DOWNLOAD Sharp AR-120E (serv.man2) Service Manual ↓ Size: 267.77 KB | Pages: 28 in PDF or view online for FREE

Model
AR-120E (serv.man2)
Pages
28
Size
267.77 KB
Type
PDF
Document
Handy Guide
Brand
Device
Copying Equipment / AR120E 121E 150 151 155 156 F151
File
ar-120e-sm2.pdf
Date

Sharp AR-120E (serv.man2) Handy Guide ▷ View online

User Programs
Version 2.0
Issue 05/00
21
SHARP ELECTRONICS (UK)  LTD
COPIER TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
CUSTOM SETTINGS (Key Operator/User Programs)
Auto Power Off Setting
Pre-Heat Timer Setting
Auto clear time
Stream feed (SPF models)
Auto power off setting
The User Programs allow the parameters of certain functions to be set, reset,
changed or cancelled as desired.
User Program Modes Entry
Press and hold the right and left EXPOSURE ADJUSTMENT KEYS
simultaneously for 5 seconds.
The Drum, Jam, Toner & Maintenance lamps will flash at the same time and
“- -“ will show in the copy quantity display.
The following chart shows which programs can now be selected.  Enter the function
name value followed by the set code value.
FUNCTION
NAME 1
SET
CODE
FUNCTION
NAME 2
SET
CODE
FUNCTION
NAME 3
SET
CODE
FUNCTION
NAME 4
SET
CODE
FUNCTION
NAME 5
SET
CODE
0
(Cancel
)
0
(30
secs)
0
(2 mins)
0
(Cancel)
0
(Cancel)
1
(30
secs)
1
(60
secs)
1
(5 mins)
1
(Set)
1
(Set)
2
(60
secs)
2
(90
secs)
2
(15 mins}
3
(90
secs)
3
(30 mins)
4
(120
sec)
4
(60 mins)
Auto
Clear
5
(10
secs)
Pre-heat
Auto
Shut
Off
5
(120min)
Stream
Feed
(With
Doc
Feed)
Auto
Shut off
Setting
1) Auto clear-Elapsed time between job completion and the machine returning to standard conditions.
2) Pre heat mode setting – Elapsed time between job completion and the machine entering pre-heat mode.
3) Auto shutoff – Elapsed time between job completion and the machine switching to Shut Down.
4) Stream feed – Selection or de-selection of stream feeding mode when using the document feeder
5) Auto shut-off setting – Selection or de-selection of auto shut off mode  shown in 3)
Electrical Description
Version 2.0
Issue 05/00
22
SHARP ELECTRONICS (UK)  LTD
COPIER TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
AR-FX3 FAX  & AR-SP3 SPF & RSPF UNITS
AR-SP3
The AR-150/151/155 & AR-120E supply 5vdc and 24vdc to the document feeder.
All of the switches and sensors utilise DC voltages to operate.  A source voltage of
24VDC is used to supply the motors, solenoids, and switches within the document
feeder while 5VDC is used by the various photo-detectors.
SPID is used to detect the presence of a document within the paper feed unit, and
SPPD
detects document feed. There are no adjustments  available for the  sensors. The
SPF motor SPFM is a DC stepping motor.
Adjustments may be required to the SPF lead edge position (Sim50-01)
AR-FX3
The AR-FX3 is a similar unit to the AR-SP3 in its operation
However, this unit contains the Fax option.
R-SPF
The R-SPF works in a similar way to the SPF. There is a gate which inverts the
original when Duplex copying is being carried out for 2
nd
 side copying
Fault Finding
Version 2.0
Issue 05/00
23
SHARP ELECTRONICS (UK)  LTD
COPIER TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
This is a copy of the faults on Sharpsearch for the latest information please check
www.tradenet.sharp.co.uk/tech/sharpsearch.(1/3/01)
Abnormal
Noise
Model
Fault
Advice
Comments
All
Optics juddering
CCD not set up or faulty PSU PWB
Connectivit
y
Model
Fault
Advice
Comments
AR150/155
What Printer Option
ARPG1 (GDI Print kit has USB or
parallel interface)
OR
ARPB9 (PCL Print Kit has USB or
parallel interface)
ARF151
What Printer Option
ARPG1 (GDI Print kit has USB or
parallel connector)
AR120E
What printer option
AL-11PK
Electrical
Model
Fault
Advice
Comments
Error Code
Model
Fault
Advice
Comments
All
E7-04 / E7-05
CCD or Flat Cable
If copy lamp does not light during
black and white correction, change
CCD unit. If ribbon cable is defective
copy lamp will still light but E7-04 will
be displayed
All
H4
When an H4 code is displayed and
the Thermostat is identified as the
defective part, make sure to replace
the Thermistor part
RDTCT0128FCZZ
 in conjunction
with the Thermostat 
CTHM-
0019FC52
.
A ROM has been developed to
eliminate this trouble. Version 1.5.6
SEE T/B 35
AR150
P +Maintenance
Maintenance cycle set incorrectly
SET Sim 21-01
AR155
L4-01
Main motor fault
Check for Transfer "Arc" & pressure
spring
Firmware
Model
Fault
Advice
Comments
Miscellaneo
us
Model
Fault
Advice
Comments
All 
(NEW)
Handy Guide
Fault Finding
Version 2.0
Issue 05/00
24
SHARP ELECTRONICS (UK)  LTD
COPIER TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
All
How do I access secret test
commands
C-EXP-C-Copy Ratio
All
How do I access test
commands
C-Exp-C-Exp
Paper Feed
Model
Fault
Advice
Comments
Poor Copy
Quality
Model
Fault
Advice
Comments
All 
(NEW)
Blank strip in all modes
Remove sticker from dev unit
All
Condensation forming on
underside of glass, and
cabinets
Exhaust fan not connected and so
not allowing the heat to be extracted
from the machine.
Reconnect the fan.
ARF151
When printing out from fax
gives vertical lines in image
area
Replace Fax PWB
(
CPWBX0042TS51
)
Copy Sample
All
Missing section of copy
Replace Laser unit
Copy Sample
All
Missing copy area (rear frame) Perform T.C. 64-01 to eliminate
optical section
Additional labels attached to dev'
cartridge will cause blank areas if
they unpeel (blocks laser path)
Specificatio
n
Model
Fault
Advice
Comments
AR150
Access to meter
Hold down Clear key for 5 seconds
Same for all Puma's
Peripheral
Model
Fault
Advice
Comments
Page of 28
Display

Click on the first or last page to see other AR-120E (serv.man2) service manuals if exist.