DOWNLOAD Sharp MX-2640N / MX-2640NR / MX-2640FN / MX-3140N / MX-3140NR / MX-3140FN / MX-3640N / MX-3640NR / MX-3640FN (serv.man168) Service Manual ↓ Size: 26.65 KB | Pages: 3 in PDF or view online for FREE

Model
MX-2640N MX-2640NR MX-2640FN MX-3140N MX-3140NR MX-3140FN MX-3640N MX-3640NR MX-3640FN (serv.man168)
Pages
3 Few pages! See other manuals at the bottom of the first or last page.
Size
26.65 KB
Type
PDF
Document
Service Manual / Technical Bulletin
Brand
Device
Copying Equipment / Combined MFP Firmware Version ICUM BOOT MAIN03.00.A2.00 ICUM MAIN 03.00.A2.00- C00 Jan 14 - Bulletin Only
File
mx-2640n-mx-2640nr-mx-2640fn-mx-3140n-mx-3140nr-mx.pdf
Date

Sharp MX-2640N / MX-2640NR / MX-2640FN / MX-3140N / MX-3140NR / MX-3140FN / MX-3640N / MX-3640NR / MX-3640FN (serv.man168) Service Manual / Technical Bulletin ▷ View online

 
 
 
 
Technical Report
 
DIGITAL FULL COLOR COPIER(OPTION) : MX-2640N/3140N/3640N 
No.  : CCE-1254
Date : Jan. 10, 2014
 
C
Document Systems Unit 
1/3 
SHARP CORPORATION
ROM UPGRADE ..... (8). 
 
1. Model Name: MX-2640N/3140N/3640N 
(Except 
for 
Taiwan) 
 
2. Description: 
Upgrade of ICUM, ICU, PCU-ROM, and E-Manual 
From mid-December 2013 production 
ROM Control No 
ICUM 
ICU 
PCU 
SCU 
FAX 
E-Manual
C00 
0300A200
0300A200
0402G200
0100A200 0101G100 0140A200
  * ICUM above is the version described in the ROM management label. Check that the actual   
    version is: ICUM(MAIN): 03.00.A2.00/ICUM(SUB): 03.00.A2.00/LANGUAGE: 01.42.S1.00/ 
  UICONTENTS: 03.00.A2.00/PCL(PROFILE): 01.00.A2.00 in SIM22-5. 
    ICU is also the version described in the ROM management label. Check that the actual version 
  is: ICU(MAIN): 03.00.A2.00/ICU(BOOT): 01.01.A2.00/ICU(SUB): 01.03.A2.0a in SIM22-5.   
    Item of change: See the attached sheets.   
  Note) If the fusing temperature setting value of SIM43-1 is changed due to the action   
            from T/R No. CCE-1229, please be sure to return the value to the default (0) for   
      both Plain Paper/Recycled paper. 
 
 
 
 
ROM Version Combination History Table 
No. 
ROM 
Control No. 
ICUM ICU  PCU SCU  FAX 
E-Manual 
Action T/R 
No 
(7) B02 0210A200 
0200A200 0401G200 0100A200 0101G100 0130A200 
2013/9Mid
CCE-1191
(6) B01 0201A200 
0200A200 0305G200 0100A200 0101G100 0130A200 
2013/7Mid
CCE-1172
(5) B00 0200A200 
0200A200 0305G200 0100A200 0101G100 0130A200 
2013/7Mid
CCE-1162
(4) A03 0120A20a 
0120A200 0201G200 0100A200 0101G100 0110A200 
2013/2Mid
CCE-1127
(3) A03 0120A20a 
0120A200 0201G200 0100A200 0101G100 0110A200 
2013/2Mid
(2) A02 0101A200 
0100A200 0201G200 0100A200 0101G100 0110A200 
2012/12Mid CCE-1108
(1) A01 0100A20a 
0100A200 0201G200 0100A200 0101G100 0110A200 
2012/11Mid CCE-1103
 
 
 
 
 
2/3 
[Description] 
No. Item 
Details 
Specification 
OSA4.5 has been supported. 
Specification 
Support for Sharpdesk Mobile is implemented. 
3 Specification 
Modification has been made to be able to use Job Build except the switching of 
Color/B&W when using Vender Mode. 
4 UI 
[Delete] is added to Action Panel on Preview screen so that user can delete received 
data on this screen. 
5 UI 
The image quality when the image is enlarged on Preview screen for received Fax data 
has been improved. 
6 UI 
To improve confirmation method of Send/Receive Status, [Check Send/Receive Status] is 
added to the Action Panel of base screen for Image Send. Job Status screen appears by 
selecting this item. 
7 UI 
When entering the address in Image Send mode, the number of address used to be 
displayed on the left side of "+" key from the 2nd entry but the modification has been 
made to display from 1st entry. 
8 UI 
When Document Filing print was prohibited, [Print Now] key in Document Filing was 
grayed out.      This problem has been corrected.     
9 UI 
In Print from Network Folder mode, when folder path is entered directly, folder path/ user 
name/ password were all cleared if the connection to Network folder failed and the data 
had to be entered again when retrying.    To improve this situation, the modification has 
been made to maintain these information until the print from Network folder is completed.
10 UI 
If Home key is registered in Home Screen Settings on web page, registered Home key is 
not displayed if user authentication is enabled. This problem is corrected. 
11 UI 
The modification is made to illuminate the key when pressing the key like software 
keyboard etc so that the users can easily recognize they have pressed the button. 
12 UI 
When entering texts using the certain OSA application, the characters are overlapped if 
the characters are input from the external keyboard. This problem has been corrected. 
13 UI 
Modification of incorrect German translation in System Settings -> Device Control -> 
Registration Adjustment 
14 Image 
send 
MFP displays the message “Receiving” for Fax data but never output the data. This 
problem has been corrected. 
15 Image 
send 
NG16 error occurred while receiving Fax data. Machine is in wait condition and never 
output the data. This problem has been corrected. 
16 Image 
send 
If multiple numbers of received Fax data are being transferred on Preview screen in a 
batch manually, these jobs are stuck waiting for the start of the transfer. This problem has 
been corrected. 
17 Printer 
It takes too long to output particular PDF file by Direct Print. This problem has been 
corrected. 
18 
Printer 
Unable to perform Direct Print with particular PDF file. This problem has been corrected.
19 Printer 
Modification for the problem that the warning icon "waste-receptacle-full" is displayed 
when printing with Mac OS 10.8.3 + PPD. 
20 Printer 
Modification for the problem that the line is generated on the gradation area of dark color 
when printing out with Toner Save being enabled. 
21 Printer 
If the mix of monochrome and color data was printed from Linux, all the data were 
counted as color. This problem has been corrected. 
22 
Main unit Web 
The address registered to a Group disappeared when it is done on web page displayed 
on main unit panel. This problem has been corrected. 
23 
Main unit Web 
Description on “encryption level” has been added to "Security Settings" -> "SSL Settings" 
-> "Client Port" on web page. 
24 
Main unit Web 
Setting items for extended platform/ usage of proxy are not displayed in the external 
account application settings. This problem has been corrected. 
25 
Main unit control 
Main unit occasionally locked up while performing Print job (“Hold only”) while displaying 
thumbnail list in Document Filing. This problem has been corrected. 
26 
Main unit control 
Modification of occasional machine lockup after deleting a job. The machine locked up 
displaying “Please wait.” 
 
 
 
 
3/3 
 
No. Item 
Details 
27 
Main unit control 
Downloading of Device Cloning data fails if IE 10 is used. This problem has been 
corrected. 
28 
Main unit control 
There were some cases where the color of the output result changed in the process of 
continuous printing.    This problem has been corrected.
 
29 
Main unit control 
Currently the fuser pressure release operation is performed in 90 seconds after the 
machine enters the ready state but the start time of fuser pressure release has been 
changed to 120 minutes to enhance the life of the pressure spring. 
*It is confirmed that no flat spot (unrecoverable deformation of the roller) is caused by 
this countermeasure.
 
30 
Main unit control 
Fusing trouble is caused because of the adjustment to lower the fusing temperature 
when the detection temperature of the machine reaches 27-degree or higher.    For the 
countermeasure of this issue, the modification has been made not to perform this 
adjustment. 
 
Note) If the fusing temperature setting value of SIM43-1 is changed due to the action 
from T/R No. CCE-1229, please be sure to return the value to the default (0) for both 
Plain Paper/Recycled paper.
 
31 
Main unit control 
Though the setting range of the preheat mode is 1 – 60 minutes on Administrator 
Settings List, it is printed as 1 – 240 minutes. This problem has been corrected. 
32 
Main unit control 
Forced tray switch does not function if Printer job is performed in parallel vendor mode. 
This problem has been corrected. 
33 
Main unit control 
Occasionally, toner quantity jumps to 5%. This problem has been corrected. 
34 
Main unit control 
For the paper whose width is less than A4R in NN/NH/HH environment, the secondary 
transfer current is reduced and also Soft SW which enables to set PTC to the low-output 
is added.   
 
SIM55-1: 
27-6 Default: 0(OFF): 1 (ON: when printing in B/W) 
27-7 Default: 0(OFF): 1 (ON: when printing in Color)
 
35 
Main unit control 
A new Simulation mode has been developed to conform to new standard of "Blue Angel" 
(eco-label for Germany). The check box for Auto power shut off mode is not displayed 
when this mode is enabled that machine enters Auto power shut off mode at any time. 
 
Sim26-50 POWER SHUT-OFF SET 
 
While checkbox is not displayed: The machine is under factory default condition for 
EUROPE/UK. 
While displayed: The machine is under factory default condition for those other than 
EUROPE/UK. 
36 
Simulation 
Modification is made so that U2-00 error can be cancelled in SIM16. 
 
 
Display

Sharp MX-2640N / MX-2640NR / MX-2640FN / MX-3140N / MX-3140NR / MX-3140FN / MX-3640N / MX-3640NR / MX-3640FN (serv.man168) Service Manual / Technical Bulletin ▷ Download

  • DOWNLOAD Sharp MX-2640N / MX-2640NR / MX-2640FN / MX-3140N / MX-3140NR / MX-3140FN / MX-3640N / MX-3640NR / MX-3640FN (serv.man168) Service Manual ↓ Size: 26.65 KB | Pages: 3 in PDF or view online for FREE
  • Here you can View online or download the Service Manual / Technical Bulletin for the Sharp MX-2640N / MX-2640NR / MX-2640FN / MX-3140N / MX-3140NR / MX-3140FN / MX-3640N / MX-3640NR / MX-3640FN (serv.man168) in PDF for free, which will help you to disassemble, recover, fix and repair Sharp MX-2640N / MX-2640NR / MX-2640FN / MX-3140N / MX-3140NR / MX-3140FN / MX-3640N / MX-3640NR / MX-3640FN (serv.man168) Copying Equipment. Information contained in Sharp MX-2640N / MX-2640NR / MX-2640FN / MX-3140N / MX-3140NR / MX-3140FN / MX-3640N / MX-3640NR / MX-3640FN (serv.man168) Service Manual / Technical Bulletin (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.