DOWNLOAD Sharp MX-M160 / MX-M160D / MX-M160DK (serv.man7) Service Manual ↓ Size: 4.82 MB | Pages: 100 in PDF or view online for FREE

Model
MX-M160 MX-M160D MX-M160DK (serv.man7)
Pages
100
Size
4.82 MB
Type
PDF
Document
User Manual / Operation Manual
Brand
Device
Copying Equipment / Operation Manual.
File
mx-m160-mx-m160d-mx-m160dk-sm7.pdf
Date

Sharp MX-M160 / MX-M160D / MX-M160DK (serv.man7) User Manual / Operation Manual ▷ View online

83
SYSTEM SETTINGS GUIDE
7
RETURN FROM COPY MODE TIMING
When there are print jobs or fax print jobs waiting to be 
printed after copy job is finished, this program is used 
to set a brief wait time until printing of those jobs 
begins. Setting a brief wait time allows another copy 
job to be performed following the previous copy job.
Time selections are "0 sec.", "10 sec.", "30 sec.", and 
"60 sec.".
The factory default setting is 30 seconds.
Select "RETURN FROM COPY MODE TIMING" and 
press the [OK] key. The following screen will appear.
1
Select the desired time with the [
] or [
key.
2
Press the [OK] key.
OPERATION SETTING
These programs are used to configure various settings 
related to the operation panel. To access one of these 
programs, select "OPERATION SETTING" in the 
mode selection screen, select the desired program in 
the operation setting screen, and press the [OK] key.
AUTO CLEAR
This function returns the copy settings to the default 
settings if the operation panel is not used for the 
duration of time set with this program following the end 
of a copy job. Time selections are "0 sec.", "10 sec.", 
"20 sec.", "60 sec.", "90 sec." and "120 sec.".
The factory default setting is 60 seconds.
Select "AUTO CLEAR" and press the [OK] key. The 
following screen will appear.
1
Select the desired time with the [
] or [
key.
If you do not want auto clear to operate, select "0".
2
Press the [OK] key.
DISABLE DISPLAY TIMEOUT
This program is used to select whether or not the 
display will automatically return to the base screen if 
no keys are pressed on the operation panel for one 
minute in scan or fax mode.
The factory default setting is automatic return to the 
base screen.
To disable automatic return to the base screen, select 
"DISABLE DISPLAY TIMEOUT", and press the [OK] 
key so that a checkmark appears in the checkbox.
To re-enable automatic return to the base screen, 
select "DISABLE DISPLAY TIMEOUT" once again 
and press the [OK] key to clear the checkmark 
from the checkbox.
LANGUAGE SETTING
This program is used to select the display language.
Select "LANGUAGE SETTING", press the [OK] key, 
and follow the steps below.
1
Select the display language with the [
] or 
[
] key.
2
Press the [OK] key.
MESSAGE TIME
This program is used to set the length of time that 
messages appear in the display (this applies to 
messages that appear for a certain length of time and 
then automatically disappear.) Select from "SHORT (3 
sec.)", "NORMAL (6 sec.)", or "LONG (9 sec.)".
The factory default setting is "NORMAL (6 sec.)".
System requirements for USB 2.0 
(Hi-Speed mode)
The USB port on the machine supports USB 2.0 
Hi-Speed mode.
The following system is required to use USB 2.0 
(Hi-Speed mode):
The computer is running Windows Vista/XP/2000 and 
the Microsoft USB 2.0 driver is pre-installed, or the USB 
2.0 driver for Windows Vista/XP/2000 that Microsoft 
provides through Windows Update is installed.
* Even when the Microsoft USB 2.0 driver is installed, 
some USB 2.0 expansion cards are not capable of 
attaining the speed stipulated by the Hi-Speed 
standard. This problem can often be fixed by installing 
a more recent driver for the card. To obtain the most 
recent driver for your card, contact the card's 
manufacturer.
 RETURN FROM COPY
      
 30
  sec.
     (0~60)
 AUTO CLEAR
      
 60
  sec.
    (0~120)
Pegasus-E_Copy_Ex.book  83 ページ  2009年7月22日 水曜日 午後2時4分
84
SYSTEM SETTINGS GUIDE
Select "MESSAGE TIME" and press the [OK] key. The 
following screen will appear.
1
Select the desired display time with the 
[
] or [
] key.
2
Press the [OK] key.
KEY TOUCH SOUND
This program is used to set the volume of the key 
touch sound that is heard each time a key is pressed.
The initial factory setting is "SHORT".
Select "KEY TOUCH SOUND" and press the [OK] key. 
The following screen will appear.
1
Select the desired volume with the [
] or 
[
] key.
To turn the key touch sound off, select "OFF".
2
Press the [OK] key.
KEYS TOUCH SOUND AT INITIAL 
POINT
This program is used to select whether or not a beep 
will sound at preset base settings as you press a key 
to select a setting.
The factory default setting is no beep.
If you would like a beep to sound, select "KEYS 
TOUCH SOUND AT INITIAL POINT" and press the 
[OK] key so that a checkmark appears in the 
checkbox.
If you would not like a beep to sound, select 
"KEYS TOUCH SOUND AT INITIAL POINT" once 
again and press the [OK] key so that the 
checkmark is cleared from the checkbox.
KEY PRESS TIME
This program is used to set the duration of time that a 
key must be pressed to take effect.
A longer setting can be selected to prevent keys 
pressed accidentally from taking effect. Keep in mind, 
however, that when a longer setting is selected more 
care is required when pressing keys to ensure that the 
key input is registered.
The initial factory setting is "MINIMUM".
Select "KEY PRESS TIME" and press the [OK] key. 
The following screen appears.
1
Select the desired time with the [
] or [
key.
2
Press the [OK] key.
DISABLE AUTO KEY REPEAT
This program is used to stop a setting from changing 
continuously when the [
] or [
] key is held down, 
such as when setting the zoom ratio or the original size 
(auto key repeat will not operate). When this program 
is enabled, a key must be pressed repeatedly instead 
of holding it down.
Auto key repeat is initially set to operate (factory 
default setting).
To disable auto key repeat, select "DISABLE AUTO 
KEY REPEAT" and press the [OK] key so that a 
checkmark appears in the checkbox.
To re-enable auto key repeat, select "DISABLE 
AUTO KEY REPEAT" once again and press the 
[OK] key so that the checkmark is cleared from the 
checkbox.
DISABLE PAPER SIZE SET
This program is used to disable "PAPER SIZE SET" in 
the special functions menu. When disabled, "PAPER 
SIZE SET" cannot be used when the [SPECIAL 
FUNCTIONS] key is pressed, which prevents users 
other than the administrator from easily changing the 
paper size setting.
"DISABLE PAPER SIZE SET" is initially disabled 
(factory default setting).
 MESSAGE TIME
  SHORT  (3 sec.)
  
NORMAL (6 sec.)
  LONG   (9 sec.)
 KEY TOUCH SOUND
  OFF
  
SHORT
  LONG
 KEY PRESS TIME
  
MINIMUM
  0.5 sec.
  1.0 sec.
  1.5 sec.
Pegasus-E_Copy_Ex.book  84 ページ  2009年7月22日 水曜日 午後2時4分
85
SYSTEM SETTINGS GUIDE
7
To enable the setting, select "DISABLE PAPER 
SIZE SET" and press the [OK] key so that a 
checkmark appears in the checkbox.
To disable the setting, select "DISABLE PAPER 
SIZE SET" once again and press the [OK] key so 
that the checkmark is cleared from the checkbox.
ENERGY SAVE
These programs are used to configure energy saving 
settings. To access one of these programs, select 
"ENERGY SAVE" in the mode selection screen, and 
select the desired program in the energy save screen, 
and then press the [OK] key.
AUTO POWER SHUT-OFF
This program is used to enable auto power shut-off 
mode, which automatically turns off the power to the 
fusing unit if the operation panel is not used for a 
certain duration of time.
Enabling auto power shut-off mode helps conserve 
energy, preserve natural resources, and reduce 
environmental pollution.
The function is initially enabled.
To enable auto power shut-off mode, select "AUTO 
POWER SHUT-OFF", and press the [OK] key so 
that a checkmark appears in the checkbox.
To disable auto power shut-off mode, select 
"AUTO POWER SHUT-OFF" once again and press 
the [OK] key so that the checkmark is cleared from 
the checkbox.
AUTO POWER SHUT-OFF TIMER
This program is used to set the duration of time until 
auto power shut-off mode activates when the 
operation panel is not used. Using this function helps 
conserve energy, preserve natural resources, and 
reduce environmental pollution.
"1 min.", "5 min.", "30 min.", "60 min.", "120 min." or 
"240 min." can be selected for the duration of time. 
Select a setting that suits your work conditions.
Select "AUTO POWER SHUT-OFF TIMER" and press 
the [OK] key. The following screen will appear.
1
Select the desired time with the [
] or [
key.
2
Press the [OK] key.
PREHEAT MODE
This program is used to set the duration of time until 
preheat mode, which automatically lowers the fusing 
unit temperature, activates when the operation panel is 
not used. Using this function helps conserve energy, 
preserve natural resources, and reduce environmental 
pollution. "1 min.", "5 min.", "30 min.", "60 min.", "120 
min.", or "240 min." can be selected for the duration of 
time. Select a setting that suits your work conditions.
Select "PREHEAT MODE" and press the [OK] key. 
The following screen will appear.
1
Select the desired time with the [
] or [
key.
2
Press the [OK] key.
TONER SAVE MODE
The toner save mode will reduce toner consumption by 
approximately 10% in the automatic and text, 
exposure modes. Copies will be lighter but still 
adequate for general use. Selection of this mode has 
no effect on the photo mode.
The function is initially disabled (factory default 
setting).
To turn on the toner save mode, highlight "TONER 
SAVE MODE" and press the [OK] key to display a 
check mark in the check box.
To turn off the toner save mode, select this 
program and press the [OK] key again to clear the 
check mark in the check box.
Rather than disabling the auto power 
shut-off feature, it is recommended that you 
first try lengthening the time set in "AUTO 
POWER SHUT-OFF TIMER" (see below). In 
most cases a suitable timer setting will allow 
work to proceed with minimal delay and still 
enable you to enjoy the benefits of power 
conservation.
Note
 AUTO POWER OFF
        
 
  min.
    (1~240)
 PREHEAT MODE
        
 
  min.
    (1~240)
Pegasus-E_Copy_Ex.book  85 ページ  2009年7月22日 水曜日 午後2時4分
86
SYSTEM SETTINGS GUIDE
COPY SETTINGS
These programs are used to enable various copy 
functions. To access one of these programs, select 
"COPIER" in the mode selection screen, select the 
desired program in the copy settings screen, and 
press the [OK] key.
EXPOSURE ADJUST
This program is used to adjust the exposure level 
when "AUTO" is used for the exposure mode. The 
auto exposure level can be set separately for the 
document glass and the SPF.
One of five levels can be selected, with the left end of 
the scale the lightest level and the right end of the 
scale the darkest level.
The factory default setting is the middle level.
Select "EXPOSURE ADJUST" and press the [OK] key. 
The following screen will appear.
1
Select "PLATEN" or "SPF/RSPF" with the 
[
] or [
] key.
2
Press the [
] or [
] key to adjust the 
exposure.
3
Repeat steps 1 and 2 to adjust the other 
exposure.
4
Press the [OK] key.
MARGIN DEFAULT
(When the dual function board is installed)
This is used to set the default margin width.
The factory default setting is "10 mm (1/2 inch)".
Select "MARGIN DEFAULT" and press the [OK] key. 
The following screen will appear.
1
Adjust the default margin width with the 
[
] or [
] key.
The width can be set from 0 to 20 mm in increments of 5 
mm (0" to 1" in increments of 1/4").
2
Press the [OK] key.
ERASE ADJUST
(When the dual function board is installed)
This is used to set the default erasure width.
The factory default setting is "10 mm (1/2 inch)".
Select "ERASE ADJUST" and press the [OK] key. The 
following screen will appear.
1
Adjust the edge erase and centre erase 
width with the [
] or [
] key.
The edge erase width and the centre erase width share 
the same default value, which can be set from 0 to 20 
mm in increments of 5 mm (0" to 1" in increments of 
1/4").
2
Press the [OK] key.
CARD SHOT DEFAULT
(When the dual function board is installed)
This program is used to set the default dimensions that 
appear when the card shot size entry screen is displayed.
The factory default settings are 86 mm (3-3/8") for the 
width (X) and 54 mm (2-1/8") for the length (Y).
Select "CARD SHOT DEFAULT" and press the [OK] 
key. The following screen will appear.
1
Select X or Y with the [
] or [
] key and 
adjust the corresponding default value 
with the [
] or [
] key.
2
Press the [OK] key.
DEFAULT TRAY SET
This program is used to set which tray is selected by 
default.
Trays that appear for selection will vary depending on 
the optional trays that have been installed.
The factory default setting is "TRAY 1".
 EXPOSURE ADJUST
  
PLATEN
  SPF/RSPF
                   
 MARGIN DEFAULT
      
   
  mm
     (0~20)
 ERASE ADJUST
      
   
  mm
     (0~20)
 CARD SHOT DEFAULT
  SIZE(mm)
 X:    
 Y:    
Pegasus-E_Copy_Ex.book  86 ページ  2009年7月22日 水曜日 午後2時4分
Page of 100
Display