AR-FX12 SIMULATIONS, FAX SOFTWARE SWITCH 6-33
17
6
Not used
0
0
0
7,8 Coding capacity in send/
receive 
(Reflected on DIS/DCS/
DTC)
(Other than V.34)
Used to set coding capacity to transmit to the other party machine in 
a communication of other than V.34.
0
0
0
JBIG/MMR/
MR/MH
0
0
0
18 1-4 Not used
0
0
0
1
1
1
0
0
0
0
0
0
5
PIN code conformity
Used to set whether the dial number display of FAX is limited to 16 
digits or not. When this item is set to "1: Support," the FAX number 
display by the resend key is limited to 16 digits. The display of 
completion of the job status is also limited to 16 digits. 
0
0
0
Not conform
6-8 Not used
0
0
0
0
0
0
1
1
1
19 1-7 Not used
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
8
Machine booting when 
1300Hz is detected in 
the nighttime FAX mode
Used to set whether the machine is booted or not by detection of 
1300Hz signal from the line in the nighttime FAX mode. (This serves 
as the MDMC PWB jumper in Tiger series.)
When this is changed to "Booted," the machine may be booted by 
noises on the line. Check the singles on the line. 
0
0
0
Not booting
20
1
CSI send
Used to set whether CSI send is performed or not. 
The CSI signal includes the sender's number.
0
0
0
Send
2
DIS reception 
confirmation in G3 
transmission
Used to set whether DIS reception is conformed or not in G3 mode 
transmission (valid only in other than V.34). 
This is valid only when communication is made in other than V.34.
0
0
0
0
3,4 Timer setup between 
flag and address 
(V.21-FSK)
Used to set the timer between Flag and address when receiving FSK 
signal in a communication other than V.34.
0
0
0
6sec
0
0
0
5
Not used
0
0
0
6
Countermeasures 
against echo in 
reception
 (CED tone send interval)
Used to set the time interval (sec) from sending CED or ANSam to 
sending FSK signal of DIS.
If either SW20-6 or SW2-7 is YES, disconnection of the line after 
completion of communication is delayed for 1.5sec.
0
0
0
75msec
SW 
No.
Bit 
No.
Item
Switch selection and function
EU
Au
Asia
Initial value
Key 
operator
Bit No.
7
8
JBIG/MMR/MR/MH
0
0
MMR/MR/MH
0
1
MR/MH
1
0
MH
1
1
1: Conform
0: Not conform
1: Booting
0: Not booting
1: CSI signal not send
0: CSI signal send
1: Reception of DIS 
is checked twice.
0: Reception of NSF/DIS is 
checked once, reception 
without NSF is checked 
twice.
Bit No.
3
4
6sec
0
0
15sec
0
1
30sec
1
0
120sec
1
1
1: 500msec
0: 75msec
[06]SIMULATIONS ・ FAXSOFTWARESWITCH.fm  33 ページ  2004年12月15日 水曜日 午後2時21分
AR-FX12 SIMULATIONS, FAX SOFTWARE SWITCH 6-34
20
7
Countermeasures 
against echo in 
transmission 
(Used to set the hold 
time from DIS reception 
to signal sending.)
Used to set the time interval (sec) from DIS reception to DCS signal 
sending. 
This is valid only in the mode other than V.34.
0
0
0
200msec
8
Not used
0
0
0
21 1-3 Setup of call time in auto 
transmission 
(T0 timer setup)
Used to set the time (sec) of calling when the other party does not 
receive the call in automatic transmission. 
The set range is 30 - 75sec in the increment of 15sec by binary input 
of N into "(15sec x N) + 30sec." The set range of N is 0 ~ 7. When set 
to a value outside the set range, the initial value of the destination is 
applied to.  
0
0
0
45sec
Send 
setup
0
0
0
1
1
1
4-7 T1 timer setup
Used to set the time (sec) for connection of line when the other party 
does not respond in FAX communication. 
The set range is 30 - 105sec in the increment of 5sec by binary input 
of N into "(5sec x N) + 30sec." N is set in the range of 0 - 15. T1 timer 
is the timer for the time from recognition of FAX CED or DCS) by the 
other party after connection of line. The ITU-T standard is 35 ± 5sec.
0
0
0
40sec
0
0
0
1
1
1
0
0
0
8
Not used
0
0
0
22 1-4 Not used
0
0
0
0
0
0
0
0
0
0
0
0
5,6 T4 timer setup at auto 
mode 
(+1.5sec for manual)
Used to set the timer up to respond and receive.
Timer for DCS signal to respond and receive.
 For the ITU-T standard, 3sec ± 15%.
0
0
0
3sec
0
0
0
7,8 Not used
0
0
0
0
0
0
23
1
EOL detection timer
Used to set the detection timer (sec) of EOL (End Of Line) in Phase C 
reception of G3 mode.
If an error occurs in EOL detection, it is processed as EOL not 
detected.
0
0
0
13sec
2-6 Not used
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
7,8 RTN send line error rate Used to set the threshold value for judgment of RTN sending in G3 
reception. The threshold value is of STD conversion. The half of this 
value is used for judgment of RTP sending.
When, for example, FINE is received, the threshold value is doubled.
1
1
1
60 lines
0
0
0
24
1
DCS-TCF interval time
Used to set the time interval (sec) from DCS sending to TCF signal 
sending.
The ITU-T standard is 75 ± 20ms.
0
0
0
75msec
SW 
No.
Bit 
No.
Item
Switch selection and function
EU
Au
Asia
Initial value
Key 
operator
1: 500msec
0: 200msec
Bit No.
5
6
3sec
0
0
4sec
0
1
5sec
1
0
6sec
1
1
1: 25sec
0: 13sec
Bit No.
7
8
6 liens
0
0
12 lines
0
1
60 lines
1
0
120 lines
1
1
1: 150msec
0: 75msec
[06]SIMULATIONS ・ FAXSOFTWARESWITCH.fm  34 ページ  2004年12月15日 水曜日 午後2時21分
AR-FX12 SIMULATIONS, FAX SOFTWARE SWITCH 6-35
24
2
EQM judgment 
threshold value 
when confirming TCF 
reception
Used to set whether the threshold value (FTT) is set severely or 
loosely for EQM judgment in confirmation of TCF reception.
If set loosely, TCF is easy to return CFR, but apt to cause an error in 
PIX (Phase C).
0
0
0
Severely
3
Judgment method in 
confirmation of TCF 
reception
Used to set the judgment method of FTT in confirmation of TCF 
reception.
0
0
0
0
4
Not used
0
0
0
5
Simplified ACR function
0
0
0
Function OFF
6
CED signal send
Used to set whether CED signal is sent or not.
Valid only when SW43.1 (V.34 mode function ) is OFF. 
This is because ANSam signal is indispensable in V.34 mode.
0
0
0
Send
7,8 CED signal send time
Used to set the time for CED signal send.
ANSam signal follows SW46-7 ~ 8.
0
0
0
3sec
0
0
0
25 1,2 CED/ANSam send start 
wait time
Used to set the wait time for sending CED/ANSam signals to the line 
from FAX reception state after connection of the line.
0
0
0
2.25sec
0
0
0
3,4 CNG send time
Used to set the wait time from connection of the line to sending of 
CNG signal to the line.
0
0
0*
* Taiwan: 1
0.5sec
2.0sec (Taiwan 
only)
0
0
0*
5
CED detection time
Used to set the wait time for determination of the signal when 
detecting CED/ANSam signal.
0
0
0
500ms
6-8 Not used
0
0
0
0
0
0
0
0
0
26 1,2 Number of times of RCP 
send 
Used to set the number of times of RCP send when sending Phase C 
in ECM system.
When the other party cannot detect the RCP frame, it becomes easy 
to detect RCP.
0
0
0
3  times
0
0
0
SW 
No.
Bit 
No.
Item
Switch selection and function
EU
Au
Asia
Initial value
Key 
operator
1: Loosely
0: Severely
1: Judged by EQM 
value. TCF is 
checked loosely.
0:  Received data is judged to 
be 0 or not, and EQM value 
is judged.
1: Function ON
0: Function OFF
1:CED signal is not sent.
0:CED signal is sent.
Bit No.
7
8
3sec
0
0
4sec
0
1
5sec
1
0
6sec
1
1
Bit No.
1
2
2.25sec
0
0
3sec
0
1
4sec
1
0
2.25sec
1
1
Bit No.
3
4
0.5sec
0
0
1sec
0
1
1.5sec
1
0
2.0sec
1
1
1: 1000ms
0: 500ms
Bit No.
1
2
3 times
0
0
6 times
0
1
9 times
1
0
12 times
1
1
[06]SIMULATIONS ・ FAXSOFTWARESWITCH.fm  35 ページ  2004年12月15日 水曜日 午後2時21分
AR-FX12 SIMULATIONS, FAX SOFTWARE SWITCH 6-36
26
3
Number of RTC EOL 
send
Used to set how many EOL's are sent as RTC when sending Phase 
C.
When the other party cannot detect the RCP, it becomes easy to 
detect RCP.
0
0
0
6  times
4-8 Not used
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
27 1-4 Echo suppressor tone 
setup
Used to set YES/NO of echo suppressor tone in each high-speed 
modulation system.
0
0
0
YES 
(No for V.29 
only)
0
0
0
1
1
1
0
0
0
5-8 Not used
0
0
0
1
1
1
1
1
1
1
1
1
28 1-8 Not used
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
29 1-5 FAX paper exit tray 
setting
Used to specify the default output tray in the combination of each 
output
system. The combinations of the output trays are as follows.
In the case of the main unit only or the main unit without the manual 
feed tray
and with the duplex tray, the output is always made from the center 
tray.
0
0
0
Receive
setup
0
0
0
0
0
0
0
0
0
0
0
0
6-8 Not used
0
0
0
0
0
0
0
0
0
30
1
Not used
0
0
0
2
Error reception in RTN 
reception
Used to set whether RTN signal reception is judged as an error or 
not. (Only in G3 mode)
0
0
0
Judges as an 
error
SW 
No.
Bit 
No.
Item
Switch selection and function
EU
Au
Asia
Initial value
Key 
operator
1: 12 times
0: 6 times
Bit No.
V.33
1
1 : NO
0 : YES
V.17
2
1 : NO
0 : YES
V.29
3
1 : NO
0 : YES
V.27
4
1 : NO
0 : YES
Bit No.
Main unit + Manual Duplex
1
1:CENTER 
TRAY
0:LEFT 
TRAY
Finisher + Duplex / 
Finisher
2
1:FINISHER 
TOP TRAY
0:LEFT 
TRAY
Mail bin stacker + Duplex / 
Mail bin stacker
3
1:MAIL  BIN 
TOP TRAY
0:LEFT 
TRAY
Main unit + Saddle finisher 
+ Duplex 
4
1:CENTER 
TRAY
0:FINISHER 
TRAY
Mail bin stacker + Saddle 
finisher
5
1:MAIL  BIN 
TOP TRAY
0:FINISHER 
TRAY
1: RTN reception is not 
judged as an error.
0: RTN reception is 
judged as an error.
[06]SIMULATIONS ・ FAXSOFTWARESWITCH.fm  36 ページ  2004年12月15日 水曜日 午後2時21分
Page of 108
Display

Click on the first or last page to see other AR-FX12 (serv.man7) service manuals if exist.