Sharp MX-M160 / MX-M160D / MX-M160DK (serv.man7) User Manual / Operation Manual ▷ View online
83
SYSTEM SETTINGS GUIDE
7
RETURN FROM COPY MODE TIMING
When there are print jobs or fax print jobs waiting to be
printed after copy job is finished, this program is used
to set a brief wait time until printing of those jobs
begins. Setting a brief wait time allows another copy
job to be performed following the previous copy job.
Time selections are "0 sec.", "10 sec.", "30 sec.", and
"60 sec.".
The factory default setting is 30 seconds.
printed after copy job is finished, this program is used
to set a brief wait time until printing of those jobs
begins. Setting a brief wait time allows another copy
job to be performed following the previous copy job.
Time selections are "0 sec.", "10 sec.", "30 sec.", and
"60 sec.".
The factory default setting is 30 seconds.
Select "RETURN FROM COPY MODE TIMING" and
press the [OK] key. The following screen will appear.
press the [OK] key. The following screen will appear.
1
Select the desired time with the [
] or [
]
key.
2
Press the [OK] key.
OPERATION SETTING
These programs are used to configure various settings
related to the operation panel. To access one of these
programs, select "OPERATION SETTING" in the
mode selection screen, select the desired program in
the operation setting screen, and press the [OK] key.
related to the operation panel. To access one of these
programs, select "OPERATION SETTING" in the
mode selection screen, select the desired program in
the operation setting screen, and press the [OK] key.
AUTO CLEAR
This function returns the copy settings to the default
settings if the operation panel is not used for the
duration of time set with this program following the end
of a copy job. Time selections are "0 sec.", "10 sec.",
"20 sec.", "60 sec.", "90 sec." and "120 sec.".
The factory default setting is 60 seconds.
settings if the operation panel is not used for the
duration of time set with this program following the end
of a copy job. Time selections are "0 sec.", "10 sec.",
"20 sec.", "60 sec.", "90 sec." and "120 sec.".
The factory default setting is 60 seconds.
Select "AUTO CLEAR" and press the [OK] key. The
following screen will appear.
following screen will appear.
1
Select the desired time with the [
] or [
]
key.
If you do not want auto clear to operate, select "0".
2
Press the [OK] key.
DISABLE DISPLAY TIMEOUT
This program is used to select whether or not the
display will automatically return to the base screen if
no keys are pressed on the operation panel for one
minute in scan or fax mode.
The factory default setting is automatic return to the
base screen.
display will automatically return to the base screen if
no keys are pressed on the operation panel for one
minute in scan or fax mode.
The factory default setting is automatic return to the
base screen.
To disable automatic return to the base screen, select
"DISABLE DISPLAY TIMEOUT", and press the [OK]
key so that a checkmark appears in the checkbox.
"DISABLE DISPLAY TIMEOUT", and press the [OK]
key so that a checkmark appears in the checkbox.
To re-enable automatic return to the base screen,
select "DISABLE DISPLAY TIMEOUT" once again
and press the [OK] key to clear the checkmark
from the checkbox.
select "DISABLE DISPLAY TIMEOUT" once again
and press the [OK] key to clear the checkmark
from the checkbox.
LANGUAGE SETTING
This program is used to select the display language.
Select "LANGUAGE SETTING", press the [OK] key,
and follow the steps below.
Select "LANGUAGE SETTING", press the [OK] key,
and follow the steps below.
1
Select the display language with the [
] or
[
] key.
2
Press the [OK] key.
MESSAGE TIME
This program is used to set the length of time that
messages appear in the display (this applies to
messages that appear for a certain length of time and
then automatically disappear.) Select from "SHORT (3
sec.)", "NORMAL (6 sec.)", or "LONG (9 sec.)".
The factory default setting is "NORMAL (6 sec.)".
messages appear in the display (this applies to
messages that appear for a certain length of time and
then automatically disappear.) Select from "SHORT (3
sec.)", "NORMAL (6 sec.)", or "LONG (9 sec.)".
The factory default setting is "NORMAL (6 sec.)".
System requirements for USB 2.0
(Hi-Speed mode)
(Hi-Speed mode)
The USB port on the machine supports USB 2.0
Hi-Speed mode.
The following system is required to use USB 2.0
(Hi-Speed mode):
The computer is running Windows Vista/XP/2000 and
the Microsoft USB 2.0 driver is pre-installed, or the USB
2.0 driver for Windows Vista/XP/2000 that Microsoft
provides through Windows Update is installed.
Hi-Speed mode.
The following system is required to use USB 2.0
(Hi-Speed mode):
The computer is running Windows Vista/XP/2000 and
the Microsoft USB 2.0 driver is pre-installed, or the USB
2.0 driver for Windows Vista/XP/2000 that Microsoft
provides through Windows Update is installed.
* Even when the Microsoft USB 2.0 driver is installed,
some USB 2.0 expansion cards are not capable of
attaining the speed stipulated by the Hi-Speed
standard. This problem can often be fixed by installing
a more recent driver for the card. To obtain the most
recent driver for your card, contact the card's
manufacturer.
attaining the speed stipulated by the Hi-Speed
standard. This problem can often be fixed by installing
a more recent driver for the card. To obtain the most
recent driver for your card, contact the card's
manufacturer.
RETURN FROM COPY
30
sec.
(0~60)
AUTO CLEAR
60
sec.
(0~120)
Pegasus-E_Copy_Ex.book 83 ページ 2009年7月22日 水曜日 午後2時4分
84
SYSTEM SETTINGS GUIDE
Select "MESSAGE TIME" and press the [OK] key. The
following screen will appear.
following screen will appear.
1
Select the desired display time with the
[
[
] or [
] key.
2
Press the [OK] key.
KEY TOUCH SOUND
This program is used to set the volume of the key
touch sound that is heard each time a key is pressed.
The initial factory setting is "SHORT".
touch sound that is heard each time a key is pressed.
The initial factory setting is "SHORT".
Select "KEY TOUCH SOUND" and press the [OK] key.
The following screen will appear.
The following screen will appear.
1
Select the desired volume with the [
] or
[
] key.
To turn the key touch sound off, select "OFF".
2
Press the [OK] key.
KEYS TOUCH SOUND AT INITIAL
POINT
POINT
This program is used to select whether or not a beep
will sound at preset base settings as you press a key
to select a setting.
The factory default setting is no beep.
will sound at preset base settings as you press a key
to select a setting.
The factory default setting is no beep.
If you would like a beep to sound, select "KEYS
TOUCH SOUND AT INITIAL POINT" and press the
[OK] key so that a checkmark appears in the
checkbox.
TOUCH SOUND AT INITIAL POINT" and press the
[OK] key so that a checkmark appears in the
checkbox.
If you would not like a beep to sound, select
"KEYS TOUCH SOUND AT INITIAL POINT" once
again and press the [OK] key so that the
checkmark is cleared from the checkbox.
"KEYS TOUCH SOUND AT INITIAL POINT" once
again and press the [OK] key so that the
checkmark is cleared from the checkbox.
KEY PRESS TIME
This program is used to set the duration of time that a
key must be pressed to take effect.
A longer setting can be selected to prevent keys
pressed accidentally from taking effect. Keep in mind,
however, that when a longer setting is selected more
care is required when pressing keys to ensure that the
key input is registered.
The initial factory setting is "MINIMUM".
key must be pressed to take effect.
A longer setting can be selected to prevent keys
pressed accidentally from taking effect. Keep in mind,
however, that when a longer setting is selected more
care is required when pressing keys to ensure that the
key input is registered.
The initial factory setting is "MINIMUM".
Select "KEY PRESS TIME" and press the [OK] key.
The following screen appears.
The following screen appears.
1
Select the desired time with the [
] or [
]
key.
2
Press the [OK] key.
DISABLE AUTO KEY REPEAT
This program is used to stop a setting from changing
continuously when the [
continuously when the [
] or [
] key is held down,
such as when setting the zoom ratio or the original size
(auto key repeat will not operate). When this program
is enabled, a key must be pressed repeatedly instead
of holding it down.
Auto key repeat is initially set to operate (factory
default setting).
(auto key repeat will not operate). When this program
is enabled, a key must be pressed repeatedly instead
of holding it down.
Auto key repeat is initially set to operate (factory
default setting).
To disable auto key repeat, select "DISABLE AUTO
KEY REPEAT" and press the [OK] key so that a
checkmark appears in the checkbox.
KEY REPEAT" and press the [OK] key so that a
checkmark appears in the checkbox.
To re-enable auto key repeat, select "DISABLE
AUTO KEY REPEAT" once again and press the
[OK] key so that the checkmark is cleared from the
checkbox.
AUTO KEY REPEAT" once again and press the
[OK] key so that the checkmark is cleared from the
checkbox.
DISABLE PAPER SIZE SET
This program is used to disable "PAPER SIZE SET" in
the special functions menu. When disabled, "PAPER
SIZE SET" cannot be used when the [SPECIAL
FUNCTIONS] key is pressed, which prevents users
other than the administrator from easily changing the
paper size setting.
"DISABLE PAPER SIZE SET" is initially disabled
(factory default setting).
the special functions menu. When disabled, "PAPER
SIZE SET" cannot be used when the [SPECIAL
FUNCTIONS] key is pressed, which prevents users
other than the administrator from easily changing the
paper size setting.
"DISABLE PAPER SIZE SET" is initially disabled
(factory default setting).
MESSAGE TIME
SHORT (3 sec.)
SHORT (3 sec.)
NORMAL (6 sec.)
LONG (9 sec.)
KEY TOUCH SOUND
OFF
OFF
SHORT
LONG
KEY PRESS TIME
MINIMUM
0.5 sec.
1.0 sec.
1.5 sec.
1.0 sec.
1.5 sec.
Pegasus-E_Copy_Ex.book 84 ページ 2009年7月22日 水曜日 午後2時4分
85
SYSTEM SETTINGS GUIDE
7
To enable the setting, select "DISABLE PAPER
SIZE SET" and press the [OK] key so that a
checkmark appears in the checkbox.
SIZE SET" and press the [OK] key so that a
checkmark appears in the checkbox.
To disable the setting, select "DISABLE PAPER
SIZE SET" once again and press the [OK] key so
that the checkmark is cleared from the checkbox.
SIZE SET" once again and press the [OK] key so
that the checkmark is cleared from the checkbox.
ENERGY SAVE
These programs are used to configure energy saving
settings. To access one of these programs, select
"ENERGY SAVE" in the mode selection screen, and
select the desired program in the energy save screen,
and then press the [OK] key.
settings. To access one of these programs, select
"ENERGY SAVE" in the mode selection screen, and
select the desired program in the energy save screen,
and then press the [OK] key.
AUTO POWER SHUT-OFF
This program is used to enable auto power shut-off
mode, which automatically turns off the power to the
fusing unit if the operation panel is not used for a
certain duration of time.
Enabling auto power shut-off mode helps conserve
energy, preserve natural resources, and reduce
environmental pollution.
The function is initially enabled.
mode, which automatically turns off the power to the
fusing unit if the operation panel is not used for a
certain duration of time.
Enabling auto power shut-off mode helps conserve
energy, preserve natural resources, and reduce
environmental pollution.
The function is initially enabled.
To enable auto power shut-off mode, select "AUTO
POWER SHUT-OFF", and press the [OK] key so
that a checkmark appears in the checkbox.
POWER SHUT-OFF", and press the [OK] key so
that a checkmark appears in the checkbox.
To disable auto power shut-off mode, select
"AUTO POWER SHUT-OFF" once again and press
the [OK] key so that the checkmark is cleared from
the checkbox.
"AUTO POWER SHUT-OFF" once again and press
the [OK] key so that the checkmark is cleared from
the checkbox.
AUTO POWER SHUT-OFF TIMER
This program is used to set the duration of time until
auto power shut-off mode activates when the
operation panel is not used. Using this function helps
conserve energy, preserve natural resources, and
reduce environmental pollution.
"1 min.", "5 min.", "30 min.", "60 min.", "120 min." or
"240 min." can be selected for the duration of time.
Select a setting that suits your work conditions.
auto power shut-off mode activates when the
operation panel is not used. Using this function helps
conserve energy, preserve natural resources, and
reduce environmental pollution.
"1 min.", "5 min.", "30 min.", "60 min.", "120 min." or
"240 min." can be selected for the duration of time.
Select a setting that suits your work conditions.
Select "AUTO POWER SHUT-OFF TIMER" and press
the [OK] key. The following screen will appear.
the [OK] key. The following screen will appear.
1
Select the desired time with the [
] or [
]
key.
2
Press the [OK] key.
PREHEAT MODE
This program is used to set the duration of time until
preheat mode, which automatically lowers the fusing
unit temperature, activates when the operation panel is
not used. Using this function helps conserve energy,
preserve natural resources, and reduce environmental
pollution. "1 min.", "5 min.", "30 min.", "60 min.", "120
min.", or "240 min." can be selected for the duration of
time. Select a setting that suits your work conditions.
preheat mode, which automatically lowers the fusing
unit temperature, activates when the operation panel is
not used. Using this function helps conserve energy,
preserve natural resources, and reduce environmental
pollution. "1 min.", "5 min.", "30 min.", "60 min.", "120
min.", or "240 min." can be selected for the duration of
time. Select a setting that suits your work conditions.
Select "PREHEAT MODE" and press the [OK] key.
The following screen will appear.
The following screen will appear.
1
Select the desired time with the [
] or [
]
key.
2
Press the [OK] key.
TONER SAVE MODE
The toner save mode will reduce toner consumption by
approximately 10% in the automatic and text,
exposure modes. Copies will be lighter but still
adequate for general use. Selection of this mode has
no effect on the photo mode.
The function is initially disabled (factory default
setting).
approximately 10% in the automatic and text,
exposure modes. Copies will be lighter but still
adequate for general use. Selection of this mode has
no effect on the photo mode.
The function is initially disabled (factory default
setting).
To turn on the toner save mode, highlight "TONER
SAVE MODE" and press the [OK] key to display a
check mark in the check box.
SAVE MODE" and press the [OK] key to display a
check mark in the check box.
To turn off the toner save mode, select this
program and press the [OK] key again to clear the
check mark in the check box.
program and press the [OK] key again to clear the
check mark in the check box.
Rather than disabling the auto power
shut-off feature, it is recommended that you
first try lengthening the time set in "AUTO
POWER SHUT-OFF TIMER" (see below). In
most cases a suitable timer setting will allow
work to proceed with minimal delay and still
enable you to enjoy the benefits of power
conservation.
shut-off feature, it is recommended that you
first try lengthening the time set in "AUTO
POWER SHUT-OFF TIMER" (see below). In
most cases a suitable timer setting will allow
work to proceed with minimal delay and still
enable you to enjoy the benefits of power
conservation.
Note
AUTO POWER OFF
min.
(1~240)
PREHEAT MODE
min.
(1~240)
Pegasus-E_Copy_Ex.book 85 ページ 2009年7月22日 水曜日 午後2時4分
86
SYSTEM SETTINGS GUIDE
COPY SETTINGS
These programs are used to enable various copy
functions. To access one of these programs, select
"COPIER" in the mode selection screen, select the
desired program in the copy settings screen, and
press the [OK] key.
functions. To access one of these programs, select
"COPIER" in the mode selection screen, select the
desired program in the copy settings screen, and
press the [OK] key.
EXPOSURE ADJUST
This program is used to adjust the exposure level
when "AUTO" is used for the exposure mode. The
auto exposure level can be set separately for the
document glass and the SPF.
One of five levels can be selected, with the left end of
the scale the lightest level and the right end of the
scale the darkest level.
The factory default setting is the middle level.
when "AUTO" is used for the exposure mode. The
auto exposure level can be set separately for the
document glass and the SPF.
One of five levels can be selected, with the left end of
the scale the lightest level and the right end of the
scale the darkest level.
The factory default setting is the middle level.
Select "EXPOSURE ADJUST" and press the [OK] key.
The following screen will appear.
The following screen will appear.
1
Select "PLATEN" or "SPF/RSPF" with the
[
[
] or [
] key.
2
Press the [
] or [
] key to adjust the
exposure.
3
Repeat steps 1 and 2 to adjust the other
exposure.
exposure.
4
Press the [OK] key.
MARGIN DEFAULT
(When the dual function board is installed)
This is used to set the default margin width.
The factory default setting is "10 mm (1/2 inch)".
The factory default setting is "10 mm (1/2 inch)".
Select "MARGIN DEFAULT" and press the [OK] key.
The following screen will appear.
The following screen will appear.
1
Adjust the default margin width with the
[
[
] or [
] key.
The width can be set from 0 to 20 mm in increments of 5
mm (0" to 1" in increments of 1/4").
mm (0" to 1" in increments of 1/4").
2
Press the [OK] key.
ERASE ADJUST
(When the dual function board is installed)
This is used to set the default erasure width.
The factory default setting is "10 mm (1/2 inch)".
The factory default setting is "10 mm (1/2 inch)".
Select "ERASE ADJUST" and press the [OK] key. The
following screen will appear.
following screen will appear.
1
Adjust the edge erase and centre erase
width with the [
width with the [
] or [
] key.
The edge erase width and the centre erase width share
the same default value, which can be set from 0 to 20
mm in increments of 5 mm (0" to 1" in increments of
1/4").
the same default value, which can be set from 0 to 20
mm in increments of 5 mm (0" to 1" in increments of
1/4").
2
Press the [OK] key.
CARD SHOT DEFAULT
(When the dual function board is installed)
This program is used to set the default dimensions that
appear when the card shot size entry screen is displayed.
The factory default settings are 86 mm (3-3/8") for the
width (X) and 54 mm (2-1/8") for the length (Y).
appear when the card shot size entry screen is displayed.
The factory default settings are 86 mm (3-3/8") for the
width (X) and 54 mm (2-1/8") for the length (Y).
Select "CARD SHOT DEFAULT" and press the [OK]
key. The following screen will appear.
key. The following screen will appear.
1
Select X or Y with the [
] or [
] key and
adjust the corresponding default value
with the [
with the [
] or [
] key.
2
Press the [OK] key.
DEFAULT TRAY SET
This program is used to set which tray is selected by
default.
Trays that appear for selection will vary depending on
the optional trays that have been installed.
The factory default setting is "TRAY 1".
default.
Trays that appear for selection will vary depending on
the optional trays that have been installed.
The factory default setting is "TRAY 1".
EXPOSURE ADJUST
PLATEN
SPF/RSPF
MARGIN DEFAULT
mm
(0~20)
ERASE ADJUST
mm
(0~20)
CARD SHOT DEFAULT
SIZE(mm)
X:
Y:
SIZE(mm)
X:
Y:
Pegasus-E_Copy_Ex.book 86 ページ 2009年7月22日 水曜日 午後2時4分