S07/Ua01/P14
Upper heater lamp
1) Remove the lamp holders and the connector.
2) Remove the upper heater lamp.
2) Remove the upper heater lamp.
S07/Ua01/P15
Duplex gate solenoid (AR-C150/C250)
1) Open the paper exit/transport guide.
2) Remove the screw and the spring, and remove the duplex gate
solenoid.
S07/Ua01/P16
Heater lamp control PWB (AC sub PWB)
1) Remove the connector, and remove the heater lamp control PWB
(AC sub PWB) (S07/Ua01/P16).
S07/Ua01/P17
Lower separation pawl
1) Open the upper and the lower fusing units.
2) Open the lower separation pawl unit (paper guide).
(AR-C150)
2) Open the lower separation pawl unit (paper guide).
(AR-C150)
(AR-C250/C160/C270)
3) Remove the spring, and remove the lower separation pawl
(S07/Ua01/P17/CHK/REP).
(AR-C150)
S07/Ua01/P15
S01/Ua01/P15
Installing position: Center
S07/Ua01/P17/CHK/REP
11 – 29
(AR-C250/C160/C270)
∗
When installing the lower separation pawl unit (paper guide) in the
AR-C250, observe the following instruction.
Insert thick paper of OHP sheet (A4 or 11"
AR-C250, observe the following instruction.
Insert thick paper of OHP sheet (A4 or 11"
×
8.5" or greater)
between the lower heat roller and the paper exit roller, and install
so that the lower separation pawl is along the paper.
so that the lower separation pawl is along the paper.
S07/Ua01/P18
Lower heater lamp
1) Remove the lamp holders and the connectors.
2) Pull out the lower heat lamp.
2) Pull out the lower heat lamp.
S07/Ua01/P19
Lower heat roller
1) Remove the heater lamps. S07/Ua01/P14 S07/Ua01/P18
2) Open the upper and the lower fusing units.
3) Remove the lower separation pawl unit (paper guide), and remove
3) Remove the lower separation pawl unit (paper guide), and remove
the lower heat roller unit.
(AR-C100/C150)
(AR-C250/C160/C270)
4) Remove the parts, and remove the lower heat roller.
∗
For the AR-C160/C270, replace the whole unit of the lower heat
roller unit.
roller unit.
S07/Ua01/P17/CHK/REP
S07/Ua01/P18
11 – 30
S07/Ua01/P20
Paper entry detector
1) Remove the connector, and remove the paper entry detector
(S07/Ua01/P20).
∗
Clean the detector.
S07/Ua01/P21
Oil pump
Clean and remove oil attached on the external surfaces.
Clean the oil filter attached to the oil pump suction port with waste
cloth.
If the oil filter is clogged, oil is not sufficiently supplied to the heat
roller, causing a trouble.
cloth.
If the oil filter is clogged, oil is not sufficiently supplied to the heat
roller, causing a trouble.
•
When installing (replacing) this pump, set the pump operation
value of Sim 43-7 referring to the marking color shown in the illus-
tration below.
value of Sim 43-7 referring to the marking color shown in the illus-
tration below.
S07/Ua02
Paper exit unit
1) Remove the screw and the connector, and remove the paper exit
unit (S07/Ua02).
S07/Ua02/P01
Paper exit detector
1) Remove the paper exit unit. S07/Ua02
2) Remove the connector, and remove the paper exit detector
(S07/Ua02/P01/CLN).
∗
Clean it.
S07/Ua02/P02
Paper exit roller
S07/Ua02/P03
Gear
S07/Ua02/P04
Paper exit idle roller
1) Remove the paper exit unit. S07/Ua02
2) Remove the screw, and remove the paper exit roller unit.
S07/Ua01/P20/CLN
S06/Ua06/P24
Marking
S07/Ua02/P01/CLN
11 – 31
3) Remove the parts, and remove the paper exit roller
(S07/Ua02/P02/CLN).
∗
Clean with alcohol.
∗
Apply grease to the gear (S07/Ua02/P03/GRE) and the inside
of the paper exit idle roller (S07/Ua02/P04/CLN/GRE).
of the paper exit idle roller (S07/Ua02/P04/CLN/GRE).
S10
PWB
S10/P01
ICU main PWB
S10/P02
ICU image PWB
S10/P03
ICU scan PWB
(AR-C150/C250)
1)
Remove the original cover. S01/P01
2)
Remove the rear cover upper. S01/P02
3)
Remove the glass holder right. S01/P05
4)
Remove the glass holder left. S01/P06
5)
Remove the table glass. S01/P07
6)
Remove the shading glass AS. S01/P08
7)
Remove the operation unit. S02/Ua01
8)
Remove the screw, and remove the dark box cover.
9)
Remove the screw, and remove the flat cable holder.
10) Remove the flat cable from the CCD.
11) Remove the screw, and remove the scanner fixing angle.
12) Remove the screw, and remove the stopper.
13) Open the scanner (reading) unit. Support it with the stopper.
11) Remove the screw, and remove the scanner fixing angle.
12) Remove the screw, and remove the stopper.
13) Open the scanner (reading) unit. Support it with the stopper.
14) Remove the screw, and remove the ICU cover.
15) Remove the ICU main PWB, the ICU image PWB, and the ICU
scan PWB.
S07/Ua02/P02/CLN
S07/Ua02/P04/CLN/GRE
S07/Ua02/P03/GRE
S04/Ua01
11 – 32