AR-M351U/M451U, AR-M355U/M455U  ADJUSTMENTS  8 - 7
<Specification>
<3> SPF scan distortion adjustment
Items which must have been completed before this adjust-
ment.
• Adjustment on the engine side (If there is no problem in self
print, no need to adjust.)
• OC scan distortion adjustment
• SPF height adjustment
Items which must be executed after completion of this adjust-
ment.
• SPF off-center
• SPF lead edge adjustment
• Front/rear and left/right void amount setting
1) Make a test chart as shown below. (Print a self-print pattern
71.)
2) Make a copy with DSPF.
3) Check that it is in the specified range.
4) Execute SIM51-2 to check the SPF set value.
Change the set value of the SPF resist amount to the following
value.
5) Though the SPF resist amount is the above value, if there is
any distortion in SPF scan, adjust the SPF installing position in
the following procedures.
6) Loosen the nut which is fixing the adjustment set screw of the
hinge R, and adjust the adjustment set screw.
7) Make a copy again, and check again that the value is in the
specified range.
8) Tighten the nut to fix the adjustment screw.
<Specification>
After the SPF distortion adjustment, perform SIM53-8 SPF
scanning position automatic adjustment.
<4> OC scan magnification ratio adjustment
Items which must have been completed before this adjust-
ment.
• Adjustment on the engine side (If there is no problem in self
print, no need to adjust.)
• OC scan distortion adjustment
Items which must be executed after completion of this adjust-
ment.
• OC scan lead edge adjustment
• Original off-center adjustment
1) Place a print of self-print pattern (A3 or WLT) 70 or a scale on
the table glass.
2) Close the original cover, and make a copy.
3) Check that the value is within the specification.
4) If the value is not within the specified range, execute SIM48-1
(item 3, 4).
5) Make a copy again and check again that the value is within the
specification.
Specification
Adjustment 
position
Distance between 
dove (Reference 
plate) and table 
glass
3-point contact
(Left front/Left rear/Right 
front when viewed from 
the front)
Hinge 
adjustment set 
screw
a
b
a
b
a
b
7
SPF (HIGH)
60
8
SPF (LOW)
75
Specification
Adjustment position
Skew feed
Within ±3mm
Hinge R adjustment screw
1
SIMULATION 51-2
RESIST TIMING ADJUSTMENT. SELECT 0-8, AND PRESS START.
0.TRAY SELECT 
1
  1.PRINT START
2.TRAY1 
60
      3.TRAY2 
50
  4.DESK 
50
5.BPT   
55
      6.ADU   
50
 
7.SPF(HIGH) 
60
  8.SPF(LOW) 
75
a
b
a
b
AR-M351U/M451U, AR-M355U/M455U  ADJUSTMENTS  8 - 8
 
<Specification>
<5> SPF scan magnification ratio
Items which must have been completed before this adjust-
ment.
• Adjustment on the engine side (If there is no problem in self
print, no need to adjust.)
• OC scan distortion adjustment
• SPF scan distortion adjustment
• OC scan magnification ratio
• SPF height adjustment
Items which must be executed after completion of this adjust-
ment.
• SPF scan lead edge adjustment
• Original off-center adjustment
1) Set a chart of print pattern 70 on SPF/DSPF.
2) Make a copy. (In the case of DSPF back copy, make a single
copy in the duplex mode.)
3) Check that the output paper satisfies the specifications. 
4) If the value is not within the specified range, execute SIM48-1
(item 5, 6).
5) Make a copy again, and check that the output paper satisfies
the specifications.
<Specifications>
The SPF main scan direction magnification ratio is common with
OC.
Specification
Adjustment 
position
Adjustment 
value
Main scan direction 
magnification ratio 
CCD (MAIN)
±0.5%
SIM48-1 
(3, 4)
Set value 1: 
0.1% change
Sub scan direction 
magnification ratio 
CCD (SUB)
2
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. SELECT 0-7, AND PRESS START.
0.TRAY SELECT 
1
 1.PRINT START
2.MAGNIFICATION 
100
3.CCD(MAIN) 
50
 4.CCD(SUB) 
50
5.SPF(MAIN) 
50
 6.SPF(SUB) 
50
 7.CIS(MAIN) 
50
Select 2, and 
press [START] key.
Press [START] key, or 
press [CUSTOM SETTINGS] key.
Specifications
Adjustment 
position
Adjustment 
value
SPF sub scan direction 
magnification ratio 
SPF (SUB)
±0.5%
SIM 48-1 
(5, 6)
Set value 1: 
0.1% change
DSPF main scan 
(back) direction 
magnification ratio 
CIS (MAIN)
50
1
2
Select other than 0 - 2, 
and press [START] key.
Press [CUSTOM SETTINGS] key.
Press [START] key. 
Press [CUSTOM SETTINGS] key, 
or terminate copying.
Press [START] key, or 
press [CUSTOM SETTINGS] key.
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. SELECT 0-7, AND PRESS START.
0.TRAY SELECT 
1
 1.PRINT START
2.MAGNIFICATION 
100
3.CCD(MAIN) 
50
 4.CCD(SUB) 
50
5.SPF(MAIN) 
50
 6.SPF(SUB) 
50
 7.CIS(MAIN) 
50
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. INPUT VALUE 0-99, AND PRESS
START.
4.CCD(SUB)
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. NOW COPYING.
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. SELECT 1-15, AND PRESS START.
(FEED TRAY)
   1.TRAY1 2.TRAY2 3.TRAY3 4.TRAY4
   5.BPT   6.LCC
   (ABOVE+10: DUPLEX MODE)
Select 1, and 
press [START] key. 
Select 0, and press [START] key.
100
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT.
(MAGNIFICATION)
  INPUT 25-400(%)
AR-M351U/M451U, AR-M355U/M455U  ADJUSTMENTS  8 - 9
<6> OC scan lead edge adjustment
Items which must have been completed before this adjust-
ment.
• Adjustment on the engine side (If there is no problem in self
print, no need to adjust.)
• OC scan distortion adjustment
• SPF scan distortion adjustment
• OC scan magnification ratio adjustment
Items which must be executed after completion of this adjust-
ment.
• SPF scan lead edge adjustment
• Original off-center adjustment
1) Set an original on the original table. 
2) Enter SIM 50-1.
3) Make a copy. 
4) Select the number to be set on the right of the LCD, and per-
form the adjustment of each item.
5) Select "4: RRC-B" so that the distance between the paper lead
edge and the copy image lead edge is within 4.0mm. Change
the value with 10-key and perform the copy adjustment. 
6) Select "5: DEN-B" so that the white spot in the latter half of
copy (rear edge void) is within 4.0mm. Change the value with
10-key and perform the copy adjustment. 
(The rear void adjustment is changed by the step of 0.1mm.)
• When the rear edge void is too small, increase the value.
• When the rear edge void is too great, decrease the value.
7) Select "3: RRC-A," change the value with 10-key, and adjust
the document scan start position.
8) Press [CA] key to cancel the simulation.
<Specification>
<7> SPF scan lead edge adjustment
Items which must have been completed before this adjust-
ment.
• Adjustment on the engine side (If there is no problem in self
print, no need to adjust.)
• SPF scan distortion adjustment
• SPF scan lead edge adjustment
• SPF magnification ratio adjustment
Items which must be executed after completion of this adjust-
ment.
• SPF/DSPF off-center adjustment
1) Make a copy of a chart which indicates the image loss amount
of each side with SPF/DSPF.
2) Execute SIM50-6 and change the values.
<Set values 1>
Item
Content
Specification
Set 
range
Default
(Lead edge adjustment value)
3 RRCA
Document scan 
start position
4.0mm or 
less
0 - 99
50
Set value 
1: 0.1mm 
shift
4 RRCB
Resist roller 
clutch ON timing 
adjustment value
4.0mm or 
less
10 SIDE2 ADJ.
Correction value 
for RRCB when 
refereeing from 
ADU
1 - 99
50
(Image loss set value)
5 LEAD
Lead edge image 
loss set value
0 - 99
15
Set value 
1: 0.1mm 
shift
6 SIDE
Side image loss 
set value
20
(Void set value)
7 LEAD_EDGE 
(DENA) 
Lead edge void 
set value
Total 8mm 
or less
0 - 99
35
Set value 
1: 0.1mm 
shift
8 TRAIL_EDGE 
(DENB) 
Rear edge void 
adjustment value
Total 8mm 
or less
9 FRONT/
REAR
Front/Rear void 
adjustment value
Total 8mm 
or less
32
2
SIMULATION 50-1
LEAD EDGE ADJUSTMENT. SELECT 0-9, AND PRESS START.
0.TRAY SELECT 
1
   1.COPY START
2.MAGNIFICATION 
100
(ADJUSTMENT DATA) 3.RRCA 
50
   4.RRCB 
50 
10.SIDE2 ADJ. 
50
(IMAGE LOSS SETTING) 5.LEAD 
15
 6.SIDE 
20
(VOID SETTING) 7.LEAD_EDGE(DENA) 
35
               8.TRAIL_EDGE(DENB)
35
  9.FRONT/REAR 
32
Item
Set 
range
Default
0
TRAY SELECT
Paper feed tray 
selection
1 - 6
1
COPY START
Copy START (Default)
2
MAGNIFICATION Print magnification ratio
25 - 
200%
(Lead edge adjustment value)
3
SIDE1
Front surface document 
scan start position 
adjustment value
0 - 99
50
4
SIDE2
Back surface document 
scan start position 
adjustment value
(Image loss set value: SIDE 1)
5
LEAD_EDGE
Front surface lead edge 
image loss set value
0 - 99
15
6
FRONT_REAR
Front surface side edge 
image loss set value
20
7
TRAIL_EDGE
Front surface rear edge 
image loss set value
0 - 20
0
(Image loss set value: SIDE 2)
8
LEAD_EDGE
Back surface lead edge 
image loss set value
0 - 99
15
9
FRONT/REAR
Back surface side edge 
image loss set value
20
10 TRAIL_EDGE
Back surface rear edge 
image loss set value
0 - 20
0
*: For output, select the right side tray.
<Document>
Document set reference
Output result
Rear edge void
Lead edge void
Adjust 
with 
RRCB.
Adjust
with
RRCA.
Image loss
(SIDE)
FR void
Image loss
(LEAD)
Paper transport direction
2
SIMULATION 50-6
LEAD EDGE ADJUSTMENT(SPF). SELECT 0-10, AND PRESS
START.
0.TRAY SELECT 
1
   1.COPY START
2.MAGNIFICATION 
100
(ADJUSTMENT DATA)3.SIDE1 
50
 4.SIDE2 
50
(IMAGE LOSS SETTING)
SIDE1: 5.LEAD_EDGE 
15
 6.FRONT/REAR 
20
  7.TRAIL_EDGE 
0
SIDE2: 8.LEAD_EDGE 
15
 9.FRONT/REAR 
20
 10.TRAIL_EDGE 
0
AR-M351U/M451U, AR-M355U/M455U  ADJUSTMENTS  8 - 10
<Display values 1>
<Set values 2>
With the above + 10, the SPF enters the duplex mode (DD),
making duplex copy.
<Set values 3>
<8> Original off-center adjustment
Items which must have been completed before this adjust-
ment.
• Adjustment on the engine side (If there is no problem in self
print, no need to adjust.)
• OC scan distortion adjustment
• SPF scan distortion adjustment
• OC scan magnification ratio
• SPF scan lead edge adjustment
Items which must be executed after completion of this adjust-
ment.
• Nothing special
1) Set an original on the original table. 
2) Execute SIM 50-12.
3) Select the paper feed tray and the magnification ratio. 
4) After entering the adjustment value, pres START key, and
printing is started.
5) Check the off-center (distance from the paper lead edge) of
the printed copy. Repeat procedure 2 until the printed copy
satisfies the specifications.
• For the duplex mode (Single 
 Duplex), add 10 to the above set
value.
• When the print line is shifted toward a from the paper center,
decrease the value.
• When the print line is shifted toward b from the paper center,
increase the value.
<Specifications>
3. Scanner section
A. OC scan distortion adjustment 
(MB-B rail height adjustment)
• This adjustment requires a high-level preciseness.
It is easier to perform the scanner unit distortion adjustment pre-
viously described. 
Before performing this adjustment, the following adjustment must
have been completed.
• LSU right angle adjustment
1) Make a test chart as shown below. (Print a self-print pattern
71.)
2) Make a copy from the table glass, and check it. 
At that time, set the test chart correctly. If it is set in a distorted
position, the adjustment cannot be made correctly.
3) If the output value is not in the specified range, perform the fol-
lowing adjustment.
4) Remove the front cabinet in front of the scanner, and check
that installing position of the MB rail. 
5) Loosen the screw at the right of the MB rail to adjust.
<Specifications>
Normal display
NOW COPYING
ERROR display
Door open
DOOR OPEN.
Jam
JAM
Paper empty
PAPER EMPTY.
1
TRAY1
2
TRAY2
3
TRAY3
4
TRAY4
5
Manual feed
Set range
25 - 200%
Adjustment position
Measurem
ent 
reference
Specification
Set value
Default
Range
Original 
off-center 
SIM50-12
PLATEN
OC mode
Copy 
output 
center line
As shone in 
the table 
below.
50
0 – 99 Set value 
1: 0.1mm 
shift
SPF 
SIDE1
SPF front 
surface 
adjustment
SPF 
SIDE2
SPF back 
surface 
adjustment
a
b
Specification ± 1.5mm 
Print lead edge
2
SIMULATION 50-12
ORIGINAL OFF-CENTER ADJUSTMENT. SELECT 0-9, AND PRESS
START.
0.TRAY SELECT 
1
   1.COPY START
2.MAGNIFICATION 
100
(ADJUSTMENT DATA)
3.PLATEN 
50
 4.SPF SIDE1 
50
 5.SPF SIDE2 
50
Machine (OC mode)
Single
±1.5mm
Duplex
±1.7mm
Overall (DSPF)
Single S - S
±2.8mm
Single D - S
±3.5mm
Duplex S - D
±3.0mm
Duplex D - D
±3.5mm
Measurement 
point
Specification
Set value
OC scan 
distortion 
adjustment
Angle 
θ
 in the 
above figure
θ
 = 90°±0.13° 1 scale = about 
0.25°shift in 
θ
Page of 17
Display

Click on the first or last page to see other AR-M351U / AR-M451U (serv.man16) service manuals if exist.