DOWNLOAD Sharp AR-405 (serv.man10) Service Manual ↓ Size: 924.36 KB | Pages: 85 in PDF or view online for FREE

Model
AR-405 (serv.man10)
Pages
85
Size
924.36 KB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / AR405 Service Manual-Simulation Codes
File
ar-405-sm10.pdf
Date

Sharp AR-405 (serv.man10) Service Manual ▷ View online

3 - 6
Purpose
Adjustment
Function
(Purpose)
Used to adjust the finisher stacking capability. (Used to adjust the stop position of the finishser paper width
direction alignment plate (jogger). This adjustment is made by changing the width direction alignment plate home
position by the software.) 
(Target model:AR-S330/280/285/335)
Section
Sorter/Finisher
Item
Operation
Operation/
Procedure
1. Select B mode with [
] and [
] keys.
2. Select the paper size by entering the numbers (0 or 1) with the 10-key pad.
3. Select A mode with [
] and [
] keys.
4. Enter the adjustment value with the 10-key pad.
5. Press the [EXECUTE] key.
The value entered in procedure 4 is set.
The finisher’s jogger starts operation. During operation, the [EXECUTE] key is highlighted.
If the [EXECUTE] key is pressed while it is highlighted, the load operation is interrupted.
Note
4
4 - 2
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of sensors and detectors in the paper feed section (desk feed, large capacity tray)
and the related circuit.
Section
Paper transport
Item
Operation
Operation/
Procedure
The operating conditions of the sensors and detectors in the paper feed section are displayed.
The active sensors and detectors are highlighted.
AR-405
8 – 11
1/21/1999
Desk Unit Sensor
LCC Unit Sensor
DDOPSW
Door open sensor 
LRE
Remaining quantity sensor 
DPOD1
Paper exit transport sensor 1cs 
LUD
Upper limit sensor 
DPOD2
Paper exit transport sensor 2 cs 
LDD
Lower limit sensor 
DPOD3
Paper transport sensor 3cs 
LPED
Paper empty sensor 
DLUD1
1cs Lift upper limit sensor 
LPFD
Paper exit sensor 
DPED1
1cs Paper empty sensor 
LDSW
Door open SW 
DCSPD1
1cs remaining quantity detection 1
LTOD
Body connection sensor 
DLUD2
2xs lift upper limit sensor 
LCD
Cassette detection line 
DPED2
2cs paper empty sensor 
LLSW
Upper limit switch.
DCSPD2
2cs remaining quantity detection 1
DLUD3
3cs lift upper limit sensor 
DPED3
3cs paper empty sensor 
DCSPD3
3cs remaining quantity detection 1
FOUND1
1cs lift unit detection (Installation detection)
FOUND2
2cs lift unit detection (Installation detection)
FOUND3
3cs lift unit detection (Installation detection)
DCSS11
1cs size detection 0
DCSS12
1cs size detection 1
DCSS13
1cs size detection 2
DCSS14
1cs size detection 3
DCSS21
2cs size detection 0
DCSS22
2cs size detection 1
DCSS23
2cs size detection 2
DCSS24
2cs size detection 3
DCSS31
3cs size detection 0
DCSS32
3cs size detection 1
DCSS33
3cs size detection 2
DCSS34
3cs size detection 3
Note
4 - 3
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of the loads in the paper feed section (desk paper feed, large capacity tray) and the
control circuits.
Section
Paper transport
Item
Operation
Operation/
Procedure
1. The names of the loads which can be operated are displayed.
Select the load to be checked with the key, and the selected load is highlighted.
2. Press the [EXECUTE] key.
The load selected in procedure 1 starts the operation.
During the operation of the load, the [EXECUTE] key is highlighted. If the [EXECUTE] key is pressed while it is
highlighted, the operation is stopped.
AR-405
1/21/1999
8 – 12
Desk Unit Output
Lcc Unit Output
DM
Transport motor 
LLED
Dorr open LED 
DLUM1
Lift up motor 1
LPFC
Paper feed clutch 
DLUM2
Lift up motor 2
LPFS
Paper feed solenoid 
DLUM3
Lift up motor 3
LPFM
Transport motor 
DPFS1
Paper feed solenoid 1
LLM
Lift motor 
DPFS2
Paper feed solenoid 2
DPFS3
Paper feed solenoid 3
DPFC1
Paper feed clutch 1
DPFC2
Paper feed clutch 2
DPFC3
Paper feed clutch 3
DTRC
Transport clutch 
The LCC unit lit motor continues lifting up and falling down
Note
5
5 - 1
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of the display, LCD in the operation panel, and control circuit.
Section
Operation (Display/Operation key)
Item
Operation
Operation/
Procedure
The LCD shows the following message.
(The contrast changes in the sequence of Current level 
 MAX 
 MIN 
 Current level 
 MAX 
 MIN in every
2sec.)
AR-405
8 – 13
1/21/1999
During that period, each LED is lighted for 12sec.
 2.0sec.
Note
5 - 2
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of the heater lamp and the control circuit.
Section
Fixing (Fusing)
Item
Operation
Operation/
Procedure
1. Select the lamp to be checked with the key.
2. Press the [EXECUTE] key.
The selected heater lamp repeats ON/OFF in the frequency of 500msec 5 times.
Then the [EXECUTE] key returns to the original display.
When the [EXECUTE] key is pressed during ON/OFF operation of the heater lamp, the heater lamp is turned OFF
and the [EXECUTE] key returns to the original display.
HL1 (LEFT): This lamp is on the left when viewed from the front and it heats the center of the lamp.
HL2 (RIGHT): This lamp is on the right when viewed from the front and it heats both ends of the lamp.
Note
AR-405
1/21/1999
8 – 14
Page of 85
Display

Click on the first or last page to see other AR-405 (serv.man10) service manuals if exist.