Sharp AR-286 (serv.man10) User Manual / Operation Manual ▷ View online

8-19
CHAPTER
8
Date and Time Adjustment
This program is used to adjust the date and time which will be used for
printing date.
When the “DATE AND TIME ADJUSTMENT.” key is pressed, the
following display will appear.
1.
Select an item to be adjusted and adjust the value using
the 
 and 
 keys.
Repeat this step for all desired items.
2.
Press the “OK” key.
If an invalid date (example: February 31) has been entered in
step 1, the “OK” key will be disabled.
Rotation Copy Setting
If this program is set, the image of originals will rotate when the
orientation of the originals does not match that of the copy paper.
Rotation copy will function only when the auto paper select or auto
copy ratio mode has been selected.
When the STAPLE SORT function is used, rotation copy will not be
performed even if this program has been set.
NOTE:
If the image is rotated in reduction copying, the position of the image
in relation to copy paper will vary with the orientations of the originals
and copy paper.
To enable rotation copy, press the check box of “ROTATION
COPY SETTING.” to display a check mark in the check box.
To disable this mode, press the check box of this program
again to clear the check mark in the check box.
KEY OPERATOR PROGRAMS
DATE AND TIME ADJUSTMENT.
YEAR
1998
 MONTH
10
 DAY
12
HOUR
00
 (00~23)
MINUTE
00
OK
KEY OPERATOR PROGRAMS
KEY OPERATOR’S GUIDE
  
Key operator programs
Original
Copy paper
Copy
8-20
CHAPTER
8
Size Setting for [EXTRA]
The paper sizes in the paper trays (except an optional large capacity
tray) can be changed by the users. The copier senses the paper sizes
with the paper size indicators in the paper trays. If a paper size indicator
is set to [EXTRA] and this program is used, the copier can sense paper
sizes as selected on the setting screen.
When the “SIZE SETTING FOR [EXTRA].” key is pressed, the
following display will appear.
1.
Select a paper tray on the touch panel.
2.
Select a paper size for [EXTRA] setting.
To select a size of inch series, press the “INCH” key and
select a paper size.
Select the paper size which matches the paper to be loaded into
the paper tray.
This setting can also be used for paper trays in an optional stand/
500-sheet paper drawer (AR-DE1N).
3.
Press the “OK” key.
KEY OPERATOR PROGRAMS
SIZE SETTING FOR
[EXTRA].
PAPER TRAY
2
1
A3
B5
B4
B5R
A4
A5
A4R
AB
INCH
3
4
OK
EXTRA
KEY OPERATOR PROGRAMS
KEY OPERATOR’S GUIDE
  
Key operator programs
8-21
CHAPTER
8
KEY OPERATOR PROGRAMS
TIMER SETTINGS
The programs of this category are used to set the timers for some
functions. These programs can be selected by pressing the “TIMER
SETTINGS” key and then selecting the desired program key.
Auto Power Shut-off Timer
The auto power shut-off mode is a function to turn off the power
automatically once a programmed length of time has elapsed without
any copier operation after the last copy of a run is made or power is
turned on.
This function lowers the user’s electricity bill, reduces waste of natural
resources, and cuts down on environmental pollution.
The programmed time is set to 60 minutes for this function on
completion of shipment from the factory. The default time can be
changed optionally within the prescribed range of time. We suggest
you set the most appropriate time according to your usage pattern.
Use this program to set the time interval. The time until auto power
shut-off occurs can be set in 1 minute increments up to a 4 hour
maximum.
When the “AUTO POWER SHUT-OFF TIMER.” key is pressed, the
following display will appear.
1.
Enter the time interval using the 
 and 
 keys.
2.
Press the “OK” key.
Auto Clear Setting
Use this program to set the time interval to return the copier to the initial
settings after the last copy of a run has been completed. The time can
be set from 10 to 240 seconds in 10 second increments.
When the “AUTO CLEAR SETTING.” key is pressed, the following
display will appear.
1.
Set the desired time interval using the 
 and 
 keys.
To disable the auto clear, press the check box of “CANCEL
TIMER” to display a check mark in the check box.
2.
Press the “OK” key.
KEY OPERATOR PROGRAMS
AUTO POWER SHUT-OFF
TIMER.
SET THE TIME INTERVAL FROM LAST COPY
UNTIL POWER OFF IN 1 MIN. INCREMENTS.
60
(1~240)
 
min.
OK
TIME:
KEY OPERATOR PROGRAMS
AUTO CLEAR SETTING.
SET THE TIME FOR AUTO CLEAR.
CANCEL TIMER
60
(10~240)
 
sec.
OK
TIME:
KEY OPERATOR’S GUIDE
  
Key operator programs
8-22
CHAPTER
8
KEY OPERATOR PROGRAMS
Preheat Mode Setting
Preheat mode functions to control the power consumption by lowering
the temperature of the fusing unit to a programmed level once a
programmed length of time has elapsed without any copier operation
after the last copy of a run is made or power is turned on. This function
lowers user’s electricity bill, reduces waste of natural resources, and
cuts down on environmental pollution. The programmed time is set to
15 minutes for this function on completion of shipment from the factory.
The default time can be changed optionally within the prescribed range
of time. We suggest you set the most appropriate time according to
your usage pattern.
This program is used to set the time that elapses before the copier
enters the preheat mode after copying is completed. The interval can
be set between 1 and 240 minutes in 1 minute increments.
When the “PREHEAT MODE SETTING.” key is pressed, the following
display will appear.
1.
Set the desired time interval using the 
 and 
 keys.
2.
Press the “OK” key.
Message Time Setting
This program is used to adjust the length of time that messages are
displayed in the range of 1 to 12 seconds in 1 second increments.
When the “MESSAGE TIME SETTING.” key is pressed, the following
display will appear.
1.
Set the time using the 
 and 
 keys.
2.
Press the “OK” key.
KEY OPERATOR PROGRAMS
PREHEAT MODE SETTING.
SET THE TIME FOR PREHEAT MODE.
15
(1~240)
 
min.
OK
TIME:
KEY OPERATOR PROGRAMS
MESSAGE TIME SETTING.
SET THE TIME FOR MESSAGES.
6
(1~12)
 
sec.
OK
TIME:
KEY OPERATOR’S GUIDE
  
Key operator programs