Handy Guide
Brand
Device
Monitor / Installation Guidelines (with Sharp stand)
File
pn-l802b-sm2.pdf
Date

Sharp PN-L802B (serv.man2) Handy Guide ▷ View online

PN-L802B Installation Guidelines <Rev1.0> February 2012 
CONFIDENTIAL 
Carrying Package 
12 
Precautions for carrying 1 
Carrying the display with wheeled platform needs at least 
4 people. Hold each side of display with 2, and hold front 
and rear  sides with 2. 
- Please carry package with a pallet by forklift or hand-lift. 
If you can’t use those machineries, please remove the display from package and carry it with wheeled platform. 
  (Removing display needs at least 6 people, and carrying with wheeled platform needs at least 4 people.) 
Please do not carry this display with portrait orientation. 
Please carry it with landscape orientation. 
× 
Please do not carry 
this display with 
portrait orientation. 
Wheeled platform 
   
Width 
(mm) 
Height 
(mm) 
Depth 
(mm) 
Weight 
(kg) 
Package 
468 
1,452 
2,100 
About 140 
Only main body 
135 
1,157 
1,880 
About 102 
Please carry package with forklift or hand-lift. 
 
Caution 
An accompanying stand is for temporary use 
until this display is installed properly. The 
temporary stand can’t be used for permanent use. 
Hand -lift 
Main body size 
PN-L802B Installation Guidelines <Rev1.0> February 2012 
CONFIDENTIAL 
  
Edge of 
the body 
Entrance 
location 
Package 
Main body 
Depth 
Width 
Depth 
Width 
45° 
1,900 
1,900 
1,500 
1,500 
150 
1,900 
2,000 
1,500 
1,700 
250 
1,900 
2,100 
1,500 
1,800 
Using elevator 
13 
Precautions for carrying 2 
The space to carry in 
    Enough space in an elevator is necessary to carry the display with it. 
      
Caution : Please do not hit package or the main body to the entrance or  
                        bottom of elevator. 
※In case the arrangement angle is 0°,  
    the same size frontage with carrier is necessary. 【mm】 
Following to the  image and the list below, please check the angle 
and the size of an elevator in case there isn’t enough depth. 
Depth   
   :  The depth of an elevator 
Width 
   :  The width of an elevator 
Frontage 
   :  The size of frontage of an  
                                    elevator 
Entrance location    :  The distance between the side 
                                   of an elevator and the frontage 
Arrangement angle:  The angle of the main body to  
                                   arrange it in an elevator 
The main body 
Width 
Depth 
Angle of the main body 
Frontage 
Location of entrance 
PN-L802B Installation Guidelines <Rev1.0> February 2012 
CONFIDENTIAL 
The space to carry in 
14 
Precautions for carrying 3 
1. The space to carry in 
Please carry the main body with wheeled platform to the installation place. 
 The following space is necessary to pass through with wheeled platform  
(wheeled platform size : Width : 300mm or less, Height : 150mm or less) 
 
   2. The space of corners 
  When there is a corner on the carrying course, more   
   than 1,200mm/1,000mm width(Package/only the  
   main body) is necessary. 
  Caution : Please do not hit the side of package to the corner. 
 
wall 
wall 
wall 
The main body 
wall 
wall 
Ceiling 
wheeled platform 
   
Width 
Height 
Package 
500mm or more 
1,650mm or more 
Only the main body 
300mm or more 
1,400mm or more 
   
Space 
Package 
1,200mm or more 
Only the main body 
1,000mm or more 
Package : 1,200mm 
Only the main body : 1,000mm 
Package : 1,650mm 
Only the main body : 1,400mm 
Package : 500mm 
Only the main body : 300mm 
                                 (Width of wheeled platform ) 
Package : 1,200mm 
Only the main body : 1,000mm 
wall 
PN-L802B Installation Guidelines <Rev1.0> February 2012 
CONFIDENTIAL 
Using elevator 
15 
1.  The space to carry in 
    Enough space in an elevator is necessary to carry the display with it. 
     
Caution : Please do not hit package or the main body to an entrance or bottom of elevator. 
   
Width 
Depth 
Width of entrance 
Height 
Package 
*
 
350mm or more 
2,000mm or 
more 
350mm or more  1,100mm or more 
After 
construction 
1,050mm or more 
2,250mm or 
more 
1,000mm or more 
1,850mm or more 
(without display 
2,150mm or more 
(with display 
Package : 2,000mm or more 
Only the main body : 2,250mm or more 
Package : 1,100mm or more 
Only the main body : 1,850mm or more 
The main body 
•Assumption of temporary portrait orientation for    
  transportation. 
  
Please keep properly position when it’s carried by truck or   
  stored for long period. 
Package : 350mm or more 
Only the main body : 1,050mm or more 
de
pth
 
width 
Width of entrance 
Precautions for handling package of floor stand/carrying after construction 1 
Page of 21