C
ALIBRATION
45
About this chapter
This chapter describes the procedures for calibrating the Fiery X3eTY2 using ColorWise Pro 
Tools Calibrator with various color measurement instruments or calibrating from the MFP 
touch panel. The following table provides the location of each procedure.
This chapter also describes important concepts and suggestions for understanding calibration. 
The following table provides the location of each description. 
N
OTE
The procedures described in this chapter are fundamentally the same for Windows and 
Mac OS computers. Illustrations from a Windows computer are used in this chapter.
Calibration method
See
ColorCal with Calibrator
page 49
DTP32 or DTP32 Series II with Calibrator
page 52
DTP41 with Calibrator
page 54
ED-100 with Calibrator
page 57
ES-1000 with Calibrator
page 60
ColorCal from the MFP touch panel
page 64
For more information about
See
An overview of calibration
page 66
How calibration works
page 66
Scheduling calibration
page 68
Checking calibration status
page 68
C
ALIBRATION
46
Calibrating with ColorWise Pro Tools Calibrator
ColorWise Pro Tools Calibrator allows you to calibrate the Fiery X3eTY2 using the 
measurement method of your choice.
Changing calibration has the potential to affect all jobs for all users, so consider limiting the 
number of people authorized to perform calibration. Set an Administrator password to 
control access to calibration (see 
Configuration and Setup
).
N
OTE
Multiple users can be connected to one Fiery X3eTY2 with ColorWise Pro Tools, but 
only one user at a time can use Calibrator. If you try to calibrate when another user is using 
ColorWise Pro Tools to calibrate, an error message appears.
Starting Calibrator
Start Calibrator from the ColorWise Pro Tools main window.
T
O
 
CALIBRATE
 
THE
 F
IERY 
X3
E
TY2 
USING
 C
ALIBRATOR
1 Start ColorWise Pro Tools and connect to the Fiery X3eTY2.
For information about configuring the connection to the Fiery X3eTY2, see pages 
14
 
and 
18
.
2 Click Calibrator.
C
ALIBRATION
47
3 Choose a method from the Select Measurement Method menu.
Procedures for each calibration method are described in subsequent sections of this chapter.
Expert mode
Calibrator provides two modes: Standard and Expert. You can perform all essential calibration 
tasks while in Standard mode. Expert mode offers two additional options: Print Pages and 
View Measurements.
1
Calibration methods
1
1
Calibration methods
1
C
ALIBRATION
48
With the Print Pages option, print Comparison Pages showing the results of the new 
measurements with any profile associated with the currently selected calibration set. You can 
create a custom Comparison Page and save it as a PostScript or Encapsulated PostScript (EPS) 
file called CALIB.PS. Next, print the file to the Hold queue of the Fiery X3eTY2 from your 
application. You can also create a CALIB.PS file by renaming any job in the Hold queue using 
Command WorkStation (see 
Utilities
).
With the View Measurements option, you can view the current set of measurements as a table 
or graph that shows both the measurements and the target curves.
When more than one profile uses the same target, an additional menu called Plot Against 
appears in the upper-right corner of the dialog box. It lists all output profiles that use that 
same calibration set. Selecting an output profile from this menu displays the target curves 
associated with that profile. If each output profile contains a unique calibration target, the 
curves displayed also change when you switch profiles.
1
Output profile name
1
Page of 104