DOWNLOAD Sharp PN-L802B (serv.man2) Service Manual ↓ Size: 874.69 KB | Pages: 21 in PDF or view online for FREE

Model
PN-L802B (serv.man2)
Pages
21
Size
874.69 KB
Type
PDF
Document
Handy Guide
Brand
Device
Monitor / Installation Guidelines (with Sharp stand)
File
pn-l802b-sm2.pdf
Date

Sharp PN-L802B (serv.man2) Handy Guide ▷ View online

PN-L802B Installation Guidelines <Rev1.0> February 2012 
CONFIDENTIAL 
Precautions in installing and moving
 
Precautions in installing and handling 1 
The display surface is made of glass. 
Please use rear handgrip and underside of 
the display while installing and moving. 
Please do not hold surface, sensor side, 
the edge and power button of the display.  
It is possible to cause damage and 
malfunction of display. Please be careful 
not to drop the display. 
 
Caution for Installing 
Prior to installing the PN-L802B, please refer to following items carefully in order to use PN-L802B for long term reliable service. 
-   The accompanying stand is for temporary use until the display installed formally. It is not for permanent use and please do not turn on power of the  
    monitor when the temporary stand is used.   
-   Please fasten a USB cable with cable clamp to the cabinet. 
-   Please use a mounting bracket which can support 4 times weight of the display. The wall on which displays are mounted must support 4 times total  
    weight of the display and mounting bracket (etc. concrete wall / concrete pillar). 
-   Only vertical installation perpendicular to level surface is recommended, and the limitation of the inclination angle is between 0 to 20 degrees upward. 
-   Usable temperature range of this display is 5℃-35℃. Using in other condition may cause failure and deterioration. 
    Please keep enough space to avoid heating. 
-   Please set this display keeping out of direct sunlight. It may cause failure and deterioration. 
-   It is necessary to take measures against dust such as regular cleaning in a dusty area. 
-   For safety, please give measures for preventing fall of display. 
-   The ground connection is necessary when the power plug is connected.  
    
Please ask the professional dealer/contractor if you can’t keep the ground connection. 
- 
Please refer to the “SAFETY PRECAUTIONS”, “TIPS AND SAFETY INSTRUCTION” and “MOUNTING   
  
PRECAUTIONS” which is described in the operation manual of the display as well. 
- Please 
be careful that the warranty can’t be applied if these precautions are not kept. 
×
Caution 
The holding positions are changed from 
PN-L702B/L602B. 
Please be careful to hold the edge of the 
PN-L702B/L602B display, and do not hold 
lower part of the bezel. 
PN-L802B Installation Guidelines <Rev1.0> February 2012 
CONFIDENTIAL 
Precautions in installing and handling 2 
Worker position, assignment of work and cautions at lifting up the display. 
Please wear gloves and safety shoes when you lift up this display. 
For lifting up the display 6 people is required. (Ex. Moving display from the package to wheeled platform.) 
Following the image below, please check the position and assignment for each worker, and lift up the display to set the stand. 
※Please refer to P9 andP10 if you set this display to the stand (PN-ZS80F) which is recommended by SHARP. 
    
You can’t complete installation by these steps below. 
× 
WorkerA; 
hold handle1 with left hand. 
hold handle3 with right hand. 
WorkerB; 
hold handle2 with left hand. 
hold the underside of the main body 
with right hand. 
*Please do not hold the corner of the 
display. 
 
WorkerC; 
hold the underside of the 
main body with both hands. 
WorkerD; 
hold the underside of the main 
body with both hands. 
*please be careful not to touch the 
power button. 
WorkerE; 
hold handle5 with right hand. 
hold the underside of the main 
body with left hand. 
*please do not hold the corner 
of the display and the power 
button. 
WorkerF; 
hold handle4 with right hand. 
hold handle6 with left hand. 
PN-L802B Installation Guidelines <Rev1.0> February 2012 
CONFIDENTIAL 
Precautions for orientation 
About orientation   
- Only vertical installation perpendicular to level surface is recommended.  
-The limitation of the inclination angle is between 0 to 20 degrees upward.   Even within 20 degrees 
   range, please consult individually when installing with inclination.  
Only vertical installation is recommended. 
Within 20 degrees 
More than 20 
 degrees 
Installing with inclination is impossible. 
Even within 20 degrees range, 
please consult individually when 
installing with inclination.  
○ 
× 
PN-L802B Installation Guidelines <Rev1.0> February 2012 
CONFIDENTIAL 
Precautions on stand installation 
(SHARP stand) 
Precautions on stand installation 
Please read the user instruction carefully and carry out installation with the stand we SHARP recommend. (PN-ZS80F) 
Please refer to the detailed installation manual for stand assembling. (Supplementary material) 
After stand installation, please lock casters to prevent its unexpected move. 
After installation, please lock front casters forward, 
and rear casters backward. 
Keep a caster locked 
Height after stand installation 
About the height of each display after stand installation, please refer to the following list. (Unit : mm) 
 
   
Display TOP 
Display BOTTOM 
80” 
(with PN-ZS80F) 
70” 
(with PN-ZS701) 
60” 
(with PN-ZS609) 
80” 
(with PN-ZS80F) 
70” 
(with PN-ZS701) 
60” 
(with PN-ZS609) 
Highest position 
2,100 
1,800 
1,800 
943 
818 
915 
Lowest position 
1,800 
1,500 
1,500 
643 
518 
615 
Keep a caster locked 
Keep a caster locked 
Page of 21