DOWNLOAD Sharp AR-507 (serv.man4) Service Manual ↓ Size: 469.71 KB | Pages: 26 in PDF or view online for FREE

Model
AR-507 (serv.man4)
Pages
26
Size
469.71 KB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / AR287 337 407 507-Service Manual
File
ar-507-sm4.pdf
Date

Sharp AR-507 (serv.man4) Service Manual ▷ View online

8 - 7
Purpose
Adjustment/Operation test/check
Function
(Purpose)
Used to check and adjust the operation of the separa-
tion charger voltage and its control circuit.
Section
Image process
(Photoconductor/
Developing/Transfer/
Cleaning)
Others
Operation/
Procedure
The separation charger output voltage in printing the
front and the back of paper can be adjusted and
checked.
1. Select the print mode with [
­
] key and [
¯
] key.
2. Enter the adjustment value with the 10-key pad.
3. Press the [EXECUTE] key.
The [EXECUTE] key is highlighted, the adjustment value entered in
procedure 2 is set, and the voltage corresponding to the set value is
supplied.
After supplying the voltage for 30 sec, the [EXECUTE] key returns to
the normal display.
If the [EXECUTE] key is pressed while the voltage is supplied, the
voltage output is stopped and the [EXECUTE] key returns to the nor-
mal display.
FROMT MODE: Front surface print (with the paper feed tray and
manual paper feed tray)
BACK MODE: Back surface print (with duplex paper feed)
(AR-287/337)
(AR-407)
(AR-507)
22
22 - 1
Purpose
Operation data output/Check (Display/Print)
Function
(Purpose)
Used to check the print out count of each section in
each operation mode. 
(Used to check the maintenance timing.)
Item
Counter
Operation/
Procedure
nnnnnnnn : Counter value
22 - 6
Purpose
Operation data output/Check (Display/Print)
Function
(Purpose)
Used to output the list of the setting and adjustment
data (simulations, counters).
Item
Data
Adjust/Setting data
Operation/
Procedure
When installing or servicing, execute this simulation to
print and store the adjustment values and setting data
for use in the next servicing. (Memory trouble, PWB re-
placement, etc.)
In this case, the print conditions can be set optionally.
1. Select the setup item.
 (The selected item is highlighted.)
2. Set the item and conditions with the 10-key pad.
3. Press the [EXECUTE] key to print various data.
A: Paper feed mode
  1: Manual paper feed
  2: Upper paper feed tray
  3: Lower paper feed tray
  4: Desk upper paper feed tray
  5: Desk middle paper feed tray
  6: Desk lower paper feed tray
  7: Large capacity paper feed tray
26
26 - 10
Purpose
Setting
Function
(Purpose)
Used to allow entry of the software key input for the
network scanner.
Item
Operation
Operation/
Procedure
1. After entering the sub code of the simulation, enter
the software key in the obtained frame of "NEW."
2. When the obtained number is entered with the 10-key (max. 9 dig-
its), the entered number is displayed in the frame of "NEW." After
entering the number, press the [OK] key, and the entered number
is stored. 
3. Reset with the CA key, and the scanner function is enabled. 
*
Only when SCSI (20 channels/NS1) setup is completed.
If the scanner key input is made without setup, it is rejected.
4. Special note
AR-287/337
AR-407/507
7 – 53
4/5/2000
When the SCSI channel is set to "20," if a software key which
does not correspond to the setup is entered, the setup of "20" is
changed to "1."
26 - 12
Purpose
Setting
Function
(Purpose)
Used to enter the Diagnosis function key input. 
Item
Operation
Operation/
Procedure
1. After entering the sub code of the simulation, enter
the software key in the obtained frame of "NEW."
2. When the obtained number is entered with the 10-key (max. 9 dig-
its), the entered number is displayed in the frame of "NEW." After
entering the number, press the [OK] key, and the entered number
is stored.
3. The Alert/Status E-Mail send function with attached data of the
Remote E-Mail Diagnosis System is enabled. 
26 - 13
Purpose
Setting
Function
(Purpose)
After completion of copier job in copier interruption dur-
ing a printer job, the print job is resumed in synchroni-
zation with the auto clear timer (key operation) setup
time [10-240]. By making the setup below, the print job
is resumed in 0 sec. (However, the auto clear function
is enabled with the setup time of key operation. Also,
this simulation and auto clear are not synchronized.)
Item
Operation
Operation/
Procedure
When this simulation is executed, the current set value
is displayed. At that time, the set value can be changed
with the 10-key.
When the [OK] key is pressed, the current set value is
stored in the EEPROM.
26 - 22
Purpose
Setting
Function
(Purpose)
Used to set the specification (language display) for the
destination. (Excluding the Japan models.)
Item
Specifications
Operation/
Procedure
Select the language to be used according to the table
below. 
Display Language 
ENG.(US)
English(US)
ENG.(UK)
English(UK)
FRENCH
French
SPANISH
Spanish
GERMAN
German 
ITALIAN
Italian
SWEDISH
Swedish
DUTCH
Dutch
26 - 32
Purpose
Setting
Function
(Purpose)
When the variable speed fan motor is in the ready state
and the process temperature is in the range of 36° –
45°, the PWM duty is set in percentage.
Item
Operation
Operation/
Procedure
When this simulation is executed, the current set value
is displayed. At that time, select the fan motor with [
­
]
key and [
¯
] key. Then the set value can be changed
with the 10-key. 
When [
­
] key or [
¯
] key is pressed, the current set value is stored in
the EEPROM. 
VFM1&2&4
Adjustment range of 50 – 100% in 1% increment
PCFM VFM5&6 Adjustment range of 50 – 100% in 1% increment
26 - 44
Purpose
Setting
Function
(Purpose)
Used to set the model of the unit which is connected to
the SCSI I/F of ICU PWB.
Section
ICU
Item
Specifications
Interface/Communication
Operation/
Procedure
A is at the left of B when viewed from the rear side.
 0:
No connection
 1:
Printer controller
  3:
External printer controller
AR-287/337
AR-407/507
4/5/2000
7 – 54
 4:
AXIS controller
  8:
Tandem connection (Initiator)
10:
Tandem connection (Target)
20:
Network scanner controller (NS1)
Either of the above values is set.
*
AR-287 is not provided with the tandem setting. 
However, the display is not changed. When tandem setup is tried, it
is rejected.
26 - 52
Purpose
Setting
Function
(Purpose)
Used to set whether white paper discharge count up is
performed or not.
("White paper" means insertion paper in the OHP inser-
tion paper mode (without copy), cover paper in the
cover paper insertion mode (without copy)/back cover,
and white paper in the duplex exit mode (CA etc.).)
Item
Operation
Operation/
Procedure
When this simulation is executed, the current set value
is displayed.
Under this state, the set value can be changed with the 10-key.
When the OK key is pressed, the currently set value is stored in the
EEPROM.
Set value
Content
A
0
White paper count up is not performed.
1
White paper count up is performed.
Destination
Default
Japan/Australia
0 (Count up is not performed.)
Others
1 (Count up is performed.)
When set to 0 (count up is nor performed), the following counters do
not count up.
·
COPIES counter
·
Total counter
·
Maintenance counter
·
Developer counter
·
Department management counter
·
The signal (PNC) for the external auditor (mechanism counter) is
not outputted.
50
50 - 1
Purpose
Adjustment
Function
(Purpose)
Used to adjust the copy image position and the void
area (image loss) on the print paper in the copy mode.
(The same adjustment can be made with SIM 50-2
(simple method).)
Item
Picture quality
Image position
Operation/
Procedure
1. Select the adjustment item with [
­
], [
¯
] keys.
2. Enter the adjustment value with the 10-key.
3. Press the [OK] key. (The adjustment value entered in procedure 2
is set.)
Descriptions on adjustment items
A. Document scan start position adjustment value (RRC-A)
Used to adjust the timing of outputting the image lead edge signal
(SCAN signal) after starting document scanning. (0 – 99: Refer-
ence value 50)
B. Resist roller clutch OFF timing adjustment value (RRC-B)
Used to adjust the timing of turning ON the resist roller after recep-
tion of the resist signal (LD_START). (0 – 99: Reference value 50)
C. Rear edge void quantity adjustment value (DEN-B)
Used to set the void quantity on the rear edge. (0- 99: Reference
value 30)
D. Image loss quantity set value (IMAGE LOSS)
Used to set the image loss quantity. (0 – 99: reference value 20)
E. Lead edge void quantity set value (DEN-A)
Used to set the void quantity on the document lead edge. (0 – 99:
Reference value 20)
Adjustment procedure
1. Set the image loss quantity (IMAGE LOSS) and the paper lead
edge void quantity (DEN-A) to desired values. (0 – 99:
0.1mm/step)
2. Adjust the document scan start position (RRC_A) so that the im-
age loss quantity of an actual copy image becomes the set value
of procedure 1. (0 – 99: 0.29mm/step)
3. Adjust the resist roller clutch ON timing (RRC_B) so that the lead
edge void quantity of an actual copy image becomes the set value
of procedure 1. (0 – 99: 0.24mm/step)
4. Adjust the rear edge void quantity (DEN_B). (0 – 99: 0.1mm/step)
50 - 2
Purpose
Adjustment
Function
(Purpose)
Used to adjust the copy image position and the void
area (image loss) on the print paper in the copy mode.
(Simple adjustment)
(This simulation allows the same simulation with SIM
50-1 more simply. )
Item
Picture quality
Image position
Operation/
Procedure
1. Select the adjustment item with [
­
], [
¯
] keys.
2. Enter the adjustment value with the 10-key.
3. Press the [OK] key. (The value entered in procedure 2 is set.)
Used to adjust the lead edge by entering the lead edge shift on each
lead edge of 400% copy.
AR-287/337
AR-407/507
7 – 55
4/5/2000
Descriptions on adjustment items
A. Distance from the image lead edge to 10mm of the scale (Platen
400%) (L1)
B. Distance from the paper lead edge to the image lead edge (L2)
C. IMAGE LOSS
D. DEN-A
E. DEN-B
Adjustment procedures
1. Set the image loss quantity (IMAGE LOSS) and the paper lead
edge void quantity (DEN-A) to desired values. (0 – 99:
0.1mm/step)
2. Set L1/L2 to 0.
3. Make a 400% copy with OC, and enter the shift quantity to L1/L2.
(0 – 999: 0.1mm/step)
4. Repeat procedure 3 so that the paper lead edge void quantity of
the actual copy image becomes the set value of procedure 1. 
5. Adjust the rear edge void quantity (DEN_B). (0 – 99: 0.1mm/step)
50 - 26
Function
(Purpose)
Used to set the folding margin of center binding.
Operation/
Procedure
When this simulation is executed, the current set value
is displayed.
Under this state, the set value can be changed with the
10-key.
When the OK key is pressed, the currently set value is
stored in the EEPROM.
(1 step: 0.1mm)
Item
Content
Range
Default
A
Clear quantity of the folding section of center
binding left image (when the OC is used)
0 ~ 99
20
B
Clear quantity of the folding section of center
binding right image (when the OC is used)
0 ~ 99
30
C
Clear quantity of the folding section of center
binding left image (when the RSPF is used)
0 ~ 99
0
D
Clear quantity of the folding section of center
binding right image (when the RSPF is used)
0 ~ 99
0
(AR-287/337/407)
(AR-507)
51
51 - 3
Purpose
Setting
Function
(Purpose)
Used to set the clutch OFF time. (AR-507 Europe and
U.K. only)
Item
Operation
Operation/
Procedure
When this simulation is executed, the current set value
is displayed.
At that time, the set value can be changed with [
­
] key and [
¯
] key.
When [
­
], [
¯
], and [OK] keys are pressed, the current set value is
stored in the EEPROM.
Destination
Default
TRC2
Europe
80
U.K.
80
TRC1H
Europe
60
U.K.
60
(Europe/U.K.)
61
61 - 2
Purpose
Adjustment
Function
(Purpose)
Used to adjust the scanner (exposure) laser power (ab-
solute value) in the copy mode.
Section
Laser (Exposure)
Item
Operation
Operation/
Procedure
(AR-287/337)
All must be set to "8."
AR-287/337
AR-407/507
4/5/2000
7 – 56
Page of 26