Sharp MX-C250 / MX-C250E / MX-C250F / MX-C250FE / MX-C250FR / MX-C300F / MX-C300W / MX-C300WE / MX-C300A / MX-C300WR (serv.man2) Handy Guide ▷ View online
Test Simulation
The following pages contain information regarding test simulations. For a detailed description for
each test simulation, please refer to the MX-C250/300 series Service Manual.
Entry Code:
1
Scanner Self Test
1
Scanner operation test
2
Scanner sensor check
2
RSPF Self Test
1
SPF ageing test.
2
SPF sensor check
3
SPF output check (motor, clutch, solenoid)
5
Lamp Operation & Test
1
LCD/LED operation panel test
2
Heater lamp load check
3
Scanner lamp control circuit check
4
Discharge lamp control circuit check
6
System Load Operation & Test
1
Paper Feed output / load check
2
Fan control circuit check
3
Transport unit control circuit check
90 Reset machine to factory setting (scanner
mirror unit lock position execute).
7
Device Aging Operation & Test
1
Ageing test setting
6
Interval ageing cycle timer set up
9
Printing colour select mode (colour)
12 Document reading setting (aging)
8
High Voltage Operation & Test
1
Developer bias setting and output
2
MHV/Grid setting and output
6
Transfer setting and output
10
Toner Motor Operation & Test
1
Toner motor operation check
14
Clear / Cancel
--
Trouble cancel (excluding U2/PF trouble).
21
Maintenance Cycle Configuration
1
Maintenance cycle setting
22
Data Output & Check
1
Counter data display
2
Jam/trouble counter display
3
Jam history data display
4
Trouble code history data display
5
ROM version display
6
Data print mode
8
RSPF & Scanner output counter display
9
Paper feed counter display
10 Machine system display
11 Fax counter display
12 RSPF jam history display
12 RSPF jam history display
13 Process cartridge counter display
14 Toner cartridge use status
14 Toner cartridge use status
19 Image Send counter display
23
Data Print Mode & Check
2
Print jam/Trouble data print mode
24
Data Counter & Clear
1
Jam/trouble counter clear
2
Paper feed counter clear
3
Document feed & output counter clear
4
Maintenance counter clear
5
Developer counter clear
6
Copy Counter clear
9
Print & other counter clear
10 Fax counter clear
15 Network scanner counter clear
35 Toner cartridge use status clear
35 Toner cartridge use status clear
25
DV Auto Adjustment & Monitor
1
Toner sensor monitor (Process drive)
2
Auto developer adjustment setting
4
Toner supply quantity data display
5
Toner density correction data display
16
U2 Clear / Cancel
--
U2 trouble cancel
SHARP
Document Solution Centre
21
Test Simulation
26
Device Configuration
6
Destination set-up
18 Toner save operation
30 CE mark control setup
30 CE mark control setup
35 Trouble memory mode setting
53 Enable/Disable auto colour calibration
53 Enable/Disable auto colour calibration
54 Enable/Disable auto colour calibration for
Printer
69 Toner near end setting
73
Poster enlargement image loss adjustment
30
Sensor Operation & Test
1
Main unit sensor check
43
Fuser Setting & Adjustment
1
Fuser temperature setup for each mode
4
Fuser temperature 2. setup for each mode
20 Fuser temperature. correction for
low temperature & humidity (L/L)
21 Fuser temp correction for high
temperature & humidity (H/H)
22 Perform L/L correction for fuser
temperature setting
23 Perform H/H correction for
fuser temperature setting
24 Fuser temperature correction setting
44
Process Control Data
1
Process control mode setting
2
Process control sensitivity adjustment
4
Process control initial density setup
6
High density process control correction
9
Process control data display
12 DM data, patch/base data display
14 Fuser temp.& humidity output data
15 OPC drum idle rotation setting
15 OPC drum idle rotation setting
21 Half tone process control registration
22 Half tone process control patch result
22 Half tone process control patch result
24 Half tone correction data result display
25 Initial half tone correction data display
26 Half tone process control execution
27 Half tone process control correction clear
28 Process control timing (On/Off) setting
29 Enable/disable half tone correction during
each job
31 OPC drum deflection adjustment/check
37 DV bias correction level setting for
continuous print mode.
22
44
Process Control Data
43 DV unit installation identification check
62 Process control execution condition setting
46
Copy & Image Density Adjustment
1
Colour copy density adjustment
2
B/W copy density adjustment
4
Colour scanner density adjustment
5
B/W scanner density adjustment
9
Scan image density adjustment
19 B/W auto exposure mode setup
21 Engine colour balance adjustment (All)
21 Engine colour balance adjustment (All)
23 Enable/disable maximum density adjust.
24 Engine half tone auto adjustment
24 Engine half tone auto adjustment
27 Coefficient (Black edge) gamma set-up
32 Document background density adjust.
32 Document background density adjust.
37 B/W image reproduction adjustment
39 Fax Image send sharpness adjustment
40 Fax mode exposure adjust (All modes)
41 Fax mode exposure adjust (Normal)
42 Fax mode exposure adjust (Fine Text)
42 Fax mode exposure adjust (Fine Text)
43 Fax mode exposure adjust (Super Fine)
51 Heavy paper mode gamma adjustment
51 Heavy paper mode gamma adjustment
52 Heavy paper mode gamma default set
54 Half tone density adjustment (dither).
48
Magnification & Motor Adjustment
1
Scan image magnification ratio adjust
(Main & Sub scan)
6
Motor rotation speed adjustment
49
Firmware & E-Manual Upgrade
1
Firmware Upgrade Program
2
FPGA Update Program
50
Image Position Adjustment
1
Lead edge/copy position adjustment
5
Printer lead edge adjustment (sub scan)
6
DSPF Lead edge/copy position adjustment
10 Print off-centre deviation adjustment.
12 Original centre deviation adjustment.
20 Manual colour registration adjust.
22 Auto colour registration & drum
adjustment
SHARP
Document Solution Centre
51
Resist Roller Adjustment
1
Secondary transfer voltage ON
timing adjustment
timing adjustment
2
Resist roller adjustment
53
Document Feeder Adjustment
8
SPF scanning position adjustment
9
SPF dirt detection setting
10 SPF dirt detection execution
55
MFP Data Setting
1
Engine soft switch setting
2
Scanner soft switch setting
3
Controller soft switch setting:-
SW1-5 Auto clear function before copy
job execution:-
0 =Disabled, 1 = Enabled
SW3-6 Process mixed original size
printing for duplex mode:-
0 =Disabled, 1 = Enabled
0 =Disabled, 1 = Enabled
SW3-7 HP Compatibility Mode:-
0 =Disabled, 1 = Enabled
SW9-6 Duplex binding:-
0 = Binding OFF (Default)
1 = Binding ON
1 = Binding ON
56
MFP Data Import & Export
2
Export/Import EEPROM/SD Card &
HDD data
HDD data
5
Export Adjustment & Settings data to USB
60
Memory Operation & Test
1
SDRAM read/write test (MFP PWB)
61
LSU Writing Adjustment/Test
1
LSU test (Polygon & BD detection check)
3
LSU power auto setup
4
LSU position adjustment (CMYK)
11 Document filing data deletion
12 Enable/disable auto format for HDD
trouble
13 HDD format (manual area only)
14 Delete document filing management data
63
CCD Operation & Adjustment
1
Shading correction data display
2
Shading correction execution (force)
3
CCD gamma & colour correction adjust.
SHARP
Document Solution Centre
Test Simulation
63
CCD Operation & Adjustment
5
CCD gamma & colour correction reset.
12 B/W Image (RGB) ratio for lamp adjustment
64
Self Test Print
1
Test print (Colour mode)
2
Test print (B/W mode)
4
Printer self print test
5
Printer self print test (PCL)
6
Printer self pint test (PS)
65
LCD Operation & Adjustment
10 Displays key standby time
66
Fax Control Settings & Adjustments
1
Fax Soft SW setting
2
Country code default set (Fax)
4
Fax signal line check (Max level)
7
Fax memory printout (all data)
8
Fax sound message setup
10 Fax all memory clear
11 Voice signal check (line/speaker 300bps)
13 Register dial number for Sim 66-14/15/16
11 Voice signal check (line/speaker 300bps)
13 Register dial number for Sim 66-14/15/16
17 DTFM signal to send to line (Max level)
21 Print various registration information
30 Tel/LIU sensor status check
30 Tel/LIU sensor status check
31 ON/OFF setting of output port (Tel/LIU)
32 Received data check (comparison)
33 Busy Tone/CNG/CED/FNET detect check
34 Display time required for sending test data
67
Printer Settings & Adjustments
25 Printer half tone colour adjustment
31 Printer calibration data clear
31 Printer calibration data clear
33 Printer screen gamma adjust. (PCL/PS)
34 Engine maximum adjustment mode for
34 Engine maximum adjustment mode for
printer
36 Adjust low density section
52 Printer default gamma check (PCL/PS)
23
Trouble Codes
A0
30 Machine configuration error
C1
10 Main charger trouble (BK)
CE
00 Network communication error
01 Network controller trouble
01 Network controller trouble
02 FTP or Mail server is not found
3
Specified
server
does
not
correspond during transmission
04 Invalid account/password (FTP server)
05 Invalid directory entered (FTP server)
05 Invalid directory entered (FTP server)
06 Specified mail server (POP3) is not found
09 Email file size error
09 Email file size error
11 Scanner memory shortage
12 LDAP address number is exceeded
12 LDAP address number is exceeded
13 USB memory is not installed
14 USB memory write protect
15 Insufficient USB memory
16 USB memory I/O error
16 USB memory I/O error
17 USB memory error (Other)
E7
01 MFP image data trouble.
10 Shading trouble (Black correction).
11 Shading trouble (White correction).
14 CCD-ASIC communication error.
20 LSU laser detection error (K).
21 LSU laser detection error (C).
22 LSU laser detection error (M).
22 LSU laser detection error (M).
23 LSU laser detection error (Y).
28 LSU-PCU connection trouble
29 LSU-ASIC frequency abnormality.
38 Zoran chip AD adjustment error
80 MFP-SCU communication trouble.
90 MFP-PCU communication trouble.
91 Fax reception image data error
93 Image data process error.
93 Image data process error.
EE
EC Auto DV adjustment trouble.
EL Auto DV adjustment trouble
(over toned).
EU
Auto DV adjustment trouble
(under toned).
24
F2
22 Discharge lamp trouble (K)
23 Discharge lamp trouble (CMY)
23 Discharge lamp trouble (CMY)
39 Process temperature sensor trouble
40 Toner density sensor trouble (K)
40 Toner density sensor trouble (K)
41 Toner density sensor trouble (C)
42 Toner density sensor trouble (M)
43 Toner density sensor trouble (Y)
45 Colour image density sensor trouble
47 Ozone duct thermistor trouble
49 LSU thermistor trouble
50 K drum phase sensor trouble
49 LSU thermistor trouble
50 K drum phase sensor trouble
51 CL drum phase sensor trouble
58 Temperature/humidity sensor trouble
64 Toner supply operation trouble (K)
64 Toner supply operation trouble (K)
65 Toner supply operation trouble (C)
66 Toner supply operation trouble (M)
67 Toner supply operation trouble (Y)
70 Improper toner cartridge detection (K)
71 Improper toner cartridge detection (C)
71 Improper toner cartridge detection (C)
72 Improper toner cartridge detection (M)
73 Improper toner cartridge detection (Y)
74 Toner cartridge CRUM error (K)
74 Toner cartridge CRUM error (K)
75 Toner cartridge CRUM error (C)
76 Toner cartridge CRUM error (M)
77 Toner cartridge CRUM error (Y)
77 Toner cartridge CRUM error (Y)
78 Image density registration sensor trouble
F3
22 Paper feed tray 2 lift up trouble
F6
00 ICU-Fax communication trouble (ICU)
04 Fax modem operation trouble.
04 Fax modem operation trouble.
21 LIU & Fax soft switch error (combination)
H2
00 Thermistor open trouble (TH_UM_AD2).
02 Thermistor open trouble (TH_US).
02 Thermistor open trouble (TH_US).
3
Compensation Thermistor open trouble
(TH_UM_AD1)
(TH_UM_AD1)
H3
00 Fuser high temperature trouble (TH_UM).
2
Sub thermistor fusing section
high temperature (TH_US).
high temperature (TH_US).
SHARP
Document Solution Centre
Click on the first or last page to see other MX-C250 / MX-C250E / MX-C250F / MX-C250FE / MX-C250FR / MX-C300F / MX-C300W / MX-C300WE / MX-C300A / MX-C300WR (serv.man2) service manuals if exist.