4. Contents of simulations
Main
code
Sub
code
Contents
Details of operation
Initial
value
Set range
1
1
Mirror unit operation
check 
Used to execute scanning at the speed corresponding to the set mag-
nification ratio.
100%
50 ~ 200%
Key operation
Display
Changing the magnification ratio: 
    Fixed magnification ratio key
Set magnification ratio: 
    Fixed magnification ratio LED
2
Optical system sensor
operation check
Used to check MHPS (Mirror home position sensor) ON/OFF state with
the LED on the operation panel. 
Display
<Lighting when the sensor is ON>
MHPS: Paper empty LED
2
1
SPF aging
Used to perform SPF document transport.
The paper size is not detected. (Excluding postcards, extra large sheet of
1m or greater.)
With SPF installed: Single transport operation 
With RSPF installed: Duplex transport operation
2
SPF sensor operation
check 
Used to check sensors in SPF with the LED on the operation panel.
Display
<Lighting at sensor ON>
PW1: JAM LED
PW2: Paper empty LED
PW3: Machine position JAM LED
PW4: SPF JAM LED
PL1: Manual paper feed tray select LED
PL2: Second cassette position JAM LED
P-IN: SPF select LED
P-OUT: Main cassette select LED
3
SPF motor forward
rotation operation check 
Used to rotate the SPF motor forward at the speed corresponding to the
currently set magnification ratio for 10 sec.
100%
50 ~ 200%
Key operation
Display
Magnification ratio change: 
    Fixed magnification ratio key
Set magnification ratio: 
    Fixed magnification ratio LED
4
SPF motor reverse
rotation operation check 
Used to rotate the SPF motor reversely for 10 sec.
8
SPF paper feed solenoid
operation check
Used to drive the SPF paper feed solenoid (PSOL) at the cycle of
500msec ON and 500msec OFF 20 times.
9
SPF reverse solenoid
operation check 
Used to drive the SPF reverse solenoid (RSOL) at the cycle of 500msec
ON and 500msec OFF 20 times.
10
SPF paper exit gate
solenoid operation check 
Used to drive the SPF paper exit gate solenoid (GSOL) at the cycle of
500msec ON and 500msec OFF 20 times.
11
SPF PS release solenoid
operation check 
Used to drive the SPF PS release solenoid at the cycle of 500msec ON
and 500msec OFF 20 times.
3
2
Shifter job separator
sensor operation check 
Used to check the sensors state in the shifter job separator with the LED
on the operation panel. 
Display
<Lighting at sensor ON>
Shifter HP sensor: Machine position JAM LED
Job separator HP sensor: SPF JAM LED
Paper exit full sensor: Second cassette position JAM LED
3
Shifter operation check
Used to drive the shifter motor at the speed of printing of A4 (8-1/2 
×
11"). Pressing the start key or the clear all key moves the shifter to the
home position. 
Key operation
The shifter is moved to the home position: Start key or clear all key
AR-160/160 FM/E [8] SIMULATION 12/1/1998
AR-161
8 – 2
Main
code
Sub
code
Contents
Details of operation
Initial
value
Set range
3
4
Job separator operation
check
Used to drive the job separator one way. Pressing the clear key stops
the job separator at the home position.
Key operation
Stops at the home position: Clear all key
10
Job separator home
position check  
Used to drive the job separator to the home position. Then it is shifted by
the specified number of steps for check, and the position is made as the
origin. It is shifted from the origin by the specified number of steps.
5
1
Operation panel display
check 
Used to light all LED’s on the operation panel for 5 sec.
2
Heater lamp lighting
check, cooling fan motor
operation check 
Used to turn ON the heater lamp for 500msec and OFF for 500msec 5
times. At the same time, the cooling fan is rotated at a high speed. After
checking the heater lamp operation, the cooling fan motor rotate at a low
speed. 
3
Copy lamp lighting check 
Used to light the copy lamp for 5 sec. At that time, the copy lamp
brightness can be changed with the density adjustment key. When this
simulation is canceled, the copy lamp brightness if automatically ad-
justed.   
Key operation
Copy lamp brightness: Density adjustment key
6
1
Paper feed solenoid
operation check 
When the start key is pressed, the selected paper feed solenoid is driven
at the cycle of 500msec ON and 500msec OFF 20 times. 
Key operation
Display
Solenoid selection:
   
Tray 
select 
button
<Lighting at solenoid selection>
Main cassette paper feed solenoid:
        Main cassette select LED
Multi manual paper feed solenoid: 
    Manual 
paper 
feed 
select 
LED
No. 2 cassette paper feed solenoid:
        No. 2 cassette select LED
No. 3 cassette paper feed solenoid:
        No. 3 cassette select LED
No. 4 cassette paper feed solenoid:
        No. 4 cassette select LED
Resist roller solenoid:
    Machine 
position 
JAM 
LED
No. 2 cassette transport solenoid:
        No. 2 cassette position JAM LED
No. 3 cassette transport solenoid:
        No. 3 cassette position JAM LED
No. 4 cassette transport solenoid:
        No. 4 cassette position JAM LED
Paper out 1 solenoid: Paper empty LED
Paper out 2 solenoid: SPF JAM LED
Paper out 3 solenoid: SPF select LED
10
Main cassette
semi-circular roller drive
Used to rotate the semi-circular roller of the main cassette one turn to
face it downward.
7
1
Aging with JAM with
warmup time display
Used to start warmup and count and display the warmup time every
second. After completion of warmup, count up is terminated and the
ready lamp is lighted. When the clear key is pressed and the copy
quantity is entered and the start key is pressed, copying is made to make
the set quantity of copies. At that time, the paper size does not matter. 
1 ~ 9
Key operation
Copy quantity setting: Numeric keys
AR-160/160 FM/E [8] SIMULATION 12/1/1998
AR-161
8 – 3
Main
code
Sub
code
Contents
Details of operation
Initial
value
Set range
7
2
Aging without JAM with
warmup time display
Used to start warmup and count and display the warmup time every
second. After completion of warmup, count up is terminated and the
ready lamp is lighted. When the clear key is pressed and the copy
quantity is entered and the start key is pressed, copying is made to make
the set quantity of copies. At that time, the paper size does not matter. 
1 ~ 99
Key operation
Copy quantity setting: Numeric keys
4
Warmup saving
Used to bring the machine to the ready state without warmup. 
6
Intermittent aging (with
paper)
After completion of warmup, counting is stopped and the ready lamp is
lighted. When the copy quantity is entered and the start key is pressed,
copying is made to make the set quantity of copies. After 3 sec standby,
copying is made again to make the set quantity of copies. After that this
operation is repeated. The paper size does not matter. 
1 ~ 99
Key operation
Copy quantity setting: Numeric keys
7
Intermittent aging (without
paper)
After completion of warmup, counting is stopped and the ready lamp is
lighted. When the copy quantity is entered and the start key is pressed,
copying is made to make the set quantity of copies. After 3 sec standby,
copying is made again to make the set quantity of copies. After that this
operation is repeated. The paper size does not matter. 
1 ~ 99
Key operation
Copy quantity setting: Numeric keys
8
Warmup time display
Used to count and display the warmup time from 0 at every second. 
8
1
Developing bias voltage
output check 
Used to output the developing bias for 30 sec. For the adjustment proce-
dure of the developing bias, refer to the previous descriptions.
2
Main charger voltage
output check (Grid bias
high mode)
Used to output the main charger grid bias voltage at the high mode for
30 sec. For the adjustment procedure of the main charger grid bias
voltage, refer to the previous descriptions.
3
Main charger voltage
output check (Grid bias
low mode)
Used to output the main charger grid bias voltage at the low mode for 30
sec. For the adjustment procedure of the main charger grid bias voltage,
refer to the previous descriptions. 
6
Transfer charger voltage
check 
Used to output the transfer charger voltage for 30 sec. For the adjust-
ment procedure of the transfer charger voltage, refer to the previous
descriptions. 
9
1
Duplex motor forward
rotation operation check 
Used to rotate the duplex motor forward for 30 sec. 
2
Duplex motor reverse
rotation operation check 
Used to rotate the duplex motor reversely for 30 sec. 
4
Duplex motor rotation
speed adjustment
After completion of warmup, the ready lamp is lighted and the currently
set duplex motor rotation speed set value is displayed.
When the set value is entered and the start key is pressed, the set value
is stored.
Key operation
Duplex motor rotation speed set value: Numeric keys
5
Duplex motor switchback
time adjustment
After completion of warmup, the ready lamp is lighted and the currently
set duplex motor switchback time set value is displayed.
When the set value is entered and the start key is pressed, the set value
is stored.
Key operation
Duplex motor switchback time set value: Numeric keys
10
Toner motor operation
check 
Used to operate the toner motor for 30 sec.
Note: If this simulation is executed with the toner hopper installed, toner
is automatically supplied to the developer. Be careful of overtoner.
14
Trouble (except for U2)
cancel
Used to cancel troubles except for U2. 
16
U2 trouble cancel
Used to cancel U2 trouble. 
17
PF trouble cancel
Used to cancel PF trouble.
AR-160/160 FM/E [8] SIMULATION 12/1/1998
AR-161
8 – 4
Main
code
Sub
code
Contents
Details of operation
Initial
value
Set range
20
1
Maintenance counter clear
Used to clear the maintenance counter. 
2
21
1
Maintenance cycle setting
Used to display the currently set maintenance cycle at the numbers
shown at right. When the set value is entered and the start key is
pressed, the set value is stored. 
Key operation/Display
0: 2500 sheets
1: 5000 sheets
2: 15000 sheets
3: 30000 sheets
4: 150000 sheets
5: FREE (999999 sheets)
2
Mini maintenance counter
display
Used to display the currently set mini maintenance cycle at the numbers
shown at right. When the set value is entered and the start key is
pressed, the set value is stored. 
Key operation/Display
0: 2500 sheets
1: 5000 sheets
2: 10000 sheets
3: FREE (999999 sheets)
22
1
Maintenance counter
display
Used to display the current maintenance counter value. 
1
2
Maintenance preset value
display
Used to display the current maintenance preset value (set with SIM
21-1). 
1
3
JAM memory display
Used to display a JAM generated during copying on the JAM position
display on the operation panel. Max. 30 recent jams are stored. 
Key operation
Display
JAM history select: 
    Magnification ratio key
The history number (1 ~ 30) is displayed
on the display.
The JAM position LED corresponding to
the history number is lighted. 
4
Total JAM counter display
Used to display the current total JAM counter value. 
1
5
Total counter display
Used to display the current total counter value. 
1
6
Developing counter
display
Used to display the current developing unit counter value. 
1
7
Developing preset counter
value display
Used to display the current mini maintenance preset value (set with SIM
21-2). 
1
8
SPF counter display
Used to display the current SPF counter value. 
1
9
Paper feed counter display
Used to display the current paper feed counter value for each paper feed
port. 
1
Key operation
Paper feed port selection: Tray select key
12
Drum counter display
Used to display the current drum counter value. 
1
14
Flash ROM version display
Used to display the version number of the flash ROM of each PWB.
15
Trouble memory display
Used to display the actually occurred trouble codes on the display on the
operation panel. When the start key is pressed during the main code
display, the sub code is displayed. Max. 20 recent trouble codes are
stored.
Key operation
Display
Sub code display: Start key
Hysteresis 1 
 10: The upper digit of 
  display 
"A" 
 "J" lights up.
Hysteresis 11 
 20: The upper digit of 
    display "A: 
 "J" blinks.
Trouble code history
select: Magnification ratio
display key
Display without trouble code
Main code: "----"
Sub code: "00"
1: Each counter display method
To display 12345: 123 (0.75 sec) 
 Blank (0.35sec) 
 456 (0.75 sec) 
 Blank (1.0 sec) 
 repetition
2: Display after clearing each counter 
000 (0.75 sec) 
 Blank (0.35sec) 
 000 (0.75 sec) 
 Blank (1.05 sec) 
 Repetition
AR-160/160 FM/E [8] SIMULATION 12/1/1998
AR-161
8 – 5
Page of 13
Display