Sharp MX-XB17 Service Manual ▷ View online
MX-FX13 FAX SOFT SWITCH 4 - 7
21
1-4
Minimum pause time
(10PPS) setting
(10PPS) setting
Binary input
0 (525ms) to 15 (900ms)
X (ms) = (N * 25) + 525
0 (525ms) to 15 (900ms)
X (ms) = (N * 25) + 525
650 ms:
Middle East/
Hong Kong
Middle East/
Hong Kong
750 ms: U.S.A./
Canada
Canada
800 ms:
Thailand/India
Thailand/India
875 ms:
Australia/New
Zealand/Taiwan/
Singapore/
Malaysia/
South Africa
Australia/New
Zealand/Taiwan/
Singapore/
Malaysia/
South Africa
825 ms: Other
then the above
destinations
then the above
destinations
1
0
0
0
1
5-8
Make time (10PPS)
setting
setting
Binary input
Setting range: 26 to 41ms
1ms interval
Setting range: 26 to 41ms
1ms interval
X (ms) = N + 26ms
29 ms: Australia
33 ms:
New Zealand/
Taiwan/
Singapore/
Malaysia/India/
Hong Kong/
South Africa
New Zealand/
Taiwan/
Singapore/
Malaysia/India/
Hong Kong/
South Africa
34 ms: U.K./
France/
Netherlands/
Luxembourg/
Belgium
France/
Netherlands/
Luxembourg/
Belgium
38 ms: Thailand
39 ms: Russia
40 ms: U.S.A./
Canada/
Middle East
Canada/
Middle East
41 ms: Other
than the above
destinations
than the above
destinations
1
1
1
1
0
22
1-5
Before-dial time
(10PPS) setting
(10PPS) setting
Binary input
Setting range: 0 (50ms) to 31 (360ms)
X (ms) = (N * 10) + 50
Setting range: 0 (50ms) to 31 (360ms)
X (ms) = (N * 10) + 50
60 ms: U.S.A./
Canada/
New Zealand/
Taiwan/
Singapore/
Malaysia/
Thailand/
Middle East/
India/Hong Kong
/South Africa
Canada/
New Zealand/
Taiwan/
Singapore/
Malaysia/
Thailand/
Middle East/
India/Hong Kong
/South Africa
250 ms:
Australia
Australia
300 ms: Other
than the above
destinations
than the above
destinations
0
0
0
0
0
1
6-8
Minimum pause time
(20PPS) setting
(20PPS) setting
Binary input
375 ms
0
0
0
SW
No.
Bit
No.
Item
Switch selection and function
Initial value *
1
Remark
Bit No.
Setting value
6
7
8
0
0
0
375 ms
0
0
1
400 ms
0
1
0
425 ms
0
1
1
450 ms
1
0
0
475 ms
1
0
1
500 ms
1
1
0
525 ms
1
1
1
550 ms
MX-FX13 FAX SOFT SWITCH 4 - 8
23
1-4
Make time (20PPS)
setting
setting
Binary input
Setting range: 9 to 24 ms
1ms interval
Setting range: 9 to 24 ms
1ms interval
9 (Fixed)
0
0
0
0
0
5-7
Before-dial time
(20PPS) setting
(20PPS) setting
50 ms
0
0
0
8
DP dial pulse number
process
process
10 - N: New
Zealand
Zealand
Normal (N):
Except for New
Zealand
Except for New
Zealand
0
24
1-5
DTMF signal send
time
time
Binary input
6 (60ms) to 31 (310ms)
X (ms) = (N * 10)
6 (60ms) to 31 (310ms)
X (ms) = (N * 10)
80 ms: U,K./
Germany/
France/Sweden/
Spain/Portugal/
Italy/
Switzerland/
Finland/
Denmark/
Norway/
Netherlands/
Luxembourg/
Belgium/Czech/
Slovakia/
Hungary/
Greece/Poland
Germany/
France/Sweden/
Spain/Portugal/
Italy/
Switzerland/
Finland/
Denmark/
Norway/
Netherlands/
Luxembourg/
Belgium/Czech/
Slovakia/
Hungary/
Greece/Poland
110 ms: Other
than the above
destinations
than the above
destinations
0
1
0
1
1
1
6-8
Minimum pause time
(DTMF) setting
(DTMF) setting
Binary input
Setting range: 90ms to 160ms
Setting range: 90ms to 160ms
120 ms
0
1
1
1
SW
No.
Bit
No.
Item
Switch selection and function
Initial value *
1
Remark
Bit No.
Setting value
5
6
7
0
0
0
50 ms
0
0
1
60 ms
0
1
0
70 ms
0
1
1
80 ms
1
0
0
90 ms
1
0
1
100 ms
1
1
0
110 ms
1
1
1
120 ms
1
10 - N
0
Normal (N)
Bit No.
Setting value
6
7
8
0
0
0
90 ms
0
0
1
100 ms
0
1
0
110 ms
0
1
1
120 ms
1
0
0
130 ms
1
0
1
140 ms
1
1
0
150 ms
1
1
1
160 ms
MX-FX13 FAX SOFT SWITCH 4 - 9
25
1
Dial start wait time
3.5 sec
0
0
0
3-5
Before-dial time
(DTMF) setting
(DTMF) setting
Binary input
Setting rage: 30ms to 100ms
Setting rage: 30ms to 100ms
50 ms
0
1
0
6, 7
Tone/pulse default
setting
setting
TONE
1
0
0
8
Not used
0
26
1
RTC error adjustment
Used to correct advancement of the clock. The default is No
Correction.
Correction.
Not adjusts error
0
2, 3
Not used
0
0
4
Dial tone detection
YES: Singapore
NO: Except for
Singapore
Singapore
0
5
Not used
0
6
Dial tone ON/OFF
detection time upper
limit
detection time upper
limit
Used to set the upper limit of the dial tone ON/OFF detection time.
700 ms
0
7
Dial tone ON/OFF
detection time lower
limit
detection time lower
limit
Used to set the lower limit of the dial tone ON/OFF detection time.
100 ms
0
8
Not used
0
27
1-4
Outside line
connection number
setting 1 (1st digit)
connection number
setting 1 (1st digit)
Binary input
0
0
0
0
0
5-8
Outside line
connection number
setting 1 (2nd digit)
connection number
setting 1 (2nd digit)
Binary input
For Bit No., refer to the table of SW27-(1 - 4).
0
0
0
0
0
SW
No.
Bit
No.
Item
Switch selection and function
Initial value *
1
Remark
Bit No.
Setting value
1
2
0
0
3.5 sec
0
1
4 sec
1
0
5 sec
1
1
6 sec
Bit No.
Setting value
3
4
5
0
0
0
30 ms
0
0
1
40 ms
0
1
0
50 ms
0
1
1
60 ms
1
0
0
70 ms
1
0
1
80 ms
1
1
0
90 ms
1
1
1
100 ms
Bit No.
Setting value
6
7
0
0
10 PPS
0
1
20 PPS
1
0
TONE
1
Adjusts error
0
Not adjusts error
1
YES
0
NO
1
1200 ms
0
700 ms
1
70 ms
0
100 ms
Bit No.
Setting
value
1
2
3
4
0
0
0
0
0
0
0
0
1
1
0
0
1
0
2
0
0
1
1
3
0
1
0
0
4
0
1
0
1
5
0
1
1
0
6
Bit No.
Setting
value
1
2
3
4
0
1
1
1
7
1
0
0
0
8
1
0
0
1
9
1
0
1
0
*
1
0
1
1
#
1
1
0
0
- (Pause)
MX-FX13 FAX SOFT SWITCH 4 - 10
28
1-4
Outside line
connection number
setting 1 (3rd digit)
connection number
setting 1 (3rd digit)
Binary input
For Bit No., refer to the table of SW27.
0
0
0
0
0
5-8
Outside line
connection number
setting 1 (4th digit)
connection number
setting 1 (4th digit)
Binary input
For Bit No., refer to the table of SW27.
0
0
0
0
0
29
1-4
Outside line
connection number
setting 2 (1st digit)
connection number
setting 2 (1st digit)
Binary input
For Bit No., refer to the table of SW27.
0
0
0
0
0
5-8
Outside line
connection number
setting 2 (2nd digit)
connection number
setting 2 (2nd digit)
Binary input
For Bit No., refer to the table of SW27.
0
0
0
0
0
30
1-4
Outside line
connection number
setting 2 (3rd digit)
connection number
setting 2 (3rd digit)
Binary input
For Bit No., refer to the table of SW27.
0
0
0
0
0
5-8
Outside line
connection number
setting 2 (4th digit)
connection number
setting 2 (4th digit)
Binary input
For Bit No., refer to the table of SW27.
0
0
0
0
0
31
1
External auditor
check
check
Used to set whether Enable/Disable of the FAX department
management when an external auditor is used. The default is
Disable.
management when an external auditor is used. The default is
Disable.
Check
0
2
Busy tone detection
YES
1
3, 4
Busy tone detection
frequency
frequency
2 pulses
0
0
5
Not used
0
6, 7
Busy tone detection
level
level
-43 dB
0
0
0
8
CED detection time
1000 ms
0
32
1-4
CNG detection time
Binary input
Setting range: 0 to 15 sec
Setting range: 0 to 15 sec
0 sec (Fixed)
0
0
0
0
0
5-8
Pause time setting
When this item is set to a value outside the setting range, it is
regarded as the initial value.
Binary input
Setting range
1 to 15sec (Except for South Africa)
4 to 15 (South Africa)
regarded as the initial value.
Binary input
Setting range
1 to 15sec (Except for South Africa)
4 to 15 (South Africa)
2 sec: Except for
South Africa
4 sec: South
Africa
South Africa
4 sec: South
Africa
0
0
1
0
0
SW
No.
Bit
No.
Item
Switch selection and function
Initial value *
1
Remark
1
Not check
0
Check
1
YES
0
NO
Bit No.
Setting value
3
4
0
0
2 pulses
0
1
4 pulses
1
0
6 pulses
1
1
10 pulses
Bit No.
Setting value
6
7
0
0
-43 dB
0
1
-35 dB
1
0
-33 dB
1
1
-30 dB
1
500 ms
0
1000 ms
Click on the first or last page to see other MX-XB17 service manuals if exist.