49
GENERAL
 INFORMA
TION
The TD cartridge is not installed. Install the
TD cartridge.
Side cover is open.
Close the front and side covers securely.
The TD cartridge must be replaced. See page
27, TD CARTRIDGE REPLACEMENT.
A misfeed has occurred. See page 31,
MISFEED REMOVAL.
Toner replenishment takes up to 2 minutes.
Wait until the START key indicator stops
blinking.
Connect the copier to a power outlet which
is not used for other electric appliances.
Is 
 blinking in the copy
quantity display?
Is 
 steadily lit in the copy
quantity display?
Is the 
 indicator blinking?
Is the 
 indicator blinking?
Is the START key indicator
blinking?
Is the same power outlet used for
the lighting fixture and the copier?
Problem
  Solution
Power is on but copying
is not possible.
Lighting fixture flickers.
Copier trouble?
Self-diagnostic function
An automatic self-diagnostic function is built into the copier. Should the
copier malfunction, the self-diagnostic function will locate the problem and
stop the copier to prevent damage. An alphanumeric code will appear in the
copy quantity display.
Example
Should the copier completely stop and a letter and a number appear alternately,
contact your SHARP service centre immediately.
COPIER TROUBLE?
Be sure to use only genuine SHARP parts and supplies.
Please contact your SHARP service centre immediately if a problem persists
after checking the above.
50
GENERAL
 INFORMA
TION
SUPPLIES
Types and sizes of copy paper
Size
Weight
Capacity
Special paper
(80 
g
/m
2
 paper)
Paper trays
A5* to A3
56 to 80 g/m
2
250 sheets
Bypass tray
Ordinary paper:
56 to 128 g/m
2
**
100 sheets
Transparency film, labels,
A6 to A3
(Ordinary paper)
envelopes***
Envelopes:
International DL
(110 x 220 mm)
International C5
(162 x 229 mm)
Commercial 10
(4-1/8" x 9-1/2")
*
A5 copy paper can be used in the uppermost paper tray but cannot be used
in other trays (including trays in optional paper feed units).
** For paper weighing from 105 to 128 g/m
2
, A4 is the maximum size that
can be fed through the bypass tray.
*** Do not use envelopes that have metal clasps, plastic snappers, string
closures, windows, linings, self-adhesive patches or synthetic materials.
These will cause physical damage to the copier.
For best results, use only paper recommended by SHARP.
Special papers except envelopes must be fed one sheet at a time through
the bypass tray. Up to 10 envelopes can be set at one time.
Supplies
51
GENERAL
 INFORMA
TION
SUPPLIES
Genuine supplies statement
Standard supplies for this copier that are to be replaced by the user are copy
paper, TD cartridge, and drum cartridge.
For best copying results, be sure to use only
SHARP products.
Only genuine SHARP consumables carry the
Genuine Supplies label.
GENUINE SUPPLIES
Proper storage
1.
Store the supplies in a location that is:
clean and dry,
at a stable temperature,
not exposed to direct sunlight.
2.
Store copy paper in the wrapper and lying flat.
Paper stored out of the wrapper or in packages standing on end may
curl or get damp, resulting in paper misfeeds.
Supplies
52
GENERAL
 INFORMA
TION
Type
Digital copying machine, desktop
Copy system
Dry, electrostatic transfer
Originals
Sheets, bound documents
Original sizes
Max. A3
Copy sizes
Max. A3
Min. A6
Image loss: Max. 4 mm (leading and trailing edges)
Max. 4 mm (along other edges in total)
Copying speed
20 copies/min. (A4)
 (at 100% copy ratio)
14 copies/min. (A4R)
12 copies/min. (B4)
11 copies/min. (A3)
Continuous copy
Max. 99 copies; subtractive counter
First-copy time
7.2 sec. (except in a power save mode)
Warm-up time
Approx. 35 sec.
Copy ratio
Variable: 50% to 200%, in 1% increments (total 151 steps)
Fixed preset: 50%, 70%, 81%, 86 %, 100%, 115%, 122%,
141%, 200%
Exposure system
Moving optical source, slit exposure (stationary platen) with
automatic exposure function
Copy paper feed
Two paper trays with automatic feed  (250 sheets each), one
bypass tray with automatic feed (100 sheets)
Fusing system
Heat rollers
Developer system
Magnetic brush development
Light source
Xenon lamp
Resolution
Scan: 400 dpi
Output: 600 dpi
Gradation
Scan: 256 levels
Output: 2 levels
Power supply
AC 230 V, 50 Hz, 6 amperes
Power consumption
Max. 1.5 kW
Overall dimensions
590 mm (W) x 531 mm (D)
(with bypass tray folded)
SPECIFICATIONS
Specifications
Page of 18