DOWNLOAD Sharp AR-C150 (serv.man4) Service Manual ↓ Size: 36.13 MB | Pages: 127 in PDF or view online for FREE

Model
AR-C150 (serv.man4)
Pages
127
Size
36.13 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / ARC150 250-Service Manual
File
ar-c150-sm4.pdf
Date

Sharp AR-C150 (serv.man4) Service Manual ▷ View online

(AR-C150)
SIM No.
Content
Set value
U.S.A.
Canada
Inch
Japan
AB_B
Europe
U.K.
Aus.
AB_A
SIM26-02
Manual feed paper kind display
2
2
2
0
1
1
1
1
1
SIM26-02
LEGAL  set  value
0
0
0
0
0
0
0
1
0
SIM26-28
AC power voltage
120
120
120
100
100
230
230
230
230
SIM26-30
CE mark Enable/Disable
0
0
0
0
0
1
1
1
1
SIM26-52
White paper exit count up 
1
1
1
0
1
1
1
0
1
SIM43-1A
Normal mode control temperature (HL1)
180
180
180
170
170
180
180
180
180
SIM43-1B
Normal mode control temperature (HL2)
135
135
135
125
125
135
135
135
135
SIM43-1C
Ready state control temperature (HL1)
187
187
187
177
177
187
187
187
187
SIM43-1D
Ready state control temperature (HL2)
142
142
142
132
132
142
142
142
142
SIM26-55
Priority to fusing over image quality in color copy
with heavy paper Enable/Disable
1
1
2
2
2
2
2
2
2
(AR-C250)
SIM No.
Content
Set value
U.S.A.
Canada
Inch
Japan
AB_B
Europe
U.K.
Aus.
AB_A
SIM26-02
Manual feed paper kind display
2
2
2
0
1
1
1
1
1
SIM26-02
LEGAL  set  value
0
0
0
0
0
0
0
1
0
SIM26-28
AC power voltage
120
120
120
100
100
230
230
230
230
SIM26-30
CE mark Enable/Disable
0
0
0
0
0
1
1
1
1
SIM26-52
White paper exit count up
1
1
1
0
1
1
1
0
1
SIM26-55
Priority to fusing over image quality in color copy
with heavy paper Enable/Disable
1
1
2
2
2
2
2
2
2
SIM48-6C
Fusing motor speed correction value (L)
40
40
40
50
50
40
40
40
40
SIM48-6D
Fusing motor speed correction value (S)
40
40
40
45
45
40
40
40
40
SIM43-1A
Normal mode (HL1)
170
170
170
170
170
170
170
170
170
SIM43-1B
Normal mode (HL2)
125
125
125
140
140
125
125
125
125
SIM43-1C
Ready state (HL1)
177
177
177
177
177
177
177
177
177
SIM43-1D
Ready state (HL2)
132
132
132
140
140
132
132
132
132
SIM43-1E
Energy-save mode (HL1)
136
136
136
136
136
136
136
136
136
SIM43-1F
Reset from the pre-heat mode (HL1)
148
148
148
148
148
148
148
148
148
SIM43-1I
Heavy paper mode 1
200
200
200
200
200
200
200
200
200
SIM43-1J
Heavy paper mode 2
155
155
155
155
155
155
155
155
155
AR-C100
User logo setting
Select the desired logo and press the [OK] key. (Logo displayed
on the LCD)
Item
Content
Upper
limit
Lower
limit
Default
value
A
User logo setting
10
0
0
Item
Set value
Content
A
0
Without logo
1
Family  mart
2
Sunkus
3
Daily Yamazaki
4
Camel mart
5
Daiwa
6
Poplar
7 –  10
Without logo
8 –  14
(AR-C160/C270)
SIM No.
Content
Set value
U.S.A
Canada
Inch
Japan
AB_B
Europe
U.K.
Aus.
AB_A
SIM26-02 Manual feed paper kind display
2
2
2
0
1
1
1
1
1
SIM26-02 LEGAL  set  value
0
0
0
0
0
0
0
P
O
SIM26-28 AC power voltage
120
120
120
100
100
230
230
230
230
SIM26-30 CE mark Enable/Disable
0
0
0
0
0
1
1
1
1
SIM26-52 White paper exit count up
1
1
1
0
1
1
1
O
1
SIM26-55 Thick paper image process
mode setup
DISABLE
DISABLE
DISABLE
DISABLE
DISABLE
DISABLE DISABLE DISABLE
DISABLE
SIM43-1A Normal mode control
temperature (HL1)
170
170
170
170
170
170
170
170
170
SIM43-1B Normal mode control
temperature (HL2)
125
125
125
125
125
125
125
125
125
SIM43-1C Ready state control
temperature (HL1)
177
177
177
177
177
177
177
177
177
SIM43-1D Ready state control
temperature (HL2)
132
132
132
132
132
132
132
132
132
SIM43-1E Control temperature in the
energy-save mode (HL1)
146
146
146
146
146
146
146
146
146
SIM43-1F Control temperature when
resetting from pre-heat to
monochrome (HL1)
158
158
158
158
158
158
158
158
158
SIM43-1I
Control temperature in the
thick mode 2 (HL1)
200
200
200
200
200
200
200
200
200
SIM43-1J Control temperature in the
thick mode 2 (HL2)
155
155
155
155
155
155
155
155
155
SIM43-1K OHP mode control
temperature (HL1)
180
180
180
180
180
180
180
180
180
SIM43-1L OHP mode control
temperature (HL2)
175
175
175
175
175
175
175
175
175
SIM48-6C Fusing motor speed correction
adjustment value (L)
50
50
50
55
55
50
50
50
50
SIM48-6D Fusing motor speed correction
adjustment value (S)
55
55
55
60
60
55
55
55
55
26 - 32
Purpose
Setting
Function
(Purpose)
Used to set the fan rotating speed (low speed).
Item
Operation
Operation/
Procedure
1. Select the fan motor whose speed is to be adjusted
with [
] and [
] keys and press the [OK] key.
2. Enter the adjustment value with the 10-key.
3. Press the [OK] key.
The adjustment value entered in procedure 2 is set.
In the fan motor low speed rotation mode (ready condition), the ro-
tating speed is controlled with this adjustment value.
The adjustment value means PWM duty %.
Default value
VFM
: Exhaust fan motor 1
15
VFM (HEAT) : Exhaust fan motor 1 (Pre-heating)
15
CFM1
: Optical cooling fan motor 1
0
LSUFM
: LSU cooling fan motor
15
DCFM
: DC power cooling fan motor
0
(AR-C160/C270)
8 –  15
26 - 55
Purpose
Setting
Function
(Purpose)
Used to set the fusing capability (image process) in the
heavy paper mode. (AR-C150)
Used to select the gamma characteristics in the color
copy mode. (AR-C250/C160/C270)
Item
Operation
Operation/
Procedure
(AR-C150)
Press the ENABLE or the DISABLE key to set.
This simulation is used to give priority to the fusing
capability over the image quality in color copy with
heavy paper.
The quantity of black toner which forms images on the paper is re-
duced in the image process to have better fusing.
It is advisable to use this setting when poor fusing results from
color copy with heavy paper.
When ENABLE (priority to the fusing capability over image quality)
is selected, the black density is slightly reduced to shift the color
phase. Normally set to DISABLE.
Setup
Operation/Effect
Default
ENABLE
K toner is reduced and the black
reproduction is supplemented by
Y/M/C toner in image process./Fusing
capability is increased when heavy
paper is used.
U.S.A./CANADA
DISABLE Normal image process
Except for
U.S.A./CANADA
In some AR-C100/C150 machines with an old ROM version,
this simulation is added from the middle of the production. 
In the AR-C150 machines with an old ROM version, upgrading
of the ROM version allows to perform this simulation.
PCU MAIN PWB
Flash ROM
later than 5.07
OPERATION PWB
Flash ROM
later than 5.05
ICU MAIN PWB
Flash ROM
later than 5.09
(AR-C250/C160/C270)
Press the ENABLE / DISABLE key to select. 
This is used to set the order of priority between sharpness and
gradation in the color copy mode. Setup is made by changing the
gamma in the high density area.
Setup
Operation/Effect
Default
ENABLE The contrast in the color copy
mode is increased. (Priority is
given to sharpness.)
UK (AR-C250)
DISABLE Normal gamma (Priority is
given to gradation.)
Except for UK
(AR-C250) /
(AR-C160) / (AR-C270)
29
29 - 4
Purpose
Setting
Function
(Purpose)
Used to set the print count system in the printer mode.
(AR-C150/C250/C160/C270)
Section
Memory
Item
Counter
Operation/
Procedure
Set whether to count all the pages as color print pages
or to count color pages and monochrome pages sepa-
rately in the printer mode when a print job of mixed
documents of color pages and monochrome pages is
performed.
Item
Set
value
Content
Transfer belt position
Total counter
Maintenance counter
A
0
All the pages are counted by the
color counter.
All the pages are counted
by the color counter.
Color mode
1
Color pages and black-and-white
pages are counted separately.
All the pages are counted
by the color counter.
Color mode
2
Color pages and black-and-white
pages are counted separately.
Color pages and
black-and-white pages
are counted separately.
Every time when the print page is switched to the color
page/black-and-white page, the transfer belt position is switched
to the color/black-and-white mode position accordingly.
3
1
Single
Color pages and
black-and-white pages
are counted separately.
Color pages and
black-and-white pages
are counted separately.
Every time when the print page is switched to the color
page/black-and-white page, the transfer belt position is switched
to the color/black-and-white mode position accordingly.
Duplex
All the pages are counted
by the color counter.
All the pages are counted
by the color counter.
Color mode
4
1
Single
Color pages and
black-and-white pages
are counted separately.
Color pages and
black-and-white pages
are counted separately.
Every time when the print page is switched to the color
page/black-and-white page, the transfer belt position is switched
to the color/black-and-white mode position accordingly.
Duplex
Color pages and
black-and-white pages
are counted separately.
All the pages are counted
by the color counter.
Color mode
1: AR-C250/C270 only
8 –  16
43
43 - 1
Purpose
Setting
Function
(Purpose)
Used to set the fusing temperature in each operation
mode.
Section
Fixing (Fusing)
Item
Operation
Operation/
Procedure
1. Select the kind of lamps and the operation mode
with [
], [
] keys.
2. Enter the set value with the 10-key.
3. Press the [OK] key to set the fusing temperature set in proce-
dure 2.
(AR-C100/C150)
Display
Content
Set
range
Set value
NOTE
U.S.A Canada
Inch
Japan
AB_B
Europe
U.K
Aus.
AB_A
A: HL1 PLAIN
  PAPER
Normal mode control
temperature (HL1)
70 to
200
180
180
180
170
170
180
180
180
180
B: HL2 PLAIN
  PAPER
Normal mode control
temperature (HL2)
70 to
200
135
135
135
125
125
135
135
135
135
C: HL1 READY
Ready state control
temperature (H1)
70 to
200
187
187
187
177
177
187
187
187
187
D: HL2 READY
Ready state control
temperature (H2)
70 to
200
142
142
142
132
132
142
142
142
142
E: HL1 E_STAR
Energy save mode control
temperature (HL1)
70 to
200
140
140
140
140
(137)
140
140
140
140
140
( )
AR-C100
F: HL1 PRE_BK
Control temperature (HL1)
when resetting to B/W
from preheat 
70 to
200
155
155
155
155
(152)
155
155
155
155
155
( )
AR-C100
G: HL1
  HEAVYPAPER
Heavy paper mode control
temperature (HL1)
70 to
200
200
200
200
200
200
200
200
200
200
AR-C150
only
H: HL2
  HEAVYPAPER
Heavy paper mode control
temperature (HL2)
70 to
200
155
155
155
155
155
155
155
155
155
AR-C150
only
I: HL1
  TRANSPARENCY
OHP mode control
temperature (HL1)
70 to
200
180
180
180
180
180
180
180
180
180
AR-C150
only
J: HL2
  TRANSPARENCY
OHP mode control
temperature (HL2)
70 to
200
175
175
175
175
175
175
175
175
175
AR-C150
only
(AR-C250/C160/C270)
Display
Content
Set
range
Set value
NOTE
U.S.A Canada
Inch
Japan AB_B Europe
U.K
Aus.
AB_A
A: HL1 PLAIN
  PAPER
Normal mode control
temperature (HL1)
70 to
200
170
170
170
170
170
170
170
170
170
B: HL2 PLAIN
  PAPER
Normal mode control
temperature (HL2)
70 to
200
125
125
125
140
(125)
140
(125)
125
125
125
125
( )
AR-C160/C270
C: HL1 READY
Ready state control
temperature (H1)
70 to
200
177
177
177
177
177
177
177
177
177
D: HL2 READY
Ready state control
temperature (H2)
70 to
200
132
132
132
140
(132)
140
(132)
132
132
132
132
( )
AR-C160/C270
E: HL1 E_STAR
Energy save mode control
temperature (HL1)
70 to
200
136
(146)
136
(146)
136
(146)
136
(146)
136
(146)
136
(146)
136
(146)
136
(146)
136
(146)
( )
AR-C160/C270
F: HL1 PRE-BK
Control temperature (HL1)
when resetting to B/W
from preheat 
70 to
200
148
(158)
148
(158)
148
(158)
148
(158)
148
(158)
148
(158)
148
(158)
148
(158)
148
(158)
( )
AR-C160/C270
G: HL1
  HEAVYPAPER1
Heavy paper 1 mode
control temperature (HL1)
70 to
210
185
185
185
185
185
185
185
185
185
H: HL2
  HEAVYPAPER1
Heavy paper 1 mode
control temperature (HL2)
70 to
200
155
155
155
155
155
155
155
155
155
I: HL1
  HEAVYPAPER2
Heavy paper 2 mode
control temperature (HL1)
70 to
210
200
200
200
200
200
200
200
200
200
J: HL2
   HEAVYPAPER2
Heavy paper 2 mode
control temperature (HL2)
70 to
200
155
155
155
155
155
155
155
155
155
K: HL1
  TRANSPARENCY
OHP mode control
temperature (HL1)
70 to
200
180
180
180
180
180
180
180
180
180
L: HL2
  TRANSPARENCY
OHP mode control
temperature (HL2)
70 to
200
175
175
175
175
175
175
175
175
175
8 –  17
Page of 127
Display