Sharp MX-M905 (serv.man2) Service Manual ▷ View online
MX-M905 ADJUSTMENTS 5 – 85
<Descriptions of keys>
<Result display>
21-B
CCD gamma adjustment (CCD calibration)
(DSPF mode)
(DSPF mode)
This adjustment is required in the following cases:
* When the DSPF CCD unit is replaced.
* When a U2 trouble occurs.
* When the DSPF control PWB is replaced.
(1) Note before adjustment
1)
Check to insure that there is no dirt or dust on the DSPF scan-
ning glass, the mirror, and the lens surface. (If there is, clean it
with alcohol.)
ning glass, the mirror, and the lens surface. (If there is, clean it
with alcohol.)
2)
Check to confirm that the patches in BK1 and BK2 arrays of
the SIT chart (UKOG-0356) are free from dirt and scratches.
the SIT chart (UKOG-0356) are free from dirt and scratches.
If they are dirty, clean them.
If they are scratched or streaked, replace with new one.
NOTE:
Since the SIT chart is easily discolored by sunlight (especially ultra-
violet rays) and humidity and temperature, put it in a bag such as a
clear file) and store in a dark place of low temperature and low
humidity.
violet rays) and humidity and temperature, put it in a bag such as a
clear file) and store in a dark place of low temperature and low
humidity.
(2) Adjustment procedures
1)
Set the SIT chart (UKOG-0356) face-down in the DSPF paper
feed tray.
feed tray.
If the SIT chart is not available, execute SIM 63-5 to set the
CCD gamma to the default. In this case, however, the adjust-
ment accuracy is lower when compared with the adjustment
method using the SIT chart.
CCD gamma to the default. In this case, however, the adjust-
ment accuracy is lower when compared with the adjustment
method using the SIT chart.
2)
Enter the SIM 63-3 mode.
3)
When a color key is selected, the adjustment value of the
selected color is displayed.
selected color is displayed.
* When [B] (Blue), [G] (Green), or [R] (Red) key is selected,
the selected key is highlighted and the adjustment value of
the selected color is displayed.
the selected color is displayed.
* Only one color key can be selected, and the selected key is
highlighted. In the initial state, [B] is selected.
* If there is a page over [
], an active display is shown and the
page moves up. If there is no page upward, the display
grays out and the operation is invalid.
grays out and the operation is invalid.
If there is a page under [
], an active display is shown and
the page moves down. If there is no page downward, the
display grays out and the operation is invalid.
display grays out and the operation is invalid.
4)
When [DSPF] key is pressed, it is highlighted, and the color
automatic adjustment execution screen is displayed.
automatic adjustment execution screen is displayed.
5)
Press [EXECUTE] key and it is highlighted and the color auto
adjustment is executed.
adjustment is executed.
* When [EXECUTE] key is pressed during the automatic
adjustment, the automatic adjustment is interrupted.
6)
After normal completion, the result of calculation is displayed
in the initial screen.
in the initial screen.
* When an error occurs in execution, the following screen is dis-
played.
* When an error occurs in the automatic adjustment, all the error
patch numbers are displayed.
When [RESULT] key is pressed, the display returns to the initial
screen. (The previous value is displayed)
screen. (The previous value is displayed)
* When the operation is completed normally, "COMPLETE" is dis-
played. When [RESULT] key is pressed, the display returns to
the initial screen. (The calculation result of normal completion is
displayed.)
the initial screen. (The calculation result of normal completion is
displayed.)
Display
Content
OC
SHADING
SHADING
OC analog correction level correction, and shading
correction data making (Document table mode)
correction data making (Document table mode)
DSPF
SHADING
SHADING
Analog correction level correction, and shading correction
data making (DSPF mode)
data making (DSPF mode)
Display
Content
COMPLETE
Normal completion
ERROR
Abnormal completion
INCOMPLETE
Incomplete, interruption
MX-M905 SIMULATION 6 – 1
MX-M905
Service Manual
[6] SIMULATION
1. General and purpose
The simulation mode has the following functions, to display the
machine operating status, identify the trouble position and causes
in an earlier stage and to efficiently setup and adjust the machine
for improved serviceability.
1) Various adjustments
2) Setting of the specifications and functions
3) Canceling troubles
4) Operation check
5) Counters check, setting clear
6) Machine operating conditions (operation hysteresis) data
machine operating status, identify the trouble position and causes
in an earlier stage and to efficiently setup and adjust the machine
for improved serviceability.
1) Various adjustments
2) Setting of the specifications and functions
3) Canceling troubles
4) Operation check
5) Counters check, setting clear
6) Machine operating conditions (operation hysteresis) data
check, clear
7) Various (adjustments, setting, operation, counters, etc) data
transport.
The operating procedures and displays depend on the design of
the operation panel of the machine.
the operation panel of the machine.
There are two simulation modes.
* Easy mode:
* Easy mode:
Displays commonly used simulations for each category, allowing
easy access for technicians to change settings, perform mainte-
nance and adjustments.
easy access for technicians to change settings, perform mainte-
nance and adjustments.
* Classic mode:
All simulations are listed and can be accessed by entering the
main code, then sub code as per previous model series.
main code, then sub code as per previous model series.
2. Function of each key
3. Starting the simulation
Entering the simulation mode.
1) Double-click the HOME key
2) Touch the Ver display section (10-key mode input mode
1) Double-click the HOME key
2) Touch the Ver display section (10-key mode input mode
screen)
3)
Touch the (#) key → Asterisk (*) key → Clear key → Asterisk
(*) key → Ready for input of main code of simulation.
(*) key → Ready for input of main code of simulation.
No.
Name
Function
1
TEST key
Change test mode
2
Mode setting key
Change Easy mode, Classic mode
3
Language setting key
Change language in simulation mode
4
INFO key
Display operation of current display
5
EXIT key
Exit from simulation mode
6
BACK key
Back to the previous display
7
Clear key
Clear input value
1
2 3 4
5
6
7
Ver
MX-M905 SIMULATION 6 – 2
4. List of simulation codes
A. List of classic mode
Main
Sub
Function (Purpose)
Section
Purpose
1
1
Used to check the operation of the scanner (reading) unit and the control circuit.
Scanner (reading)
Operation test/check
2
Used to check the sensors in the scanner (reading) section and the related circuits.
Scanner (reading)
Operation test/check
5
Used to check the operation of the scanner (reading) unit and the control circuit.
Scanner (reading)
Operation test/check
2
1
Used to check the operations of the auto document feed unit and the control circuits.
DSPF
Operation test/check
2
Used to check the operations of the sensors and detectors in the auto document feed unit and
the control circuits.
the control circuits.
DSPF
Operation test/check
3
Used to check the operations of the loads in the auto document feed unit and the control circuit.
DSPF
Operation test/check
6
Used to check the operation of the scanner fan motor.
Scanner (reading)
Operation test/check
3
2
Used to check the operations of the sensors and the detectors in the finisher and the control
circuits.
circuits.
Finisher
Operation test/check
3
Used to check the operations of the motors and the solenoids in the finisher and the control
circuits.
circuits.
Finisher
Operation test/check
10
Used to adjust the jogger position, the lead edge stopper position, the staple jogging count
number, and the paper folding count number.
number, and the paper folding count number.
Finisher
Finisher adjustment
30
Used to check the operations of the sensors and the detectors in the inserter and the related
circuits.
circuits.
Inserter
Operation test/check
31
Used to check the operations of the loads in the inserter and the control circuits.
Inserter
Operation test/check
40
Used to check the operations of the sensors and the detectors in the paper folding unit and the
related circuits.
related circuits.
Paper folding unit
Operation test/check
41
Used to check the operations of the motors and the solenoids in the paper folding unit and the
control circuits.
control circuits.
Paper folding unit
Operation test/check
42
Paper folding unit adjustment
Paper folding unit
Adjustment
50
Decurler sensor check
Decurler
Operation check
51
Decurler individual load check
Decurler unit
Operation check
4
2
Used to check the operations of the sensors and the detectors in the large capacity tray (LCC)
and the control circuits.
and the control circuits.
Large capacity tray
(LCC)
(LCC)
Operation test/check
3
Used to check the operations of the loads in the desk/large capacity tray (LCC) and the control
circuits.
circuits.
Desk/Large capacity
tray
tray
Operation test/check
5
Used to check the operations of the transport clutch (LTRC) in the LCC and the monitor.
Large capacity tray
(LCC)
(LCC)
Operation test/check
10
LCT warm air heater temperature setting
LCT
Setting
11
LCT fan Duty setting
LCT
Setting
14
LCT temperature and humidity sensor monitor display
LCT
Check
5
1
Used to check the operations of the display lamp and the LCD on the operation panel and the
control circuit.
control circuit.
Operation panel
Operation test/check
2
Used to check the operation of the heater lamp and the control circuit.
Fusing
Operation test/check
3
Used to check the operations of the copy lamp and the control circuit.
Scanner/DSPF
(reading)
(reading)
Operation test/check
4
Used to check the operations of the discharge lamp and the control circuit.
Process
Operation test/check
6
1
Paper transport,
paper exit
paper exit
Operation test/check
2
Used to check the operations of each fan motor and the control circuit.
Operation test/check
3
Used to check the operations of the primary transfer separation.
Process (transfer)
Operation test/check
4
Used to check the operation of the MC cleaner.
Process (charging)
Operation test/check
90
Used to reset the machine to the factory setting. (The scanner is set to the lock enable position)
Scanner
Setting
7
1
Used to set the conditions of aging operation.
Setting
6
Used to set the intermittent aging cycle.
Setting
8
Used to display the warm-up time.
Operation display
12
Used to set the document scan quantity. (For development and inspection)
Operation test, check
8
1
Used to check and adjust the developing voltage in each print mode and the control circuit.
Process
(Development)
(Development)
Operation test/check/
adjustment
adjustment
2
Used to check and adjust the operations of the main charger grid voltage in each print mode and
the control circuit.
the control circuit.
Process
Operation test/check/
adjustment
adjustment
6
Used to check and adjust the operation of the transfer plus bias current and the control circuit.
Process (transfer)
Operation test/check/
adjustment
adjustment
9
2
Used to check the operations of the sensors and detectors in the paper reverse section (duplex
section) and its control circuit.
section) and its control circuit.
Duplex
Operation test/check
3
Used to check the operations of the load in the paper reverse section (duplex section) and its
control circuit.
control circuit.
Duplex
Operation test/check
10
1
Used to check the operation of the toner motor and the control circuit.
Process
(Development)
(Development)
Operation test/check
2
Used to check the operation of the toner hopper empty sensor.
Process
(Development)
(Development)
Operation test/check
4
Use to check the toner cartridge motor rotation sensor.
13
-
Used to cancel the self diag U1 trouble.
Cancel (trouble, etc.)
14
-
Used to cancel the self diag H3/H4/H5 troubles.
Fusing
Cancel (trouble, etc.)
15
-
Use to cancel the trouble (F3-12,22/U6-09,29,39,63,69)
LCC
Cancel (trouble, etc.)
16
-
Used to cancel the self diag U2 trouble.
MFPcnt PWB/PCU
PWB/SCU PWB
PWB/SCU PWB
Cancel (trouble, etc.)
MX-M905 SIMULATION 6 – 3
21
1
Used to set the maintenance cycle.
Setting
22
1
Used to check the print count value of each section and each operation mode.
(Used to check the maintenance timing.)
(Used to check the maintenance timing.)
Adjustment, setting,
operation data output
and check
operation data output
and check
2
Used to check the total number of misfeed and trouble. (If the total number of JAM is
considerably great, it is judged that repair is required.)
considerably great, it is judged that repair is required.)
Adjustment/Setting/
Operation data check
Operation data check
3
Used to check the misfeed position and the number of misfeed. * This data can be used to
estimate the trouble position.
estimate the trouble position.
Adjustment/Setting/
Operation data check
Operation data check
4
Used to check the trouble (self diag) history.
Adjustment/Setting/
Operation data check
Operation data check
5
Used to check the ROM version of each unit (section).
Other
6
Used to output the list of various setting and adjustment data (simulation, FAX soft switch,
counter).
counter).
Adjustment/Setting/
Operation data check
Operation data check
8
Used to check the counter value of the finisher, DSPF, and the scan (reading).
Adjustment/Setting/
Operation data check
Operation data check
9
Used to check the use quantity (print quantity) of each paper feed section.
Paper feed, ADU,
LCC
LCC
Adjustment/Setting/
Operation data check
Operation data check
10
Used to check the system configuration (option, internal hardware).
Adjustment/Setting/
Operation data check
Operation data check
11
Used to check the use frequency (send/receive) of FAX. (Only when FAX is installed.)
FAX
Adjustment/Setting/
Operation data check
Operation data check
12
Used to check the DSPF misfeed position and the number of each misfeed.
(If the number of misfeed is considerably great, it is judged that repair is required.)
(If the number of misfeed is considerably great, it is judged that repair is required.)
DSPF Adjustment/Setting/
Operation data check
13
Used to check the operating time of the process section (OPC drum, DV unit, toner cartridge).
Adjustment/Setting/
Operation data check
Operation data check
14
Used to display the use status of the toner cartridge.
Process
Adjustment/Setting/
Operation data check
Operation data check
18
Used to display the user data delete history.
Adjustment/Setting/
Operation data check
Operation data check
19
Used to check the various scanner counters related to the network scanner.
Adjustment/Setting/
Operation data check
Operation data check
40
Used to display the error code list and the contents.
Error contents
display
display
41
Purpose JAM code contents display.
Used to display the
JAM code list and the
contents.
JAM code list and the
contents.
42
Used to check the JAM/trouble data
Adjustment/Setting/
Operation data check
Operation data check
43
JAM data details display
Adjustment/Setting/
Operation data check
Operation data check
90
Used to output the various setting data.
Adjustment/Setting/
Operation data check
Operation data check
23
2
Used to print the paper jam, misfeed, and the trouble history. (If the number of misfeed or the
troubles is considerably great, it is judged that repair is required.)
troubles is considerably great, it is judged that repair is required.)
Adjustment/Setting/
Operation data check
Operation data check
80
Used to check the operation of paper feed and paper transport in the paper feed section and the
paper transport section. Used to output the list of the operation status of the sensor and the
detectors in the paper feed section and the paper transport section.
paper transport section. Used to output the list of the operation status of the sensor and the
detectors in the paper feed section and the paper transport section.
Paper feed, Paper
transport
transport
Operation test/check
81
Used to export paper feed time list.
24
1
Used to clear the jam counter and the trouble counter. (After completion of maintenance, the
counters are cleared.)
counters are cleared.)
Data clear
2
Used to clear the counter value (print quantity) in each paper feed section.
Data clear
3
Used to clear the counter value of the finisher, DSPF, and the scan (reading).
Data clear
4
Used to clear the drum counter value of the maintenance counter, the transfer, and the fusing
web cleaning feed counter. (After completion of maintenance, the counters are cleared.)
web cleaning feed counter. (After completion of maintenance, the counters are cleared.)
Data clear
5
Used to clear the developer counter value.
(After replacement of developer, the counter is cleared.)
(After replacement of developer, the counter is cleared.)
Data clear
6
Used to clear the copy counter value.
Data clear
9
Used to clear the printer mode print counter and the self print mode print counter.
Data clear
10
Used to clear the FAX counter value. (Only when the FAX is installed.)
Data clear
12
Used to clear the document filing counter.
Data clear
15
Clearing counters related to the network scanner
Data clear
35
Used to clear the toner cartridge use status data.
25
1
Used to check the operation of the developing section.
Process
(developing section)
(developing section)
Operation test/check
2
Used to initialize the toner density when replacing developer. (Automatic adjustment)
Process
(Developing section)
(Developing section)
Setting
4
Used to display the operation data of the toner supply quantity. (Not used in the market.)
Process
Adjustment/Setting/
Operation data check
Operation data check
10
Developer/drum serial number setting.
26
2
Used to set the paper size of the tandem tray/large capacity paper feed tray (LCC). (When the
paper size is changed, this simulation must be used to change the paper size on the software.)
paper size is changed, this simulation must be used to change the paper size on the software.)
Paper feed
Setting
3
Used to set the auditor specification mode.Sim.26-3 is described in the service manual for the
convenience sake, but the coin vendors of the machines destined for overseas are not
guaranteed.
convenience sake, but the coin vendors of the machines destined for overseas are not
guaranteed.
Auditor
Setting
Main
Sub
Function (Purpose)
Section
Purpose