DOWNLOAD Sharp AR-C150 (serv.man4) Service Manual ↓ Size: 36.13 MB | Pages: 127 in PDF or view online for FREE

Model
AR-C150 (serv.man4)
Pages
127
Size
36.13 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / ARC150 250-Service Manual
File
ar-c150-sm4.pdf
Date

Sharp AR-C150 (serv.man4) Service Manual ▷ View online

[Sub scan registration adjustment pattern]
(Example) Set the simulation set values as shown below.
A: 100
Set value
A: 73 (=100 – 27)
B: 112
B: 129 (=112 + 17)
C: 95
C: 110 (=95+15)
7 –  16
[How to read the pattern]
When deflection is made to the positive (+) side in the rough adjustment, increase the value on the positive (+) side.
When the deflection is made to the negative (–) side in the rough adjustment, increase the value on the negative (–) side.
If the rough adjustment pattern or the fine adjustment pattern is not in
the above range, perform the following procedures
5) Calculate the shift from the adjustment reference position for each
adjustment mode.
The sum of the shift of rough adjustment reference and the shift of
fine adjustment is the actual shift.
Shift (Correction value) = Rough adjustment shift + Fine adjust-
ment shift
The interval between scales of the rough adjustment reference
corresponds to 20. Be careful of polarities of the shift (positive or
negative) when calculating.
6) Select the mode to be adjusted with the scroll key.
7) Add or reduce to or from the current adjustment value, enter the
obtained value, and press the [OK] key.
When the shift (correction value) is positive:
Adjustment value = Current adjustment value + Shift (Correc-
tion value)
When the shift (correction value is negative:
Adjustment value = Current adjustment value – Shift (Correc-
tion value)
8) Press the [EXECUTE] key.
The adjustment pattern is printed.
Check that the conditions of procedure 4) are satisfied.
Repeat procedures 4) – 8) until the conditions of procedure 4) are
satisfied.
NOTE: Before performing this adjustment, SIM 44-20 or 44-31 (drum
phase adjustment) must have been adjusted properly.
20
C
C
B
A
20
When the read value is 27
(= 20+7)
When the read value is –27
(= –20–7)
(Example)
When the simulation is set to 105, 
newly set to 78 (= 105 –  27).
A: Rough adjustment pattern
B: Fine adjustment pattern
C: Adjustment range
(Example)
When the simulation is set to 105, 
newly set to 132 (= 105 + 27).
7 –  17
ADJ M11
Image distortion adjustment
This adjustment must be performed in the following cases:
When the scanner (reading) section is disassembled.
When a copy image distortion occurs.
ADJ 1
Scanner (Reading) unit parallelism
adjustment
1) Loosen the screw which is fixing the scanner unit A and the drive
wire, and remove the scanner unit A from the drive wire.
2) Manually turn the scanner drive gear to bring the scanner unit B
into contact with the stopper.
At that time, if the scanner unit B makes contact with the two stop-
pers on the front and the rear frame simultaneously, the parallel-
ism of the scanner unit B is proper.
If not, perform the following procedures.
3) Loosen the fixing screw of the scanner unit drive pulley on the
side where the scanner unit B is not in contact with the stopper.
4) While keeping the scanner unit drive shaft stationary, turn the
scanner unit drive pulley manually so that the scanner unit B
makes contacts with two stoppers on the front and the rear frame
side simultaneously. (Change the relative positions of the scanner
unit drive pulley and the drive shaft.)
5) Fix the scanner unit drive pulley fixing screw which was loosened
in procedure 3).
6) Perform procedure 2).
Repeat procedures 3) –  6) until the parallelism of the scanner unit
B becomes proper.
7) With the scanner unit B in contact with two stoppers on the front
and the rear frame side simultaneously, slide the scanner unit A
until it comes to the right end of the frame, and fix it to the drive
wire with the fixing screw.
Scanner unit A
Scanner unit B
7 –  18
ADJ 2
Image sub scanning direction distortion
adjustment
1) Make a test chart on A3 (11 
×
 17") paper as shown below. (Draw
a rectangular with four right angles.)
2) Set the test chart made in procedure 1) on the document table.
(Leave a space of about 30mm between the reference position
and the test chart. With the document cover open, make a copy
on A3 (11 
×
 17").
3) Check for distortion in the sub scanning direction.
If La = Lb, there is no distortion.
If there is some distortion in the sub scanning direction, perform the
following procedures.
4) Loosen either of two fixing screws of the scanner unit drive pulley.
(Either one on the front or the rear side will do.)
5) With the scanner unit drive shaft kept stationary, turn the scanner
unit drive pulley manually to change the parallelism of scanner
units A and B. (Change the relative positions of the scanner unit
drive pulley and the drive shaft.)
6) Tighten the scanner unit drive pulley fixing screw.
Repeat procedures 2) –  6) until the condition of procedure 3) is
satisfied.
ADJ 3
Image scanning direction distortion
adjustment
1) Make a test chart on A3 (11 
×
 17") paper as shown below. (Draw
a rectangle with four right angles.)
2) Set the test chart made in procedure 1) on the document table.
With the document cover open, make a copy on A3 (11 
×
 17").
3) Check for distortion in the main scanning direction.
If the four angles of the rectangle on the copy are right angles,
there is no distortion. (Completion of the adjustment)
If there is some distortion in the main scanning direction, perform the
following procedures
4) Check for a difference between the right distortion and the left dis-
tortion (balance).
If Lc = Ld, there is no difference between the left distortion and the
right distortion.
If the above condition is satisfied, go to procedure 6).
If the above condition is not satisfied, perform the following proce-
dures.
Lc
Ld
Lc
Ld
Copy A
Copy B
Left distortion is equal
to right distortion.
Lc = Ld
Left distortion is not equal
to right distortion
           Lc 
 Ld
7 –  19