Sharp MX-M266N / MX-M316N / MX-M356N Handy Guide ▷ View online
SHARP
FIRMWARE UPGRADE
21
6. Firmware update progress (and remaining time) should now be displayed:‐
7. Once the firmware update has completed successfully, select OK (MFP should reboot).
Firmware update is complete.
FIRMWARE UPGRADE
SHARP
22
NETWORK CONNECTION (MFP WEB PAGE)
1. Open a web browser and enter the following URL :‐
http://ipaddress/service_login.html or http://ipaddress/service_account.html
Example: http://192.168.0.136/service_login.html
Note: If User Authentication (username & password) is enabled, open the device webpage and
“login” using the service username and password (as below):‐
2. Select/Enter the “Service” Username and Password to access the Service Webpage and click Login:‐
Default
Username: service
Password:
service
3. When the service webpage opens, click Update of Firmware:‐
SHARP
FIRMWARE UPGRADE
23
4. Click Browse to navigate to the location of the updated firmware file and select Open:‐
5. Press Execute to start the firmware update.
Note: Once the machine has entered “service download mode”, the update will commence and the
progress will be displayed.
6. When the firmware upgrade is complete, click Reboot to execute a remote restart of the machine.
Firmware Upgrade is complete
FIRMWARE RECOVERY
SHARP
24
In the event of a power failure during a firmware update, the device may fail to “reboot” because of
corrupted firmware. Using the CN Update procedure described below, this function is used to
update/recover the firmware by transferring data to the MFP PWB, SCU PWB, PCU PWB, FAX PWB, and
various options by means of a USB memory.
MENU KEY REFERENCE:
The following five key areas are used for operations during CN update mode:‐
corrupted firmware. Using the CN Update procedure described below, this function is used to
update/recover the firmware by transferring data to the MFP PWB, SCU PWB, PCU PWB, FAX PWB, and
various options by means of a USB memory.
MENU KEY REFERENCE:
The following five key areas are used for operations during CN update mode:‐
CN UPDATE ‐ Firmware Recovery Procedure:‐
1. Power off the MFP, remove the Rear Cabinet and MFP PWB cover:‐
2. Set the MFP PWB UPDATE DIP‐SW to ON:‐
3. Install the USB Memory containing the MX‐M266/316N firmware into the USB slot:‐
4. Power ON the MFP device ‐ the boot menu should appear after approx 10 seconds, followed by
Version Check information:‐.
Version Check
Conf: 00050000
Conf: 00050000
Update Prog Init
Please wait
Please wait