Sharp AR-155 (serv.man11) Service Manual ▷ View online

(2) Soft switch clear mode
Procedure
LCD
Operation
1
Press FUNCTION, 9, 
∗, 8, #, 7.
DIAGNOSTIC MODE
ROM VERSION = <version>
2
Press ENTER.
DIAGNOSTIC MODE
SELECT MENU(
←  →)
3
Press 0, 2.
02:SOFT SW CLEAR
1:OK 2:CANCEL
4
Press 1.
DIAGNOSTIC MODE
SELECT MENU(
←  →)
The soft switches setup is reset to the default,
and this mode is terminated.
(3) ROM & RAM check mode
Procedure
LCD
Operation
1
Press FUNCTION, 9, 
∗, 8, #, 7.
DIAGNOSTIC MODE
ROM VERSION = <version>
2
Press ENTER.
DIAGNOSTIC MODE
SELECT MENU(
←  →)
3
Press 0, 3.
03:ROM/RAM CHECK
4
(Normal case)
ROM/RAM OK
(RAM error)
RAM ERROR
Two short beeps
(ROM error)
ROM ERROR
One short beep
(4) Signal send mode
Procedure
LCD
Operation
1
Press FUNCTION, 9, 
∗, 8, #, 7.
DIAGNOSTIC MODE
ROM VERSION = <version>
2
Press ENTER.
DIAGNOSTIC MODE
SELECT MENU(
←  →)
3
Press 0, 4.
04:SIGNAL SEND
SELECT SIGNAL
4
Press 
← or → repeatedly to select the target
signal.
<signal type>
PRESS ENTER KEY
For <signal type>, refer to TABLE-3.
5
When the target signal is displayed, press ENTER.
mode # = 1 
→ 10
mode # = 2 
→ 20
mode # = 3 
∼ 6 → 30
mode # = 7 
→ 40
10
1:NO SIGNAL
The relay is turned ON.
11
Press STOP.
04:SIGNAL SEND
SELECT SIGNAL
The relay is turned OFF.
“NO SIGNAL” mode is terminated.
12
(To terminate this mode)
Press STOP.
This mode is terminated.
20
2:DTMF
DTMF # =
21
Press any NUM key(0 
∼ 9) or ∗ or #.
2:DTMF
DTMF # = <pressed key>
The DTMF signal corresponding to the
pressed key is sent.
22
Press STOP.
2:DTMF
DTMF # =
23
(To continue)
Go to 21.
(To change the signal kind)
Press STOP.
04:SIGNAL SEND
SELECT SIGNAL
(To terminate this mode)
Press STOP twice.
This mode is terminated.
30
<signal type>
SELECT SPEED
31
Press 
← or → to select the target speed.
<signal speed>
PRESS ENTER KEY
For <signal speed>, refer to TABLE-4.
AR-F151
9  – 16
Procedure
LCD
Operation
32
When the target speed is displayed, press ENTER.
<signal speed>
SELECT DATA
33
Press 
← or → to select the target data to be sent.
<data>
PRESS ENTER KEY
For <data>, refer to TABLE-5.
34
When the target data is displayed, press ENTER.
<signal speed>
<data>
The selected signal is sent.
35
Press STOP.
<signal speed>
SELECT DATA
Signal send stop
36
(To change data only)
Go to 33.
(To change speed)
Press STOP.
<signal type>
SELECT SPEED
(To change the signal kind)
Press STOP twice.
04:SIGNAL SEND
SELECT SIGNAL
(To terminate this mode)
Press STOP 3 times.
This mode is terminated.
40
7:TONE
SELECT FREQUENCY
41
Press 
← or → to select the target frequency.
<signal freq.>
PRESS ENTER KEY
For <signal freq.>, refer to TABLE-4.
42
When the target frequency is displayed, press
ENTER.
<signal freq.>
The selected signal is sent.
43
Press STOP.
7:TONE
SELECT FREQUENCY
Signal send stop
44
(To change the frequency only)
Go to 41.
(To change the signal kind)
Press STOP.
04:SIGNAL SEND
SELECT SIGNAL
(To terminate this mode)
Press STOP twice.
This mode is terminated.
TABLE-3: Signals in the Signal send mode
MODE #
MENU
DISPLAY
1
No signal
1:NO SIGNAL
2
DTMF
2:DTMF
3
V.17
3:V.17
4
V.29
4:V.29
5
V27ter
5:V27ter
6
FLAG
6:FLAG
7
Tone (CED/CNG)
7:TONE
TABLE-4: Speed/Frequency in the Signal send mode
MODE #
MENU ITEM 1
MENU ITEM 2
MENU ITEM 3
MENU ITEM 4
3
1:V.17 14400BPS
2:V.17 12000BPS
3:V.17 9600BPS
4:V.17 7200BPS
4
1:V.29 9600BPS
2:V.29 7200BPS
5
1:V27ter 4800BPS
2:V27ter 2400BPS
6
1:FLAG 300BPS
7
1:TONE 2100Hz
2:TONE 1100Hz
TABLE-5: Data which is sent in the Signal send mode
MODE #
MENU (DATA)
DISPLAY
1
00000000b
1:00000000b
2
11111111b
2:11111111b
3
01010101b
3:01010101b
AR-F151
9  – 17
(5) Image memory clear mode
Procedure
LCD
Operation
1
Press FUNCTION, 9, 
∗, 8, #, 7.
DIAGNOSTIC MODE
ROM VERSION =
<version>
2
Press ENTER.
DIAGNOSTIC MODE
SELECT MENU(
←  →)
3
Press 1, 0.
10:IMAGE MEM CLEAR
1:OK 2:CANCEL
4
Press 1.
DIAGNOSTIC MODE
SELECT MENU(
←  →)
The image data are cleared and this mode is
terminated.
(6) Dial test / adjustment mode (Pulse 10PPS)
Procedure
LCD
Operation
1
Press FUNCTION, 9, 
∗, 8, #, 7.
DIAGNOSTIC MODE
ROM VERSION =
<version>
2
Press ENTER.
DIAGNOSTIC MODE
SELECT MENU(
←  →)
3
Press 1, 4.
14:DIAL TEST 10 PPS
MAKE RATIO = ##%
The current make ratio setup is displayed on ##.
4
Press 
← or →.
(If there is no need to adjust, no need to press.)
14:DIAL TEST 10 PPS
MAKE RATIO = ##%
Press 
← to decrease by 1%.
Press 
→ to increase by 1%.
5
Press ENTER.
“1590” is dialed.
6
(Adjustment/test end)
Press STOP.
This mode is terminated.
(To continue adjustment/test)
Return to 4.
(7) Dial test mode (Tone)
Procedure
LCD
Operation
1
Press FUNCTION, 9, 
∗, 8, #, 7.
DIAGNOSTIC MODE
ROM VERSION =
<version>
2
Press ENTER.
DIAGNOSTIC MODE
SELECT MENU(
←  →)
3
Press 1, 6.
16:DIAL TEST TONE
“123456789
∗0#” is dialed.
This mode is terminated.
(8) Print out soft switch mode
Procedure
LCD
Operation
1
Press FUNCTION, 9, 
∗, 8, #, 7.
DIAGNOSTIC MODE
ROM VERSION =
<version>
2
Press ENTER.
DIAGNOSTIC MODE
SELECT MENU(
←  →)
3
Press 2, 1.
21:PRINT SOFT SW
The soft switch list is printed.
This mode is terminated.
AR-F151
9  – 18
(9) Panel check mode
Procedure
LCD
Operation
1
Press FUNCTION, 9, 
∗, 8, #, 7.
DIAGNOSTIC MODE
ROM VERSION =
<version>
2
Press ENTER.
DIAGNOSTIC MODE
SELECT MENU(
←  →)
3
Press 4, 2.
42:FAX PANEL TEST
4
Press any key.
42:FAX PANEL TEST
<key name>
The name of the pressed key is displayed in the
lower stage of the LCD.
5
Press STOP.
This mode is terminated.
(10) Signal detect mode
Procedure
LCD
Operation
1
Press FUNCTION, 9, 
∗, 8, #, 7.
DIAGNOSTIC MODE
ROM VERSION =
<version>
2
Press ENTER.
DIAGNOSTIC MODE
SELECT MENU(
←  →)
3
Press 4, 3.
43:SIG. DETECT
4
(When DTMF signal is detected)
43:SIG. DETECT
DTMF:<number>
(When CNG signal is detected)
43:SIG. DETECT
CNG
(When QUIET signal is detected)
43:SIG. DETECT
QUIET
(To terminate this mode)
Press STOP.
This mode is terminated.
(11) Long distance comm select mode
Procedure
LCD
Operation
1
Press FUNCTION, 9, 
∗, 8, #, 7.
DIAGNOSTIC MODE
ROM VERSION =
<version>
2
Press ENTER.
DIAGNOSTIC MODE
SELECT MENU(
←  →)
3
Press 4, 4.
44:LONG DIST COMM
1:SET 2:CLEAR
To terminate this mode, press STOP.
4
Select the mode.
To register 
→ 10
To cancel registration 
→ 20
10
Press 1.
SET
ENTER # OR RAPID
11
Press the desired one touch key or the speed
dial (2 digits) to be registered.
SELECT SPEED
1:9600BPS 2:4800BPS
12
Select the speed. (Press 1 or 2.)
<Name or Number>
STORED
13
Return to 3.
20
Press 2.
CLEAR
ENTER # OR RAPID
21
Press the desired one-touch key or speed dial (2
digits) to be canceled.
<Name or Number>
CLEARED
22
Return to 3.
Note:
● One-touch keys and speed dials which are not registered cannot be designated.
● When one-touch keys and speed dials which are registered are canceled, this setup is also canceled.
● The group key and the polling key cannot be designated.
AR-F151
9  – 19
Page of 31
Display

Click on the first or last page to see other AR-155 (serv.man11) service manuals if exist.