Check that the following simulation values are in the specified range. If not, set it to the  proper value.
SIM No
ITEM
SPEC
Change in copy quality
due to change in setting
Phenomenon caused
by improper setting
NOTE
Standard value
43-1
HL1 PLAIN PAPER
Default value
(Depending on the
destination. Refer to
Service Manual.)
– 5 / +10
Fusing capability and
image gloss are changed.
Improper fusing,
image deflection,
image flow, image dirt
Check that the
setting is made
according to the
destination. (Refer to
Service Manual.)
Check that the set
values are in the
specified range.
HL2 PLAIN PAPER
– 5 / +10
HL1 READY
– 0 / +0
HL2 READY
– 0 / +0
HL1 E_STAR
– 0 / +0
HL1 PRE-BK
– 0 / +0
HL1 HEAVYPAPER1
– 5 / +10
HL2 HEAVYPAPER1
– 5 / +10
HL1 HEAVYPAPER2
– 5 / +0
HL2 HEAVYPAPER2
– 5 / +0
HL1 TRANSPARENCY
– 5 / +10
HL2 TRANSPARENCY
– 5 / +10
If the copy quality adjustment cannot provide a normal copy quality, check that the following simulation values are in the specified range. If not, set
the values as specified.
SIM No
ITEM
SPEC
Phenomenon caused when the
set value is changed
Phenomenon caused when
the set value is outside the
specified range
NOTE
BLUE RANK
RED RANK
NO-DISPLAY
RANK
43-7
A
12
12
12
When the set value is decreased,
the oil supply is decreased. When
the set value is increased, the oil
supply is increased.
Shortened life due to
damage on the heat roller
surface, degraded image
gloss, abnormal image,
image dirt, improper fusing,
paper jam, oil leakage, oil
dirt
B
80
180
130
When the set value is increased,
the oil supply is decreased. When
the set value is decreased, the oil
supply is increased.
If the copy quality adjustment cannot provide a normal copy quality, check the following parts for any abnormality.
PART NAME
Phenomenon caused by abnormal parts
NOTE
Fusing oil application roller
Shortened life due to damage on the heat roller surface, degraded image gloss,
abnormal image, image dirt, improper fusing, paper jam, oil leakage, oil dirt
In case of an abnormality,
replace the part.
Fusing roller cleaning roller
Fusing application felt
Fusing application blade
Fusing roller
Fusing gear
Greater banding, improper image (color shift, flow, deflection), toner dispersion
Check the following items are properly adjusted. If any adjustment is improper, adjust it properly.
JOB No
WORK ITEM
Trouble caused by improper adjustment
NOTE
ADJ M22 Fusing pressure adjustment Improper fusing, improper image gloss, paper jam,
paper wrinkles
Perform the adjustment in case of improper fusing,
improper image gloss, paper jam, or paper wrinkles.
Check the following items.
WORK ITEM
SPEC
Phenomenon caused by oil filter problem
NOTE
Check the oil pump filter
condition.
Check that the oil pump filter
is not clogged.
Shortened life due to damage on the heat roller
surface, lower image gloss, image abnormality, image
dirt, improper fusing, paper jam, oil leakage, oil dirt
Check and clean the oil filer
at every servicing.
Check that the following simulation values are properly set. If not, set it to the  proper value.
SIM No
ITEM
SPEC/Default value
Phenomenon caused when the value is outside the specified range
NOTE
48-1
B
50
Degraded accuracy of area separation
(degraded accuracy of filter process, black
character and black-line edge process)
Degraded sharpness of
black characters and black
lines, increased moire
Check that the set item B is set
to 50. If it is not set to 50, the
best quality cannot obtained.
7 –  36
Check that the following simulation values are in the specified range. If not, set the values as specified.
SIM No
ITEM
SPEC
Phenomenon
caused when
the set value
is changed
Phenomenon
caused when the
set value is outside
the specified range
NOTE
AR-C100/C150
AR-C250
AR-C160/C270
Default
Standard
value
Default
Standard
value
Default
Standard
value
48-6
RRM
55
±
 
0
55
±
 
0
55
±
 0
Change in the
resist motor
RPM
Improper image at
the rear end in the
paper transport
direction (color shift,
flow, dirt, deflection)
BELTM
51
±
 
0
51
±
 
0
51
±
 0
Change in the
transfer belt
rotation speed
Greater banding,
improper image
(color shift, flow,
deflection, flow),
toner dispersion
FSM(L)
45
Default
+ 20
50 (Japan)
40 (Except
Japan)
Default
+ 20
55 (Japan)
50 (Except
Japan)
Default
+ 20
Change in the
fusing roller
rotation speed
Improper image at
the rear end in the
paper transport
direction (color shift,
flow, dirt, deflection)
FSM(S)
40
Default
+ 20
45 (Japan)
40 (Except
Japan)
Default
+ 20
60 (Japan)
55 (Except
Japan)
Default
+ 20
DM(BK)
42
±
 
0
42
±
 
0
42
±
 0
Change in the
black OPC
drum rotation
speed
Greater banding,
improper image
(color shift, flow,
deflection, flow),
toner dispersion
DM(CL)
37
±
 
0
37
±
 
0
37
±
 0
Change in the
color OPC
drum rotation
speed
Greater banding,
improper image
(color shift, flow,
deflection, flow),
toner dispersion
Check that the following simulation values are in the specified range. If not, set the values as specified.
SIM No
ITEM
SPEC
Phenomenon caused when the value is
not as specified
NOTE
AR-C150
AR-C250/C160/C270
46-6
B
A(OFFSET ODD)
150
150
Improper image
scan level (density,
color balance)
Improper image
density, improper
color balance
Be sure to set as
specified.
B(OFFSET EVEN)
150
150
C(GAIN ODD)
120
150
D(GAIN EVEN)
120
150
G
A(OFFSET ODD)
150
150
B(OFFSET EVEN)
150
150
C(GAIN ODD)
140
130
D(GAIN EVEN)
140
130
R
A(OFFSET ODD)
150
150
B(OFFSET EVEN)
150
150
C(GAIN ODD)
180
160
D(GAIN EVEN)
180
160
Check that the following items are properly set. If any adjustment is improper, adjust it properly.
JOB No
WORK ITEM
NOTE
ADJ M1 DV Doctor gap adjustment
Improper image density, improper copy, improper color balance, toner dispersion, developer
dispersion
ADJ M2 DV roller main pole position adjustment
(Auto color balance adjustment service target gamma setup)
a. Outline
Auto color balance adjustment is performed with a certain color balance (gamma) as a target. There are following two kinds of targets:
Only the service target among them allows optional setup of a color balance (gamma) target.
This setup must be performed in the following cases.
When the user requests to customize the color balance.
When the service target gamma is found to be incorrect.
When the copy color balance and the density adjustment is manually performed. (SIM 46-21)
When a U2 trouble occurs.
When the ICU main PWB is replaced.
When the EEPROM on the ICU main PWB is replaced.
7 –  37
Kinds of color balance (gamma) target
NOTE: The above figure is for a brief description, and does not show
the actual state.
Kinds
Descriptions
A
Default color
balance (gamma)
target (fixed)
This is the average, standard color
balance (gamma) target determined by
the machine design.
This color balance (gamma) target is
identical in all the machines, without
consideration for individuality of machines.
When SIM 63-8 is executed, the service
color balance (gamma) target becomes
the same as this target.
In SIM 46-24 (46-22) menu, this target is
not displayed. 
B
factory  color
balance (gamma)
target (fixed)
This is the standard color balance
(gamma) target which was registered (set)
in the factory, and cannot be changed in
the market.
This color balance (gamma) target is set
depending on individuality of each
machine to obtain the standard color
balance. It, therefore, differs slightly in
different machines. When the service
target falls into an abnormal state by
some reasons, this target can be used
instead of it.
When shipping, this target is the same as
the service color balance (gamma) target. 
C
Service color
balance (gamma)
target (variable)
This is obtained by registering (setting)
with SIM 63-7 the adjustment pattern of
the color balance (gamma) which was
adjusted with SIM 46-21.
This color balance (gamma) target is set
depending on individuality of each
machine to obtain the standard color
balance. It, therefore, differs slightly in
different machines. However, an optional
color balance (gamma) target can be set
according to a user’s request.
When shipping, this target is the same as
the factory color balance (gamma) target.
When SIM 63-8 is executed, the service
color balance (gamma) target becomes
the same as the default color balance
(gamma) target. 
NOTE: Do not execute SIM 63-8 unless there is any special reason.
(Meaning of the service target gamma data and
purpose of registration)
This work must be executed only when the color balance is custom-
ized by SIM 46-21.
If the color balance is not customized, there is no need to perform this
work.
Execute SIM 46-21 to adjust the color balance (Manual) according to
the user request (customized color balance). Then use the adjust-
ment pattern printed in this mode to register the service target gamma
data with SIM 63-7.
This will revise the service target gamma data.
It is recommendable to record the adjustment pattern printed in the
above procedure. By using the adjustment pattern, the same color
balance target can be registered in another machine. It is also useful
to register the service target gamma data again.
Be careful, however, not to fold the pattern or avoid discoloration and
dirt.
Basically the service target gamma data must be registered immedi-
ately after completion of the color balance adjustment (Manual) with
SIM 46-21.
If a considerable time has passed after completion of the color bal-
ance adjustment (Manual) with SIM 46-21, the color balance of the
adjustment pattern after a considerable time differs from that before a
considerable time. Do not use such an adjustment pattern.
Whether the service target gamma data are correct or not can be de-
termined by the following.
When the adjustment result of SIM 46-24 color balance adjustment
(Auto) by selecting the service target is abnormal or unsatisfactory:
In this case, the service target gamma data may be incorrect.
The possible cause is incorrectness or abnormality of the color bal-
ance adjustment pattern used when registering the service target
gamma data of the color balance adjustment (Auto) with SIM 63-7.
The color balance adjustment pattern is printed after the color bal-
ance adjustment (Manual) with SIM 46-21. The possible cause lies in
this procedure.
b. Setup procedure
(Procedure to set the an optional color balance (gamma)
as the service target)
1) Two sheets of color patch image (adjustment pattern) are output-
ted in the copy color balance adjustment (manual adjustment)
(SIM 46-21). (ADJ M17/ADJ 3)
At that time, when the color balance is shifted from the standard,
an adjustment is required. If not, there is no need to adjust.
If an optional color balance is required according to the user’s re-
quest, an adjustment is required.
2) Enter the SIM 63-7 mode.
3) Press the SETUP key.
4) Set the color patch image (adjustment pattern) paper properly ad-
justed and printed in the copy color balance adjustment (manual
adjustment) (SIM 46-21) (ADJ M17/ADJ 3) on the original table.
The color patch image (adjustment pattern) printed by SIM 64-2
may be used. In this case, check that the printed image is proper.
(The other color patch images (adjustment patterns) printed by an-
other machine may be used.)
Set the paper on the original table so that the darker density side
comes on the left side. Then place 5 sheets of white paper on the
color patch image (adjustment pattern).
Output
A: Default color balance (gamma) 
target (fixed)
B: Factory color balance (gamma) 
target (fixed)
C: Service color balance (gamma) 
target (variable)
Input
7 –  38
If it is difficult to adjust the color balance adjustment (Manual) with
SIM 46-21 satisfactorily, do not register the service target gamma
data with SIM 63-7.
5) Press the EXECUTE key.
The color patch image (adjustment pattern) is read.
6) Press the REPEAT key and set the second color patch image (ad-
justment pattern) on the original table.
The color balance (gamma) target setup level of each color can be
checked with K/C/M/Y keys.
The setup level values must be in the ascending sequence of B - 0. If
there is no change or the sequence is reversed, it is judged as an ab-
normality.
In case of an abnormality, resolve the problem and check again.
7) Press the OK key.
The color balance (gamma) corresponding to the color patch im-
age (adjustment pattern) printed in the copy color balance adjust-
ment (manual adjustment) (ADJ M17/ADJ 3) is set as the service
target.
(Procedure to set the default (standard) color balance
(gamma) as the service target)
Do not execute this procedure unless there is any special reason.
Only when the factory target is judged as abnormal in the
automatic color balance adjustment by SIM 46-24, this procedure
is required in the following case:
When the ICU EEPROM data are destroyed by U2 trouble.
When SIM 63-8 is executed, the service target gamma data are
changed to the default target gamma data determined by the machine
design.
When the color balance adjustment (Auto) is executed with the serv-
ice target gamma data set to the default target gamma, a virtually sat-
isfactory result will be obtained.
1) Enter the SIM 63-8 mode.
2) Press the EXECUTE key.
3) Press the YES key.
The service target becomes the same as the default (standard)
target.
ADJ 4
Low-density area density adjustment
(Normall unnecessary to adjust)
NOTE for SIM 46-1 and 46-2:
The major purpose of these simulations is to delete background copy
simply.
SIM 46-1 and 46-2 are used to adjust the copy density in the low-den-
sity area, and they do not affect the density in the high-density area.
Note that the tone and the color phase may be changed greatly if the
set value is changed greatly.
When an extreme background copy is produced, use ADJ M17/ADJ 3
Color balance adjustment (Manual) (SIM 46-21) instead of this proce-
dure.
The adjustment result of SIM 46-1 is reflected evenly to all the color
copy modes.
The adjustment result of SIM 46-2 is reflected evenly to all the mono-
chrome copy modes.
1) Enter the SIM 46-1 or 46-2 mode.
(AR-C150)
(AR-C250/C160/C270)
2) Select the copy mode to be adjusted with the scroll key.
3) Enter the adjustment value with the 10-key, and press the [OK]
key.
To increase the density in the low-density area, set a greater adjust-
ment value. To reduce the density, set a lower adjustment value. The
adjustment in the low-density area can be adjusted individually for
each copy mode.
The greater the set value is, the greater the density in the low-density
area is, and vice versa. (The density in the high-density area is not
changed.)
4) Cancel the simulation mode, and make a copy in the normal mode
to check the copy density in the white area and the low-density
area by using the test chart (UKOG-0283FCZZ).
In this simulation mode, press CLOSE key to jump to the normal copy
mode and make actual copies of the service chart and user docu-
ments. In this manner, the adjustment result can be checked.
The adjustment can be performed also by switching between the
simulation mode and the normal copy mode alternately and checking
the adjustment result with actual copies.
7 – 39
Page of 127
Display

Click on the first or last page to see other AR-C150 (serv.man4) service manuals if exist.