MX-7000N  SELF DIAG AND TROUBLE CODE  8 – 17
 
F1-62
Inserter reverse sensor trouble
 
F2-02
Toner supply abnormality (K2)
 
F2-04
Toner cartridge improper (K2)
 
F2-05
Toner cartridge CRUM error (K2)
 
F2-39
Process thermistor trouble
 
F2-40
Toner empty sensor abnormality (K)
 
F2-41
Toner empty sensor abnormality (C)
 
F2-42
Toner empty sensor abnormality (M)
Trouble content
Sensor adjustment failure
Section
PCU
Case 1
Cause
Sensor trouble, harness disconnection, finisher 
control PWB trouble, inserter control PWB trouble
Check and 
remedy
Use SIM3-2 to check the operation of the inlet port 
cover open/close sensor and the paper exit cover 
open/close sensor.
Replace the finisher control PWB.
Replace the inserter control PWB.
Trouble content
Toner end with the remaining quantity of 25% or 
more.
The toner supply time exceeds 5 times as much as 
the specified time.
Section
PCU
Case 1
Cause
Toner motor section connector harness trouble
Check and 
remedy
Check the connector connection of the toner motor 
section.
Check the connector harness (TM) connection to 
the main PWB.
Case 2
Cause
Toner motor and toner density sensor trouble.
Piezoelectric sensor abnormality
Check and 
remedy
1)
Check the toner density sensor output. 
(SIM25-1)
2)
Check that the toner transport pipe is not 
clogged between the toner cartridge and the 
developing unit. Replace the toner cartridge 
(CRUM) if necessary. Intermediate hopper 
replacement
3)
If replacement of the toner cartridge (CRUM) 
does not clear the trouble, check the 
developing unit.
Trouble content
Improper data are detected in the CRUM contents 
when the normal CRUM of the cartridge is 
detected.
Section
PCU
Case 1
Cause
An improper cartridge is inserted.
Toner cartridge trouble
Check and 
remedy
Replace the toner cartridge.
Trouble content
CRUM cannot be read or written.
Section
PCU
Case 1
Cause
Connection trouble or disconnection of the 
connector and the harness between the PCU and 
the toner cartridge.
Check and 
remedy
Check the connector and the harness between the 
PCU and the toner cartridge.
Case 2
Cause
CRUM trouble
Check and 
remedy
Replace the toner cartridge.
Case 3
Cause
PCU PWB trouble
Check and 
remedy
Replace the PCU PWB.
Trouble content
Process thermistor open
Section
PCU
Case 1
Cause
Process thermistor harness connection trouble
Check and 
remedy
Check the connection of the harness and 
connector of the process thermistor.
Case 2
Cause
Process thermistor trouble
Check and 
remedy
Check the connection of the harness and 
connector of the process thermistor.
Case 3
Cause
PCU PWB trouble
Check and 
remedy
Check the PCU PWB.
Trouble content
Toner empty sensor output abnormality. Sample 
level 25 or less or 231 or above.
Section
PCU
Case 1
Cause
The connector is not installed.
Check and 
remedy
Check the connection of the connector harness to 
the PCU PWB. Check the connection of the toner 
empty sensor. 
Case 2
Cause
Connector harness trouble
Check and 
remedy
Check the harness disconnection.
Case 3
Cause
Cartridge trouble
Check and 
remedy
Check the cartridge connection.
Trouble content
Toner empty sensor output abnormality. Sample 
level 25 or less or 231 or above.
Section
PCU
Case 1
Cause
The connector is not installed.
Check and 
remedy
Check the connection of the connector harness to 
the PCU PWB. Check the connection of the toner 
empty sensor. 
Case 2
Cause
Connector harness trouble
Check and 
remedy
Check the harness disconnection.
Case 3
Cause
Cartridge trouble
Check and 
remedy
Check the cartridge connection.
Trouble content
Toner empty sensor output abnormality. Sample 
level 25 or less or 231 or above.
Section
PCU
Case 1
Cause
The connector is not installed.
Check and 
remedy
Check the connection of the connector harness to 
the PCU PWB. Check the connection of the toner 
empty sensor. 
Case 2
Cause
Connector harness trouble
Check and 
remedy
Check the harness disconnection.
Case 3
Cause
Cartridge trouble
Check and 
remedy
Check the cartridge connection.
MX-7000N  SELF DIAG AND TROUBLE CODE  8 – 18
 
F2-43
Toner empty sensor abnormality (Y)
 
F2-44
Black exclusive image density sensor
trouble (Transfer belt surface 
reflection ratio abnormality)
 
F2-45
Color exclusive image density sensor
trouble (Calibration plate surface 
reflection ratio abnormality)
 
F2-49
LSU thermistor trouble
 
F2-50
K phase sensor sensing trouble
 
F2-51
CL phase sensor sensing trouble (C)
Trouble content
Toner empty sensor output abnormality. Sample 
level 25 or less or 231 or above.
Section
PCU
Case 1
Cause
The connector is not installed.
Check and 
remedy
Check the connection of the connector harness to 
the PCU PWB. Check the connection of the toner 
empty sensor. 
Case 2
Cause
Connector harness trouble
Check and 
remedy
Check the harness disconnection.
Case 3
Cause
Cartridge trouble
Check and 
remedy
Check the cartridge connection.
Trouble content
The transfer belt surface is scanned by the image 
density sensor before starting the process control, 
and adjust the sensor gain so that the output is 
kept at a certain level. However, the output is not 
within the specified range though the senor gain is 
adjusted.
Section
PCU
Case 1
Cause
Image density sensor trouble, harness connection 
trouble between PCU PWB and the image density 
sensor, image density sensor dirt, transfer belt 
cleaning trouble, calibration plate solenoid 
operation trouble
Check and 
remedy
Use SIM44-2 to execute the process control 
sensor gain adjustment. If "ERROR" is displayed, 
check the sensor, the  harness and the calibration 
plate solenoid operation for any trouble. If the 
adjustment is completed, check the transfer belt 
surface state. 
Trouble content
The calibration plate surface is scanned by the 
image density sensor before starting the process 
control, and adjust the sensor gain so that the 
output is kept at a certain level. However, the 
output is not within the certain level though the 
senor gain is adjusted.
Section
PCU
Case 1
Cause
Image density sensor trouble, harness connection 
trouble between PCU PWB and the image density 
sensor, image density sensor dirt, calibration plate 
dirt, calibration plate solenoid operation trouble
Check and 
remedy
Use SIM44-2 to execute the process control 
sensor gain adjustment. If "ERROR" is displayed, 
check the sensor and the harness operation for 
any trouble. If the adjustment is completed, check 
the calibration plate solenoid operation.
Trouble content
The detection temperature is out of the range of 
-28
°C to 78°C.
Section
PCU
Case 1
Cause
LSU thermistor harness connection trouble
Check and 
remedy
Check the connection of the LSU thermistor 
harness and connector.
Case 2
Cause
LSU thermistor trouble, PCU PWB trouble
Check and 
remedy
Replace the LSU thermistor. Replace the PCU 
PWB.
Trouble content
Detection is made by interruption of light in the 
sensor section of the projection rib on the drum 
drive gear to control the BK drum phase. The 
detection signal cannot be acquired and phase 
control cannot be made.
Section
PCU
Case 1
Cause
Sensor connector connection trouble
Check and 
remedy
Check the sensor connector connection.
Case 2
Cause
Dirt on the sensor light emitting section, or 
installation trouble
Check and 
remedy
Check for dirt on the sensor or check the 
installation state.
Case 3
Cause
Drum drive gear upper rib breakage, sensor 
trouble
Check and 
remedy
If there is no trouble in the rib, replace the sensor. 
(Use SIM30-1 "DHPD_K" to check interruption or 
transmission of light.)
Trouble content
Detection is made by interruption of light in the 
sensor section of the projection rib on the drum 
drive gear to control the color drum (C) phase. The 
detection signal cannot be acquired and phase 
control cannot be made.
Section
PCU
Case 1
Cause
Sensor connector connection trouble
Check and 
remedy
Check the sensor connector connection.
Case 2
Cause
Dirt on the sensor light emitting section, or 
installation trouble
Check and 
remedy
Check for dirt on the sensor or check the 
installation state.
Case 3
Cause
Drum drive gear upper rib breakage, sensor 
trouble
Check and 
remedy
If there is no trouble in the rib, replace the sensor. 
(Use SIM30-1 "DHPD_C" to check interruption or 
transmission of light.)
MX-7000N  SELF DIAG AND TROUBLE CODE  8 – 19
 
F2-52
CL phase sensor sensing trouble (M)
 
F2-53
CL phase sensor sensing trouble (Y)
 
F2-58
Process humidity sensor trouble
 
F2-64
Toner supply abnormality (K)
 
F2-65
Toner supply abnormality (C)
 
F2-66
Toner supply abnormality (M)
Trouble content
Detection is made by interruption of light in the 
sensor section of the projection rib on the drum 
drive gear to control the color drum (M) phase. The 
detection signal cannot be acquired and phase 
control cannot be made.
Section
PCU
Case 1
Cause
Sensor connector connection trouble
Check and 
remedy
Check the sensor connector connection.
Case 2
Cause
Dirt on the sensor light emitting section, or 
installation trouble
Check and 
remedy
Check for dirt on the sensor or check the 
installation state.
Case 3
Cause
Drum drive gear upper rib breakage, sensor 
trouble
Check and 
remedy
If there is no trouble in the rib, replace the sensor. 
(Use SIM30-1 "DHPD_M" to check interruption or 
transmission of light.)
Trouble content
Detection is made by interruption of light in the 
sensor section of the projection rib on the drum 
drive gear to control the color drum (Y) phase. The 
detection signal cannot be acquired and phase 
control cannot be made.
Section
PCU
Case 1
Cause
Sensor connector connection trouble
Check and 
remedy
Check the sensor connector connection.
Case 2
Cause
Dirt on the sensor light emitting section, or 
installation trouble
Check and 
remedy
Check for dirt on the sensor or check the 
installation state.
Case 3
Cause
Drum drive gear upper rib breakage, sensor 
trouble
Check and 
remedy
If there is no trouble in the rib, replace the sensor. 
(Use SIM30-1 "DHPD_Y" to check interruption or 
transmission of light.)
Trouble content
Process humidity sensor open
Section
PCU
Case 1
Cause
Process humidity sensor harness connection 
trouble
Check and 
remedy
Check the harness and connector connection of 
the process humidity sensor.
Case 2
Cause
Process humidity sensor trouble
Check and 
remedy
Check the process humidity sensor.
Case 3
Cause
PCU PWB trouble
Check and 
remedy
Check the PCU PWB.
Trouble content
Toner end with the remaining quantity of 25% or 
more.
The toner supply time exceeds 5 times as much as 
the specified time.
Section
PCU
Case 1
Cause
Toner motor section connector harness trouble
Check and 
remedy
Check the connector connection of the toner motor 
section.
Check the connector harness (TM) connection to 
the main PWB.
Case 2
Cause
Toner motor and toner density sensor trouble.
Piezoelectric sensor abnormality
Check and 
remedy
1)
Check the toner density sensor output. 
(SIM25-1)
2)
Check that the toner transport pipe is not 
clogged between the toner cartridge and the 
developing unit. Replace the toner cartridge 
(CRUM) if necessary. Intermediate hopper 
replacement
3)
If replacement of the toner cartridge (CRUM) 
does not clear the trouble, check the 
developing unit.
Trouble content
Toner end with the remaining quantity of 75% or 
more.
The toner supply time exceeds 3 times as much as 
the specified time.
Section
PCU
Case 1
Cause
Toner motor section connector harness trouble
Check and 
remedy
Check the connector connection of the toner motor 
section.
Check the connector harness (TM) connection to 
the main PWB.
Case 2
Cause
Toner motor and toner density sensor trouble
Check and 
remedy
1)
Check the toner density sensor output. 
(SIM25-1)
2)
Check that the toner transport pipe is not 
clogged between the toner cartridge and the 
developing unit. Replace the toner cartridge 
(CRUM) if necessary.
3)
If replacement of the toner cartridge (CRUM) 
does not clear the trouble, check the 
developing unit.
Trouble content
Toner end with the remaining quantity of 75% or 
more.
The toner supply time exceeds 3 times as much as 
the specified time.
Section
PCU
Case 1
Cause
Toner motor section connector harness trouble
Check and 
remedy
Check the connector connection of the toner motor 
section.
Check the connector harness (TM) connection to 
the main PWB.
Case 2
Cause
Toner motor and toner density sensor trouble
Check and 
remedy
1)
Check the toner density sensor output. 
(SIM25-1)
2)
Check that the toner transport pipe is not 
clogged between the toner cartridge and the 
developing unit. Replace the toner cartridge 
(CRUM) if necessary.
3)
If replacement of the toner cartridge (CRUM) 
does not clear the trouble, check the 
developing unit.
MX-7000N  SELF DIAG AND TROUBLE CODE  8 – 20
 
F2-67
Toner supply abnormality (Y)
 
F2-70
Toner cartridge improper (K)
 
F2-71
Toner cartridge improper (C)
 
F2-72
Toner cartridge improper (M)
 
F2-73
Toner cartridge improper (Y)
 
F2-74
Toner cartridge CRUM error (K)
 
F2-75
Toner cartridge CRUM error (C)
 
F2-76
Toner cartridge CRUM error (M)
 
F2-77
Toner cartridge CRUM error (Y)
Trouble content
Toner end with the remaining quantity of 75% or 
more.
The toner supply time exceeds 3 times as much as 
the specified time.
Section
PCU
Case 1
Cause
Toner motor section connector harness trouble
Check and 
remedy
Check the connector connection of the toner motor 
section.
Check the connector harness (TM) connection to 
the main PWB.
Case 2
Cause
Toner motor and toner density sensor trouble
Check and 
remedy
1)
Check the toner density sensor output. 
(SIM25-1)
2)
Check that the toner transport pipe is not 
clogged between the toner cartridge and the 
developing unit. Replace the toner cartridge 
(CRUM) if necessary.
3)
If replacement of the toner cartridge (CRUM) 
does not clear the trouble, check the 
developing unit.
Trouble content
Improper data are detected in the CRUM contents 
when the normal CRUM of the cartridge is 
detected.
Section
PCU
Case 1
Cause
An improper cartridge is inserted.
Toner cartridge trouble
Check and 
remedy
Replace the toner cartridge.
Trouble content
Improper data are detected in the CRUM contents 
when the normal CRUM of the cartridge is 
detected.
Section
PCU
Case 1
Cause
An improper cartridge is inserted.
Toner cartridge trouble
Check and 
remedy
Replace the toner cartridge.
Trouble content
Improper data are detected in the CRUM contents 
when the normal CRUM of the cartridge is 
detected.
Section
PCU
Case 1
Cause
An improper cartridge is inserted.
Toner cartridge trouble
Check and 
remedy
Replace the toner cartridge.
Trouble content
Improper data are detected in the CRUM contents 
when the normal CRUM of the cartridge is 
detected.
Section
PCU
Case 1
Cause
An improper cartridge is inserted.
Toner cartridge trouble
Check and 
remedy
Replace the toner cartridge.
Trouble content
CRUM cannot be read or written.
Section
PCU
Case 1
Cause
Connection trouble or disconnection of the 
connector and the harness between the PCU and 
the toner cartridge.
Check and 
remedy
Check the connector and the harness between the 
PCU and the toner cartridge.
Case 2
Cause
CRUM trouble
Check and 
remedy
Replace the toner cartridge.
Case 3
Cause
Control (PCU) PWB trouble
Check and 
remedy
Replace the PCU PWB.
Trouble content
CRUM cannot be read or written.
Section
PCU
Case 1
Cause
Connection trouble or disconnection of the 
connector and the harness between the PCU and 
the toner cartridge.
Check and 
remedy
Check the connector and the harness between the 
PCU and the toner cartridge.
Case 2
Cause
CRUM trouble
Check and 
remedy
Replace the toner cartridge.
Case 3
Cause
Control (PCU) PWB trouble
Check and 
remedy
Replace the PCU PWB.
Trouble content
CRUM cannot be read or written.
Section
PCU
Case 1
Cause
Connection trouble or disconnection of the 
connector and the harness between the PCU and 
the toner cartridge.
Check and 
remedy
Check the connector and the harness between the 
PCU and the toner cartridge.
Case 2
Cause
CRUM trouble
Check and 
remedy
Replace the toner cartridge.
Case 3
Cause
Control (PCU) PWB trouble
Check and 
remedy
Replace the PCU PWB.
Trouble content
CRUM cannot be read or written.
Section
PCU
Case 1
Cause
Connection trouble or disconnection of the 
connector and the harness between the PCU and 
the toner cartridge.
Check and 
remedy
Check the connector and the harness between the 
PCU and the toner cartridge.
Case 2
Cause
CRUM trouble
Check and 
remedy
Replace the toner cartridge.
Case 3
Cause
Control (PCU) PWB trouble
Check and 
remedy
Replace the PCU PWB.