DOWNLOAD Sharp MX-M904 / MX-M1204 (serv.man9) Service Manual ↓ Size: 27.84 MB | Pages: 127 in PDF or view online for FREE

Model
MX-M904 MX-M1204 (serv.man9)
Pages
127
Size
27.84 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Installation Manual (Revised May 2017).
File
mx-m904-mx-m1204-sm9.pdf
Date

Sharp MX-M904 / MX-M1204 (serv.man9) Service Manual ▷ View online

MX-M1204  MX-M904/M1054/M1204 (MAIN UNIT)  2 – 17
7)
Select [FACTORY] target, and press [EXECUTE] key. 
When the gray balance is customized with the manual gray
balance adjustment (SIM 67-25) according to the user's
request and the gray balance is registered as the service tar-
get with SIM 67-27, if the gray balance is adjusted to that gray
balance, select the [SERVICE] target. 
The printer gray balance adjustment (step 1) is automatically
performed and the gray balance check patch image is printed
out. 
If there is any streak or unclear print on the printed check pat-
tern, check the print engine for any problems.
8)
The initial setting menu of the halftone image correction is dis-
played. 
Press [OK] key. 
The initial setting of the halftone image correction is per-
formed.
9)
Wait until [EXECUTE] key is displayed. 
When it is displayed, press it. 
The halftone image correction is performed.
10) When "COMPLETED THIS PROCEDURE" is displayed, the
adjustment operation is completed. 
Cancel SIM46-74.
NOTE: The adjustment result becomes valid only when the
both adjustments in the copy mode and in the printer
mode are completed. 
For example, if the copy gray balance adjustment
(automatic adjustment) is performed and the simula-
tion is canceled, the adjustment result is invalid.
11) Check the copy gray balance and density. 
(Refer to the item of the copy gray balance and density check.) 
When the gray balance and the density are unsatisfactory after
the automatic adjustment by selecting the factory target in pro-
cedure 4), execute the manual gray balance adjustment
(ADJ11C (2)). 
Also when the service target is selected in procedure 4) to exe-
cute the automatic adjustment and a satisfactory result is not
obtained, perform the manual gray balance adjustment (ADJ
11C (2)).
12) Check the printer gray balance and density. 
(Refer to the item of the printer gray balance and density
check.) 
If a satisfactory result on the gray balance and the density is
not obtained with the automatic adjustment, execute the man-
ual adjustment (SIM 67-25) (ADJ 11E (2)). 
Also when the service target is selected in procedure 7) to exe-
cute the automatic adjustment and a satisfactory result is not
obtained, perform the manual gray balance adjustment (ADJ
11E (2)). 
If the gray balance or density is not in the satisfactory level
even after execution of the automatic and manual adjustments,
there may be another cause. 
Troubleshoot the cause, repair or perform necessary works,
and repeat the adjustment from the beginning.
M. Function and operation check
Check that the following operations are normal.
N. Setup and adjustment data recording
Print the various setup data and the adjustment data (list) with
SIM22-6 and keep the data.
• In case of a memory problems, if the data is not kept, all the
adjustments must be made again.
• If the data is kept, the setup values and the adjustment values
can be entered without adjustments, shortening the servicing
time.
Q
O P
N
M
L
K
J
I
H
G
F
E
D
C
B
A
Bk
1) The max. density section is not blurred.
2) Patch C or D is very slightly copied.
3)
The patch density is identical between patches or not reversed.
The patch density is changed gradually.
High density
Low density
Check item list
Equipped condition
Key-in (operation panel)
Display (operation panel)
Paper feed 
operation
Hand feed
Paper tray
Paper size detection
Originals size 
detection
Original table 
mode
DSPF mode
DSPF 
operation/
duplex 
operation
S-S mode
D-S mode
S-D mode
D-D mode
Bookbinding operation
When the finisher is installed
Stapling operation
When the finisher is installed
Grouping operation
When the finisher is installed
Sorting operation
When the finisher is installed
MX-M1204  MX-M904/M1054/M1204 (MAIN UNIT)  2 – 18
O. Necessary procedures before moving the 
machine
1)
If the following options are installed, remove all of them from
the machine.
• Large capacity tray
• Inserter
• Finisher
• High capacity stacker
• Curl correction unit
• Relay unit
• Paper feed system option
2)
Remove the following consumable parts from the machine.
• Paper
• Toner cartridge
• Development cartridge
3)
Lock the following sections.
• Scanner (Optical section)
• Paper cassette lift plate
4)
Attach the protection material to the position shown below. 
• Use the "packing material for fixing the separation pawls"
which was removed when unpacking.
NOTE: Since the hard disk drive is built in the machine, refrain
from vibrations or shocks to the machine when in transit.
MX-M1204  Dehumidifying heater kit  3 – 1
MX-M1204
Service Manual
 
[3] Dehumidifying heater kit
1.  Parts list
Kit name
Kit part code
Parts name
Part code
Q'ty
Remarks
Heater kit HER200
DKIT-0406FCZZ
WH PWB
CPWBF1569FCE2
1
Supporter SPLSN-6
LSUPP0118FCPZ
5
WH harness
DHAI-4075HCPZ
1
Heater SW
QSW-C9294QCZZ
1
Heater SW label Pa EX
TLABZ5256FCZZ
1
SCN dehumidifier heater 230V
RHETP0148FCPZ
1
For SCN heater mounting
Snap band
LBNDJ0071FCZZ
2
For SCN heater mounting
Screw (M3 x 4cap, black)
LX-BZ0324FCPZ
2
For SCN heater mounting
Edge saddle, black
LBSHC0161FCZZ
1
For SCN heater mounting
Main unit cassette heater (240)V
RHETP0150FCPZ
2
For main unit heater mounting
Heater mounting plate
LPLTM6089FCZZ
2
For main unit heater mounting
T heater cover
PCOVP1654FCZ2
2
For main unit heater mounting
Heater cover sheet
PSHEZ5012FCZZ
2
For main unit heater mounting
Heater harness sheet
PSHEZ5135FCZZ
2
For main unit heater mounting
Screw (M3 x 6S)
XHBS730P06000
7
For main unit heater mounting
(For dehumidifier heater unit: x6, For 
cassette 4 heater: x1)
High temperature caution label
TLABZ5217FCZZ
1
For main unit heater mounting
High temperature caution mark label
TLABZ4900FCZZ
1
For main unit heater mounting
Screw (M4 x 8S)
XHBS740P08000
1
For cassette 3 heater mounting
Kit name
Kit part code
Parts name
Part code
Q'ty
LCC (A4) heater kit
DKIT-0437FC11 (200V series)
DKIT-0437FC12 (200V series)
Heater harness (Ex200V North America)
DHAI-5199FCPZ
1
Heater harness (Ex200V Europe)
DHAI-5200FCPZ
Snap band
LBNDJ0043FCP1
1
AC cord fixer
LFIX-0016FCZZ
1
Connector cover A
PCOVP2149FCZZ
1
Connector cover B
PCOVP2150FCZZ
1
Heater (200V series)
RHETP0121FCZZ
1
Screw (M4 x 8K)
XBPS740P08K00
1
Screw (M3 x 4)
XHBS730P04000
1
Screw for EL connector
LX-BZ1119FCZZ
1
Screw (M4 x 28K)
XBPS740P28KS0
2
Screw (M3 x 20)
XBBS730P20000
3
Screw (M4 x 8)
XHBS740P08000
1
Nut (M3 = 2.4)
XNES730-24000
3
LCC (A3) heater kit
DKIT-0439FCZZ (200V series)
DKIT-0440FCZZ (200V series)
Heater harness A3 (Ex200V North America)
DHAI-5203FCPZ
1
Heater harness A3 (Ex200V Europe)
DHAI-5204FCPZ
Snap band
LBNDJ0043FCP1
1
AC cord fixer
LFIX-0016FCZZ
1
Connector cover A
PCOVP2149FCZZ
1
Connector cover B
PCOVP2150FCZZ
1
Heater (200V series)
RHETP0121FCZZ
1
Screw (M4 x 8K)
XBPS740P08K00
1
Screw (M3 x 4)
XHBS730P04000
1
Screw for EL connector
LX-BZ1119FCZZ
1
Screw (M4 x 28K)
XBPS740P28KS0
2
Screw (M3 x 20)
XBBS730P20000
3
Screw (M4 x 8)
XHBS740P08000
1
Nut (M3 = 2.4)
XNES730-24000
3
Heater cover
PCOVP1942FCZZ
1
Heater sheet
PSHEZ5482FCZZ
1
Screw (M4 x 8 Round-tipped S-tight)
LX-BZ0941FCPZ
2
7
: ‘16/Sept.
7
7
MX-M1204  Dehumidifying heater kit  3 – 2
LCT heater kit
DKIT-0442FCZZ (120V series)
DKIT-0442FC11 (200V series)
LCT heater (120V series)
RHETP0145FCZZ
2
LCT heater (200V series)
RHETP0121FCZZ
LCT heater mount plate
LPLTM8436FCZZ
2
Mini clamp
LHLDW1009ACZZ
4
Edge wire saddle
LHLDW1503FCZZ
6
Screw (M3x4 S-tight)
XHBS730P04000
16
Desk heater (120V series)
RHETP0144FCZZ
3
Desk heater (200V series)
RHETP0139FCZZ
Desk heater mount plate
LPLTM6021FCZZ
3
Heater heat sink
PRDAR0087FCZZ
3
Mini clamp
0EUHLD0214C//
9
Screw (M3x6 S-tight)
XHBS730P06000
6
Screw (M4x8 S-tight)
XHBS740P08000
2
Step screw
LX-BZ0714FCPZ
2
High temperature warning label
TLABZ4900FCZZ
2
Dehumidifier heater switch
QSW-C9294QCZZ
1
LCT WH SW harness
DHAI-5131FCPZ
1
LCT heater harness 1 (120V series)
DHAI-5143FCPZ 
1
LCT heater harness 1 (200V series)
DHAI-5251FCPZ 
LCT heater harness 2 (120V series)
DHAI-5144FCPZ 
1
LCT heater harness 2 (200V series)
DHAI-5252FCPZ 
Heater SW label Pa EX
TLABZ5256FCZZ
1
Kit name
Kit part code
Parts name
Part code
Q'ty
Page of 127
Display