal send 
time
Binary input
6 (60ms) to 31 (310ms)
X (ms) = (N * 10)
80 ms: U,K./
Germany/
France/Sweden/
Spain/Portugal/ 
Italy/
Switzerland/
Finland/
Denmark/
Norway/
Netherlands/
Luxembourg/
Belgium/Czech/
Slovakia/
Hungary/
Greece/Poland
110 ms: Other 
than the above 
destinations
0
1
0
1
1
6-8
Minimum pause time 
(DTMF) setting
Binary input
Setting range: 90ms to 160ms
120 ms
0
1
1
SW
No.
Bit 
No.
Item
Switch selection and function
Initial value *
1
Remark
Bit No.
Setting value
5
6
7
0
0
0
50  ms
0
0
1
60  ms
0
1
0
70  ms
0
1
1
80  ms
1
0
0
90  ms
1
0
1
100 ms
1
1
0
110 ms
1
1
1
120 ms
1
10 - N
0
Normal (N)
Bit No.
Setting value
6
7
8
0
0
0
90 ms
0
0
1
100 ms
0
1
0
110 ms
0
1
1
120 ms
1
0
0
130 ms
1
0
1
140 ms
1
1
0
150 ms
1
1
1
160 ms
MX-FX13  FAX SOFT SWITCH  4 - 9
25
1
Dial start wait time
3.5 sec
0
0
3-5
Before-dial time 
(DTMF) setting
Binary input
Setting rage: 30ms to 100ms
50 ms
0
1
0
6, 7
Tone/pulse default 
setting
TONE
1
0
8
Not used
0
26
1
RTC error adjustment
Used to correct advancement of the clock. The default is No 
Correction.
Not adjusts error
0
2, 3
Not used
0
0
4
Dial tone detection
YES: Singapore
NO: Except for 
Singapore
0
5
Not used
0
6
Dial tone ON/OFF 
detection time upper 
limit
Used to set the upper limit of the dial tone ON/OFF detection time.
700 ms
0
7
Dial tone ON/OFF 
detection time lower 
limit
Used to set the lower limit of the dial tone ON/OFF detection time. 
100 ms
0
8
Not used
0
27
1-4
Outside line 
connection number 
setting 1 (1st digit)
Binary input
0
0
0
0
5-8
Outside line 
connection number 
setting 1 (2nd digit)
Binary input
For Bit No., refer to the table of SW27-(1 - 4).
0
0
0
0
SW
No.
Bit 
No.
Item
Switch selection and function
Initial value *
1
Remark
Bit No.
Setting value
1
2
0
0
3.5 sec
0
1
4 sec
1
0
5 sec
1
1
6 sec 
Bit No.
Setting value
3
4
5
0
0
0
30  ms
0
0
1
40  ms
0
1
0
50  ms
0
1
1
60  ms
1
0
0
70  ms
1
0
1
80  ms
1
1
0
90  ms
1
1
1
100 ms
Bit No.
Setting value
6
7
0
0
10 PPS
0
1
20 PPS
1
0
TONE
1
 Adjusts error
0
Not adjusts error
1
YES
0
NO
1
1200 ms
0
700 ms
1
70 ms
0
100 ms
Bit No.
Setting 
value
1
2
3
4
0
0
0
0
0
0
0
0
1
1
0
0
1
0
2
0
0
1
1
3
0
1
0
0
4
0
1
0
1
5
0
1
1
0
6
Bit No.
Setting 
value
1
2
3
4
0
1
1
1
7
1
0
0
0
8
1
0
0
1
9
1
0
1
0
*
1
0
1
1
#
1
1
0
0
-  (Pause)
MX-FX13  FAX SOFT SWITCH  4 - 10
28
1-4
Outside line 
connection number 
setting 1 (3rd digit)
Binary input
For Bit No., refer to the table of SW27.
0
0
0
0
5-8
Outside line 
connection number 
setting 1 (4th digit)
Binary input
For Bit No., refer to the table of SW27.
0
0
0
0
29
1-4
Outside line 
connection number 
setting 2 (1st digit)
Binary input
For Bit No., refer to the table of SW27.
0
0
0
0
5-8
Outside line 
connection number 
setting 2 (2nd digit)
Binary input
For Bit No., refer to the table of SW27.
0
0
0
0
30
1-4
Outside line 
connection number 
setting 2 (3rd digit)
Binary input
For Bit No., refer to the table of SW27.
0
0
0
0
5-8
Outside line 
connection number 
setting 2 (4th digit)
Binary input
For Bit No., refer to the table of SW27.
0
0
0
0
31
1
External auditor 
check
Used to set whether Enable/Disable of the FAX department 
management when an external auditor is used. The default is 
Disable.
Check
0
2
Busy tone detection
YES
1
3, 4
Busy tone detection 
frequency
2 pulses
0
0
5
Not used
0
6, 7
Busy tone detection 
level
-43 dB
0
0
8
CED detection time
1000 ms
0
32
1-4
CNG detection time
Binary input
Setting range: 0 to 15 sec 
0 sec (Fixed)
0
0
0
0
5-8
Pause time setting
When this item is set to a value outside the setting range, it is 
regarded as the initial value.
Binary input
Setting range
1 to 15sec (Except for South Africa)
4 to 15 (South Africa)
2 sec: Except for 
South Africa
4 sec: South 
Africa
0
0
1
0
SW
No.
Bit 
No.
Item
Switch selection and function
Initial value *
1
Remark
1
Not check
0
Check
1
YES
0
NO
Bit No.
Setting value
3
4
0
0
2 pulses
0
1
4 pulses
1
0
6 pulses
1
1
10 pulses
Bit No.
Setting value
6
7
0
0
-43 dB
0
1
-35 dB
1
0
-33 dB
1
1
-30 dB
1
500 ms
0
1000 ms
Page of 80