C
ALIBRATION
57
13 When the Status field indicates that all four color strips have been read successfully, click 
Accept Measurements.
14 Click OK in the Measure dialog box.
15 Click Apply in the Calibrator dialog box to implement the new calibration set.
16 Click OK in the Information dialog box.
This completes the Fiery X3eTY2 calibration process.
Calibrating with the ED-100
 
Use ColorWise Pro Tools in conjunction with the ED-100 to calibrate the Fiery X3eTY2.
N
OTE
You must calibrate the MFP every time you use the ED-100.
T
O
 
CALIBRATE
 
THE
 F
IERY 
X3
E
TY2 
USING
 
THE
 ED-100
1 Start Calibrator.
For instructions on starting Calibrator, see 
page 46
.
2 Choose EFI Densitometer ED-100 as the measurement method.
3 In the Check Print Settings pane, choose a calibration set.
If more than one option appears, choose the appropriate calibration set for the type of media 
you use most often.
N
OTE
For this calibration to take effect, the calibration set must be associated with one or 
more output profiles. The default calibration set is already associated with the default output 
profile, so there is no need to make any new associations.
4 In the Generate Measurement Page pane, click Print.
The Print Options dialog box appears.
C
ALIBRATION
58
5 Choose the appropriate options and click Print.
Page Type:
 Choose either 34 or 21 Sorted Patches, or 34 or 21 Randomized Patches. Sorted 
patches are printed on the page in the order of their hue and saturation levels. Randomized 
patches are printed on the page in random order, to help compensate for density 
inconsistencies on different areas of the page.
Paper Size:
 Automatically set to LTR/A4 for 21 patches. Choose 11
x
17/A3 or 
12
x
18/SRA3 for 34 patches. 
Input Tray:
 Specify the paper source for printing the measurement page.
6 Retrieve the measurement page from the MFP.
7 Click Measure in the Get Measurements pane.
The Measurement Options dialog box appears.
8 Choose the appropriate options, and then click Start.
Page Type is automatically set to the measurement page type that you printed in 
step 5
.
Use the arrow buttons next to the Clicks Per Patch field to choose the number of 
measurements you want to take for each patch on the page. When you choose multiple clicks, 
the average value of all measurements taken for the patch is returned to the Fiery X3eTY2. 
Multiple measurements are more accurate, but may take more time.
To hear a confirmation tone each time a measurement is recorded, select the Audio Feedback 
option. A single tone indicates a successful measurement. Two tones indicate a measurement 
error. If you have specified multiple clicks per patch, the tone sounds after you take the final 
measurement.
C
ALIBRATION
59
If necessary, choose the appropriate COM port for the ED-100 from the Port menu.
When you click Start, the Measurements window appears. Directions for measuring the 
patches appear in the Status area.
9 Place the ED-100 over the specified patch on the Measurement Page, making sure to center 
the sample aperture over the patch. Press Measure to take the measurement.
N
OTE
For a more accurate measurement, place several plain sheets of paper beneath the 
Measurement Page to block underlying colors from being read by the instrument.
If you have specified multiple clicks per patch, continue pressing Measure to take the required 
number of measurements. We recommend that you move the ED-100 slightly after each 
measurement while keeping it within the patch circle.
When the patch has been measured successfully, a check mark appears in the patch preview in 
the Measurements window. The window identifies and highlights the next patch to be 
measured.
C
ALIBRATION
60
10 Repeat 
step 9
 to measure each successive patch on the Measurement Page.
Start with A1 and continue down Column A. When you have finished measuring all the 
patches in Column A, proceed to Column B in the same manner until all columns have been 
measured.
To retake a measurement, select the desired patch preview in the Measurements window and 
measure the patch on the page using the ED-100.
N
OTE
You must take the measurements in the order outlined in the Measurements window 
and on the measurement page.
11 When all the patches have been read successfully, click Accept.
12 Click Apply in the Calibrator dialog box.
The new calibration measurement is implemented.
13 Click OK in the Information dialog box.
This completes the Fiery X3eTY2 calibration process.
Calibrating with the ES-1000
Use ColorWise Pro Tools in conjunction with the ES-1000 spectrophotometer to calibrate 
the Fiery X3eTY2.
N
OTE
Before you use ColorWise Pro Tools and the ES-1000 to calibrate the 
Fiery X3eTY2, follow the instructions on 
page 97
 to set up and calibrate the ES-1000.
T
O
 
CALIBRATE
 
THE
 F
IERY 
X3
E
TY2 
USING
 
THE
 ES-1000
1 Start Calibrator.
For instructions, see 
page 46
.
2 Choose ES-1000 as the measurement method.
3 In the Check Print Settings pane, choose a calibration set.
If more than one option appears, choose the appropriate calibration set for the type of media 
you use most often.
N
OTE
For this calibration to take effect, the calibration set must be associated with one or 
more output profiles. The default calibration set is already associated with the default output 
profile. You do not need to make any new associations.
4 Click Print in the Generate Measurement Page pane.
The Print Options dialog box appears.
Page of 104