Sharp AR-M351U / AR-M451U (serv.man16) Service Manual ▷ View online

AR-M351U/M451U, AR-M355U/M455U  ADJUSTMENTS  8 - 5
When the set value is increased, the warp amount of paper is
increased. When the adjustment value is decreased, the warp
amount of paper is decreased.
<4> Self print lead edge adjustment
Items which must have been completed before this adjust-
ment.
• LSU right angle adjustment (If there is no distortion in self print,
the adjustment is not required.)
• Print off-center adjustment
• Resist amount adjustment
Items which must be executed after completion of this adjust-
ment.
• Front/rear and left/right void amount setting
• OC scan lead edge adjustment
• SPF scan lead edge adjustment
1) Execute SIM 50-5.
2) Set the lead edge void adjustment value (DENA) as specified
below.
(Standard set value) Paper lead edge void: 3.5mm (DENA:
35)
Set the adjustment value of DENA to 35. (Enter 35 as the
adjustment value of DENA, and press [P] key.)
3) Check the lead edge void area on the self print pattern
(SIM67-1).
(Enter 1 and press [START] key.)
4) If the adjustment result is not satisfactory, perform the follow-
ing procedures.
If the lead edge void area is not 3.5mm:
Change the adjustment value of RRCB and perform the
adjustment. (Change the adjustment value of RRCB and
press [START] key.)
(Shift for the adjustment value change: 0.1mm/step)
<Specification>
<5> Front/rear and left/right void amount setting
Items which must have been completed before this adjust-
ment.
• LSU right angle adjustment (If there is no distortion in self print,
the adjustment is not required.)
• Print off-center adjustment
• Resist amount adjustment
• Print lead edge adjustment
Items which must be executed after completion of this adjust-
ment.
• OC scan lead edge adjustment
• SPF scan lead edge adjustment
1) Execute SIM 50-1.
(Lead edge image loss/void area adjustment)
1) Set the lead edge image loss adjustment value (LEAD EDGE)
and the paper lead edge void adjustment value (DENA) as fol-
lows. 
(Standard set value) 
Lead edge image loss: 1.5mm (LEDA: 15)
Paper lead edge void: 3.5mm (DENA: 35)
Set LEAD to 15. (Enter 15 as the adjustment value of LEAD,
and press [P] key.) (0.1mm/step)
Set DENA to 35. (Enter 35 as the adjustment value of
DENA, and press [P] key.) (0.1mm/step)
2) Make a copy at the normal ratio (100%) and check the lead
edge void area and the image loss. (Enter 100 as the set value
of the copy magnification ratio (MAGNIFICATION), and press
[START] key.)
3) If the adjustment result is not satisfactory, perform the follow-
ing procedures.
If the lead edge void are is not 3.5mm:
Change the adjustment value of RRCB and perform the
adjustment. (Change the adjustment value of RRCB and
press [START] key.) (1msec/step)
If the lead edge image loss is not 1.5mm:
Change the adjustment value of RRCA and perform the
adjustment. (Change the adjustment value of RRCA and
press [START] key.)
(Shift for the adjustment value change: 0.2mm/step)
(Rear edge void area adjustment)
Adjust so that the rear edge void area is 3.5mm. (Change the
adjustment value of TRAIL EDGE, and press [START] key.)
(Front/rear frame direction image loss adjustment)
Set the adjustment value of SIDE to 20. (Enter 20 as the adjust-
ment value of SIDE, and press [P] key.)
When the adjustment value is changed, the image position is
shifted in the front/rear frame direction.
(Front/rear frame direction void area adjustment)
Adjust so that the total of the front/rear direction void areas is
7.0mm. (Change the adjustment values of FRONT/REAR, and
press [START] key.)
Front frame void area = 3.5mm
Rear frame void area = 3.5mm
If, as shown above, the front and the rear void areas are not even,
use SIM 50-5 to adjust the image off-center position.
Item
Set 
range
Default
AR-M351U/
M355U
AR-M451U/
M455U
2 TRAY1
Tray 1 resist 
adjustment value
0 - 99
65
60
3 TRAY2
Tray 2 resist 
adjustment value
55
50
4 DESK
Desk resist 
adjustment value
55
50
5 BPT
Manual tray resist 
adjustment value
60
55
6 ADU
ADU resist 
adjustment value
55
50
Set position 
Specification 
Set value
Self print lead 
edge 
adjustment  
SIM 50-5
Print start 
position A of 
the output 
pattern 1
A = 4.0mm or less
(Lead and tail 
total: 8.0mm or 
less)
Shift of 
0.175mm 
(35ppm) / 
0.225mm 
(45ppm) for 
set value 1.
2
SIMULATION 50-5
LEAD EDGE ADJUSTMENT. SELECT 0-20, AND PRESS START.
0.TRAY SELECT 
1
  1.PRINT START
(ADJUSTMENT DATA)
LEAD EDGE: 2.RRCB 
50
    3.SIDE2 ADJ. 
50
RESIST:  4.T1  
50
  5.T2  
50
  6.DESK 
50
         7.BPT 
50
  8.ADU 
50
OFF CENTER: 9.T1   
50
  10.T2  
50
  11.T3 
50
  12.T4 
50
            13.BPT 
50
  14.ADU 
50
(VOID SETTING) 15.LEAD_EDGE(DENA)  
50
               16.TRAIL_EDGE(DENB) 
30
  17.FRONT/REAR 
30
A
[Output pattern]
AR-M351U/M451U, AR-M355U/M455U  ADJUSTMENTS  8 - 6
<Specification>
B. Adjustment on the scanner side
<1> OC scan distortion adjustment
Items which must have been completed before this adjust-
ment.
• Adjustment on the engine side (If there is no problem in self
print, no need to adjust.)
Items which must be executed after completion of this adjust-
ment.
• OC scan off-center
• OC scan lead edge adjustment
1) Make a test chart as shown below. (Make a self-print pattern
71.)
2) Make a copy from the table glass, and check it. 
At that time, set the test chart correctly. If it is set in a distorted
position, the adjustment cannot be made correctly.
3) If the output value is not in the specified range, perform the fol-
lowing adjustment. 
4) Adjust the distortion.
Use a level gauge to check that the scanner is installed hori-
zontally.
Make a copy and check it. If there is any distortion as shown in
Fig. 1 or Fig. 2, loosen the scanner fixing screw (M4 x 8) and
the cam A fixing screw (M3 x 12) and adjust.
• In the case of Fig. 1
Shift cam A in the direction A by the difference in the copy image.
For one scale (one groove), shift by 0.5mm.
After shifting, tighten the fixing screw (M3 x 12) of cam A and
make a copy again, and check the copy again to insure that there
is no distortion. 
• In the case of Fig. 2
Shift cam A in the direction B by the difference in the copy image. 
For one scale (one groove), shift by 0.5mm. 
After shifting, tighten the fixing screw (M3 x 12) of cam A and
make a copy again, and check the copy again to insure that there
is no distortion.
After adjustment, tighten the fixing screw (M3 x 12) and the scan-
ner fixing screw (M4 x 8).
If the above adjustment does not fix the problem, perform the
MB rail adjustment.
After the OC distortion adjustment, perform SIM53-8 SPF scan-
ning position automatic adjustment.
<2> SPF height adjustment
Items which must have been completed before this adjust-
ment.
• Nothing special
Items which must be executed after completion of this adjust-
ment.
• Nothing special
1) Close the (D)SPF.
2) Check to confirm that the dove and the reference plate in the
figure below are in contact with the table glass (point a) and
the side guide (point b). (Place copy paper under the dove and
pull it out.) If they are not in contact, adjust with the set screw.
Set position
Specification
Set 
value
Lead edge void 
adjustment
“LEAD EDGE 
VOID (DENA)”
Output pattern 
“71” print void 
quantity A
A = 4.0mm or 
less
(A and B total: 
8.0mm or less)
Shift of 
0.1mm 
for set 
value 1.
Rear edge void 
adjustment
“TAIL EDGE VOID 
(DENB)”
Output pattern 
“71” print void 
quantity B
B = 4.0mm or 
less
(A and B total: 
8.0mm or less)
Side edge void 
adjustment
“FRONT/REAR”
Output pattern 
“71” print void 
quantity C + D
C and D total: 
8.0mm or less
2
SIMULATION 50-1
LEAD EDGE ADJUSTMENT. SELECT 0-9, AND PRESS START.
0.TRAY SELECT 
1
   1.COPY START
2.MAGNIFICATION 
100
(ADJUSTMENT DATA) 3.RRCA 
50
   4.RRCB 
50 
10.SIDE2 ADJ. 
50
(IMAGE LOSS SETTING) 5.LEAD 
15
 6.SIDE 
20
(VOID SETTING) 7.LEAD_EDGE(DENA) 
50
               8.TRAIL_EDGE(DENB)
30
  9.FRONT/REAR 
30
Print
lead edge
Fixing screw
(M4 x 8)
A
B
[Fig. 1]
[Fig. 2]
First copy image
First copy image
Image
Image
Paper
Paper
Difference
Difference
AR-M351U/M451U, AR-M355U/M455U  ADJUSTMENTS  8 - 7
<Specification>
<3> SPF scan distortion adjustment
Items which must have been completed before this adjust-
ment.
• Adjustment on the engine side (If there is no problem in self
print, no need to adjust.)
• OC scan distortion adjustment
• SPF height adjustment
Items which must be executed after completion of this adjust-
ment.
• SPF off-center
• SPF lead edge adjustment
• Front/rear and left/right void amount setting
1) Make a test chart as shown below. (Print a self-print pattern
71.)
2) Make a copy with DSPF.
3) Check that it is in the specified range.
4) Execute SIM51-2 to check the SPF set value.
Change the set value of the SPF resist amount to the following
value.
5) Though the SPF resist amount is the above value, if there is
any distortion in SPF scan, adjust the SPF installing position in
the following procedures.
6) Loosen the nut which is fixing the adjustment set screw of the
hinge R, and adjust the adjustment set screw.
7) Make a copy again, and check again that the value is in the
specified range.
8) Tighten the nut to fix the adjustment screw.
<Specification>
After the SPF distortion adjustment, perform SIM53-8 SPF
scanning position automatic adjustment.
<4> OC scan magnification ratio adjustment
Items which must have been completed before this adjust-
ment.
• Adjustment on the engine side (If there is no problem in self
print, no need to adjust.)
• OC scan distortion adjustment
Items which must be executed after completion of this adjust-
ment.
• OC scan lead edge adjustment
• Original off-center adjustment
1) Place a print of self-print pattern (A3 or WLT) 70 or a scale on
the table glass.
2) Close the original cover, and make a copy.
3) Check that the value is within the specification.
4) If the value is not within the specified range, execute SIM48-1
(item 3, 4).
5) Make a copy again and check again that the value is within the
specification.
Specification
Adjustment 
position
Distance between 
dove (Reference 
plate) and table 
glass
3-point contact
(Left front/Left rear/Right 
front when viewed from 
the front)
Hinge 
adjustment set 
screw
a
b
a
b
a
b
7
SPF (HIGH)
60
8
SPF (LOW)
75
Specification
Adjustment position
Skew feed
Within ±3mm
Hinge R adjustment screw
1
SIMULATION 51-2
RESIST TIMING ADJUSTMENT. SELECT 0-8, AND PRESS START.
0.TRAY SELECT 
1
  1.PRINT START
2.TRAY1 
60
      3.TRAY2 
50
  4.DESK 
50
5.BPT   
55
      6.ADU   
50
 
7.SPF(HIGH) 
60
  8.SPF(LOW) 
75
a
b
a
b
AR-M351U/M451U, AR-M355U/M455U  ADJUSTMENTS  8 - 8
 
<Specification>
<5> SPF scan magnification ratio
Items which must have been completed before this adjust-
ment.
• Adjustment on the engine side (If there is no problem in self
print, no need to adjust.)
• OC scan distortion adjustment
• SPF scan distortion adjustment
• OC scan magnification ratio
• SPF height adjustment
Items which must be executed after completion of this adjust-
ment.
• SPF scan lead edge adjustment
• Original off-center adjustment
1) Set a chart of print pattern 70 on SPF/DSPF.
2) Make a copy. (In the case of DSPF back copy, make a single
copy in the duplex mode.)
3) Check that the output paper satisfies the specifications. 
4) If the value is not within the specified range, execute SIM48-1
(item 5, 6).
5) Make a copy again, and check that the output paper satisfies
the specifications.
<Specifications>
The SPF main scan direction magnification ratio is common with
OC.
Specification
Adjustment 
position
Adjustment 
value
Main scan direction 
magnification ratio 
CCD (MAIN)
±0.5%
SIM48-1 
(3, 4)
Set value 1: 
0.1% change
Sub scan direction 
magnification ratio 
CCD (SUB)
2
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. SELECT 0-7, AND PRESS START.
0.TRAY SELECT 
1
 1.PRINT START
2.MAGNIFICATION 
100
3.CCD(MAIN) 
50
 4.CCD(SUB) 
50
5.SPF(MAIN) 
50
 6.SPF(SUB) 
50
 7.CIS(MAIN) 
50
Select 2, and 
press [START] key.
Press [START] key, or 
press [CUSTOM SETTINGS] key.
Specifications
Adjustment 
position
Adjustment 
value
SPF sub scan direction 
magnification ratio 
SPF (SUB)
±0.5%
SIM 48-1 
(5, 6)
Set value 1: 
0.1% change
DSPF main scan 
(back) direction 
magnification ratio 
CIS (MAIN)
50
1
2
Select other than 0 - 2, 
and press [START] key.
Press [CUSTOM SETTINGS] key.
Press [START] key. 
Press [CUSTOM SETTINGS] key, 
or terminate copying.
Press [START] key, or 
press [CUSTOM SETTINGS] key.
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. SELECT 0-7, AND PRESS START.
0.TRAY SELECT 
1
 1.PRINT START
2.MAGNIFICATION 
100
3.CCD(MAIN) 
50
 4.CCD(SUB) 
50
5.SPF(MAIN) 
50
 6.SPF(SUB) 
50
 7.CIS(MAIN) 
50
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. INPUT VALUE 0-99, AND PRESS
START.
4.CCD(SUB)
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. NOW COPYING.
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. SELECT 1-15, AND PRESS START.
(FEED TRAY)
   1.TRAY1 2.TRAY2 3.TRAY3 4.TRAY4
   5.BPT   6.LCC
   (ABOVE+10: DUPLEX MODE)
Select 1, and 
press [START] key. 
Select 0, and press [START] key.
100
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT.
(MAGNIFICATION)
  INPUT 25-400(%)
Page of 17
Display

Click on the first or last page to see other AR-M351U / AR-M451U (serv.man16) service manuals if exist.