AR-M550/M620  SIMULATION  8 - 46
Operation/Procedure
The operating conditions of sensors and detectors are displayed.
The active sensors and detectors are highlighted.
The paper width size detection level is displayed.
Operation/Procedure
1) Open the manual paper feed guide to the max. width.
2) Select MAX POSITION with 10-key.
3) Press [START] key.
The max. width detection level is recognized.
4) Press [CUSTOM SETTINGS] key.
5) Set the manual paper feed guide to A4R size width.
6) Select POSITION with 10-key.
7) Press [START] key.
The A4R width detection level is recognized.
8) Press [CUSTOM SETTINGS] key.
9) Set the manual paper feed guide to A5 size width.
10) Select POSITION2 with 10-key.
11) Press [START] key.
The A5 width detection level is recognized.
12) Press [CUSTOM SETTINGS] key.
13) Open the manual paper feed guide to the min. width.
14) Select MIN POSITION with 10-key.
15) Press [START] key.
The min. width detection level is recognized.
If the above procedures are not completed normally, "ERROR" is dis-
played. If completed normally, "COMPLETE" is displayed.
Operation/Procedure
1) Select the number corresponding to the set item with 10-key.
2) Press [START] key.
3) Enter the set value with 10-key.
4) Press [START] key.
40
40-1
Purpose
Operation test/Check
Function
(Purpose)
Used to check the operation of the manual feed tray 
paper size detector and the related circuit. (The 
operation of the manual feed tray paper size detector 
can be monitored with the LCD display.)
Section
Paper feed
Item
Operation
MPLD1
Manual tray length detection 1
MPLD2
Manual tray length detection 2
MTOP1
Manual tray pull-out detection 1
MTOP2
Manual tray pull-out detection 2
BYPASS_WIDTH
Manual feed guide plate position
BYPASS_AD
Manual feed width detection volume output AD 
value
Bypass Tray width 
size
(Manual tray detection size is displayed.)
A4/A3, 11 x, B5/B4, 8.5 x , A4R, B5R, A5R, 
5.5x, 7.25x, EXTRA
40-2
Purpose
Adjustment
Function
(Purpose)
Used to adjust the manual paper feed tray paper width 
detector detection level.
Section
Paper feed
Item
Operation
SIMULATION 40-1
BYPASS TRAY SENSOR CHECK..
MPLD1
     MPLD2     MTOP1     MTOP2
BYPASS_WIDTH: 
2100
       BYPASS_AD: 
600
(Bypass Tray width size: 
A4/A3
)
Select 4 and press [START] key.
Press [CUSTOM SETTINGS] key.
40-7
Purpose
Adjustment/Setup
Function
(Purpose)
Used to enter the manual paper feed tray paper width 
adjustment value.
Section
Paper feed
Item
Operation
1
MAX. POSITION
Max. width
2
POSITION 1
Adjustment point 1
3
POSITION 2
Adjustment point 2
4
MIN. POSITION
Min. value
Press [START] key.
Press [CUSTOM SETTINGS] key.
SIMULATION 40-2
BYPASS TRAY ADJUSTMENT. SELECT 1-4, AND PRESS START.
1. MAX. POSITION
2. POSITION 1
3. POSITION 2
4. MIN. POSITION
1
SIMULATION 40-2
BYPASS TRAY ADJUSTMENT.
MAX. POSITION ··· COMPLETE (or "ERROR")
Press [CUSTOM SETTINGS] key.
SIMULATION 40-2
BYPASS TRAY ADJUSTMENT.
POSITION 1 ··· COMPLETE (or "ERROR")
Select 1 and press [START] key.
SIMULATION 40-2
BYPASS TRAY ADJUSTMENT.
POSITION 2 ··· COMPLETE (or "ERROR")
Press [CUSTOM SETTINGS] key.
Press [CUSTOM SETTINGS] key. 
Select 2 and press [START] key.
Select 3 and press [START] key.
SIMULATION 40-2
BYPASS TRAY ADJUSTMENT.
MIN. POSITION ··· COMPLETE (or "ERROR")
SIMULATION 40-7
1
BYPASS TRAY VALUE SETTING. SELECT 1-4, AND PRESS START.
1. MAX. POSITION :   
72
2. POSITION 1  :    
380
3. POSITION 2  :    
710
4. MIN. POSITION :  
804
SIMULATION 40-7
BYPASS TRAY VALUE SETTING. INPUT VALUE 0-1023, AND PRESS
START.
1. MAX. POSITION
72
AR-M550/M620  SIMULATION  8 - 47
Operation/Procedure
The operating conditions of sensors and detectors are displayed.
The active sensors and detectors are highlighted.
The paper width detection level is also displayed.
Operation/Procedure
1) Open the paper feed tray 2 paper feed guide to the max. width
position.
2) Select MAX POSITION with 10-key.
3) Press [START] key.
The max. width detection level is recognized.
4) Press [CUSTOM SETTINGS] key.
5) Open the paper feed tray 3 paper feed guide to the min. width posi-
tion.
6) Select MIN POSITION with 10-key.
7) Press [START] key.
The min. width detection level is recognized.
If the above procedures are not completed normally, "ERROR" is dis-
played. If completed normally, "COMPLETE" is displayed.
Operation/Procedure
The operating conditions of sensors and detectors are displayed.
The active sensors and detectors are highlighted.
Operation/Procedure
1) Open the document cover and select NO ORIGINAL with 10-key
without placing any document on the document table.
2) Press [START] key.
The sensor level is set without document on the document table.
3) Place an A3 document on the document table, and select A3
ORIGINAL with 10-key.
4) Press [START] key.
The sensor level is set when detection the document.
If the above procedures are not completed normally, "ERROR" is dis-
played. If completed normally, "COMPLETE" is displayed.
40-11
Purpose
Operation test/Check
Function
(Purpose)
Used to check the multi-purpose tray width detection
adjustment value.
Section
Paper feed
Item
Operation
M1SS1
MPT size detection 1
M1SS2
MPT size detection 2
M1SS3
MPT detection size 3
M1SS4
MPT size detection 4
TRAY3_WIDTH
Tray 3 guide plate position
TRAY3_AD
Tray 3 width detection volume output AD value
Tray3 width 
size
(Tray 3 width direction detection size is 
displayed.) A4/A3, 11X, B5/B4, 8.5X, A4R, B5R, 
A5R, 5.5X, 7.25X, EXTRA
40-12
Purpose
Adjustment/Setup
Function
(Purpose)
Used to check the multi-purpose tray width detection 
adjustment value.
Section
Paper feed
Item
Operation
SIMULATION 40-11
TRAY3 SENSOR CHECK..
M1SS1
     M1SS2     M1SS3     M1SS4
TRAY3_WIDTH: 
2100
        TRAY3_AD: 
600
(Tray3 width size: 
A4/A3
)
Press [START] key.
Press [CUSTOM SETTINGS] key.
41
41-1
Purpose
Operation test/Check
Function
(Purpose)
Used to check the operation of the document size 
sensor and the related circuit. (The operation of the 
document size sensor can be monitored with the LCD 
display.)
Section
Other
Item
Operation
OCSW
Document cover 
status
Open: Normal display
Close: Highlighted
PD1 - 7
Document detection 
sensor status
No document: Normal display
Document present: Highlighted
41-2
Purpose
Adjustment
Function
(Purpose)
Used to adjust the document size sensor sensing level.
Section
Other
Item
Operation
SIMULATION 40-12
TRAY3 ADJUSTMENT. SELECT 1-2, AND PRESS START.
1. MAX. POSITION
2. MIN. POSITION
1
SIMULATION 40-12
TRAY3 ADJUSTMENT.
MAX. POSITION ··· COMPLETE (or "ERROR")
Press [CUSTOM SETTINGS] key.
Select 1 and press [START] key. 
SIMULATION 40-12
TRAY3 ADJUSTMENT.
MIN. POSITION ··· COMPLETE (or "ERROR")
SIMULATION 41-1
PD SENSOR CHECK..
OCSW  
PD1
  
PD2
  
PD3
  PD4  PD5  PD6  PD7
AR-M550/M620  SIMULATION  8 - 48
Operation/Procedure
The detection output level (A/D value) of the document sensors (PD1 -
PD7) is displayed in real time.
The value in [ ] on the side of each sensor name indicates the
threshold value.
The light receiving value (A/D value) and the threshold value (A/D
value) of PD1 - PD7 are in the range of 1 - 255. The default of thresh-
old value is 128.
Operation/Procedure
1) Select the number corresponding to the setting mode with 10-key.
2) Press [START] key.
3) Press [CUSTOM SETTINGS] key.
4) Press [START] key.
Operation/Procedure
1) Select the number corresponding to the adjustment item with 10-
key.
2) Press [START] key.
3) Enter the setting (adjustment) value with 10-key.
4) Press [START] key.
Unless special measures are required, do not change the setting val-
ues below.
Select 2 and press [START] key. 
(Error)
Press [CUSTOM SETTINGS] 
key.
41-3
Purpose
Operation test/Check
Function
(Purpose)
Used to check the operation of the document size 
sensor and the related circuit. (The document size 
sensor output level can be monitored with the LCD 
display.)
Section
Other
Item
Operation
OCSW
Original cover status
Open: Normal display
Close: Highlighted
PD1 - 7
PD sensor detection level The value in [ ] indicates the 
adjustment threshold value (SIM41-2 adjustment value).
43
43-1
Purpose
Setting
Function
(Purpose)
Used to set the fusing temperature in each operation 
mode.
Section
Fixing (Fusing)
Item
Operation
SIMULATION 41-2
PD SENSOR ADJUSTMENT. SELECT1-2, AND PRESS START.
(PLEASE OPEN THE ORIGINAL COVER.) 
1. NO ORIGINAL
2. A3 ORIGINAL
1
SIMULATION 41-2
Press [CUSTOM SETTINGS] key. 
Select 1 and 
press [START] key. 
PD SENSOR ADJUSTMENT.
NO ORIGINAL ··· COMPLETE (or "ERROR at 
PD1 PD2
...")
A3 ORIGINAL ··· INCOMPLETE
SIMULATION 41-2
PD SENSOR ADJUSTMENT.
NO ORIGINAL ··· COMPLETE
A3 ORIGINAL ··· COMPLETE (or "ERROR at 
PD1 PD2
...")
SIMULATION 41-3
PD SENSOR DATA DISPLAY.
OCSW
PD1[128]: 200     PD2[128]: 200
PD3[128]:  50     PD4[128]:  52
PD5[128]:  51     PD6[128]:  50
PD7[128]:  52
Item
Japan
Inch 
series
AB 
series
1
INSIDE 
NORMAL
Fusing roller inside/
normal mode
185
200
205
2
OUTSIDE 
NORMAL
Fusing roller outside/
normal mode
185
200
205
3
INSIDE 
PREHEAT
Fusing roller inside/
preheat mode
140
170
170
4
OUTSIDE 
PREHEAT
Fusing roller outside/
preheat mode
140
170
170
5
LEFT 
NORMAL
Sub-heat roller/
normal mode
185
200
205
6
LEFT 
PREHEAT
Sub-heat roller/
preheat mode
140
170
170
Press [START] key.
Press [CUSTOM SETTINGS] key.
43-3
Purpose
Setting (Adjustment)
Function
(Purpose)
Fusing roller RPM setting.
Section
Fixing (Fusing)
Item
Operation
Item
Set range
Default
1
NORMAL
0 – 99
36
2
SLOWDOWN
0 – 99
50
Press [START] key.
Press [CUSTOM SETTINGS] key.
SIMULATION 43-1
1
FUSER TEMPERATURE SET. SELECT 1-6, AND PRESS START.
1. INSIDE NORMAL 
200
   5. LEFT NORMAL 
200
2. OUTSIDE NORMAL 
200
  6. LEFT PREHEAT 
170
3. INSIDE PREHEAT 
170
4. OUTSIDE PREHEAT 
170
SIMULATION 43-1
FUSER TEMPERATURE SET. INPUT VALUE, AND PRESS START.
1. INSIDE NORMAL
200
SIMULATION 43-3
1
FUSER MOTOR SPEED SETTING. SELECT 1-2, AND PRESS 
START.
1. NORMAL   
36
2. SLOWDOWN 
50
SIMULATION 43-3
FUSER MOTOR SPEED SETTING. INPUT VALUE, AND PRESS 
START.
1. NORMAL
36
AR-M550/M620  SIMULATION  8 - 49
Operation/Procedure
1) Each bit (8 kinds) is assigned to each correction item to set
ENABLE/DISABLE of the operation. Different values of 1 - 64 are
assigned to each bit. Enter the total of the values of the bits to be
ENABLED with 10-key.
2) Press [START] key.
NOTE: Set to 223.
When bit=1, correction is made.
NOTE: BIT0 is not displayed, but set to the developing bias correction
function.
This setting is forcibly made enable, and cannot be disabled.
Operation/Procedure
Press [START] key, and the adjustment is automatically performed.
When the adjustment is completed, the adjustment result is displayed.
If the adjustment is not completed normally, "ERROR" is displayed.
When an error occurs, the adjustment result is not revised.
Operation/Procedure
1) Enter the target density level in the image density correction with
10-key.
2) Press [START] key.
44
44-1
Purpose
Setting
Function
(Purpose)
Used to set enable/disable of correction operations in 
the image forming (process) section.
Section
Image process (Photoconductor/Developing/Transfer/
Cleaning)
Item
Operation
Item
Default
BIT1
OPC drum membrane 
decrease (sensitivity/
potential) correction
Laser power/main 
charger grid voltage
1
BIT2
The range of the toner 
patch making voltage in 
the developing bias 
voltage/main charger 
grid voltage correction is 
specified. (Voltage limit)
Developing bias/main 
grid voltage (adjusted by 
SIM 8-1 and 8-2) ±100v
1
BIT3
For humidity correction
Toner concentration 
correction
1
BIT4
Toner concentration 
correction
When the developing 
bias/main charger grid 
voltage correction is 
changed more than the 
specified level, the toner 
concentration control 
level is corrected. 
1
BIT5
Toner concentration 
correction B
Correction for the 
developer life
0
BIT6
Toner concentration 
correction C
Toner concentration 
correction in low density 
image continuous print
1
BIT7
OPC drum for 
environment correction
1
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
Env
Tcon_C
Tcon_B
Tcon_A
Humidity
Pcon_lm
Drum
44-2
Purpose
Adjustment
Function
(Purpose)
Used to perform the gain adjustment (image density 
sensor LED current adjustment) of the image density 
sensor and the gain adjustment (OPC drum marking 
sensor LED current adjustment) of the OPC drum 
marking sensor. 
Section
Image process (Photoconductor)
Item
Operation
SIMULATION 44-1
PROCESS CORRECTION VALUE SETTING. INPUT VALUE 0-999
AND PRESS START.
BIT1: DRUM
BIT2: PROCON_LM   BIT3: HUMIDITY
BIT4: TONERCON_A  BIT5: TONERCON_B
BIT6: TONERCON_C  BIT7: ENVIRONMENT
223
DMLED
Drum marking sensor gain adjustment
PCLED
Image density sensor gain adjustment value
DRUM
Kind of the drum
0 = Other
1 = SHARP drum 
The gain adjustment is completed.
Press [CUSTOM SETTINGS] key.
44-4
Purpose
Setting
Function
(Purpose)
Used to set the target density level in the image 
density correction.
Section
Image process (Photoconductor/Developing)
Item
Operation
Press [START] key.
Press [CUSTOM SETTINGS] key.
44-5
Purpose
Setting
Function
(Purpose)
Used to set the reference developing bias voltage, the 
reference main charger grid voltage, and the laser 
power in the image density correction.
Section
Image process (Photoconductor/Developing)
Item
Operation
SIMULATION 44-2
PROCON GAIN ADJUSTMENT. PRESS START.
DMLED: 
0
PCLED: 
0
DRUM : 
0
SIMULATION 44-2
PROCON GAIN ADJUSTMENT. EXECUTING...
DMLED
0
PCLED
0
DRUM 
1
Press [START] key.
SIMULATION 44-2
PROCON GAIN ADJUSTMENT. COMPLETE.
DMLED:
0
PCLED: 
0
DRUM :
1
SIMULATION 44-4
1
PROCON INITIAL DENSITY SETUP. PRESS START.
1.PROCON INI DENSITY 
32
SIMULATION 44-4
PROCON INITIAL DENSITY SETUP. INPUT VALUE 0-255, AND
PRESS START.
1.PROCON INI DENSITY
32
Page of 98
Display

Click on the first or last page to see other AR-M550 (serv.man15) service manuals if exist.