Sharp PN-L703B (serv.man3) Service Manual ▷ View online
PN-L703A/L703B, PN-70TA3/70TB3, PN-L603A/L603B, PN-60TA3/60TB3
SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4- 19
8-2. WHEN REPLACING THE PANEL OR WHEN AN OLD PWB DOES NOT OPERATE
When the white balance setting information is reset in the PC system input mode, the setting information of the AV system input mode is
reset, too. Therefore, be sure to reset in the PC system input mode.
1) Select the PC system input mode with [INPUT] button.
Select one of DisplayPort, HDMI1/2//3[PC] and D-SUB[RGB]
modes.
2) Any image is displayed on the screen.
3) SERVICE MENU2 is displayed.
4) Select “WHITE BALANCE SETTING” with [VOL + ()], [VOL -
(↓)] buttons, and press [ENTER] button.
The WHITE BALANCE SETTING menu is displayed.
“(PC)” is displayed on the title column.
5) Use [VOL + ()], [VOL - (↓)] buttons to select “LEVEL” and
press [ENTER] button.
The LEVEL menu is displayed.
6) Select “RESET” with [VOL + ()], [VOL - ()], [BRIGHT -
( )],[BRIGHT + ()] buttons and press [ENTER] button.
7) Check to confirm that the set value is changed as shown below.
8) Select “OK” with [BRIGHT - ( )],[BRIGHT + ()] buttons, and
press [ENTER] button.
The display returns to the WHITE BALANCE SETTING menu.
9) Select “RESET” with [VOL + ()], [VOL - ()], [BRIGHT -
( )],[BRIGHT + ()] buttons and press [ENTER] button.
10) Check to confirm that all the set value is changed as shown
below.
PN-L703A/70TA3
11) Select “OK” with [BRIGHT - ( )],[BRIGHT + ()] buttons, and
press [ENTER] button.
The WHITE BALANCE SETTING menu is terminated.
12) Perform the WHITE BALANCE setting read procedures to
check that all settings have been properly changed.
PN-L703A/L703B, PN-70TA3/70TB3, PN-L603A/L603B, PN-60TA3/60TB3
SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4- 20
9. WHITE BALANCE SETTING TOOL OPERATING PROCEDURE
9-1. WHITE BALANCE SETTING TOOL
OPERATING CONDITIONS
The operating conditions of the White balance setting read tool of
the information display are as follows.
OS
(32bit Only)
- Windows 8
- Windows Vista
- Windows 7
Communication
port
- LAN(100 BASE-TX / 10BASE-TX)
■ When connected to the information display
with a LAN cable
Refer to the followings of [7. INSTRUCTIONS FOR LAUNCHER
TOOL] to connect the information display and the PC.
■ Connected to the information display with a LAN cable
■ How to prepare the network settings
■ How to set PC automatically with using DHCP
■ How to set PC manually without using DHCP
■ How to set Information Display with using DHCP
■ How to set Information Display without using DHCP
■ How to confirm the connection of PC and Information display
9-2. START-UP OF THE WHITE BALANCE
SETTING TOOL
Press [White Balance] button of the Service Tool Launcher.
9-3. USE INSTRUCTIONS OF THE WHITE
BALANCE SETTING TOOL
■ How to read the settings
The procedures of writing the settings that have been previously
readout with use of the White Balance Setting Tool are as follows.
1) Press [Connection Setting...] button to configure the
communication settings.
2) Turn ON the power of Information Display.
3) Press [Read& Save] button to select the setting file.
4) When all settings have been read out, the set values are
displayed and the dialogue box of file save appears. At this
point, the default file name is “[Model Name]_[Serial Number]
_[Date(YYYYMMDD)].wni”.
After confirming the file name, press [Save] button to save the
settings.
5) Confirm that the “K” mark does not appear on the upper left of
screen.
If the “K” mark is displayed, please perform the writing
procedures once again.
6) Confirm that the “Level” values from the read settings are the
same as the values in the above illustration. If the Level values
that you’ve got don’t agree with the above settings, the setting
data cannot be taken over. In this case, refer to the
procedures: “WHEN REPLACING
THE PANEL OR WHEN AN OLD PWB DOES NOT
OPERATE” and perform the reset of settings to set the default.
(Normally, this case doesn’t happen unless changes are
made individually.)
<CAUTION>
-
When the following messages: “This Monitor is not Support. Is
write processing continued?,” “Writing data is not for this
monitor.
Is write processing continued?,” “Serial Number is different
between monitor and writing data. Is write processing
continued?,” or “Model Name is different between monitor and
writing data. Is write processing continued?” are displayed, the
data you are trying to write may not be the one which the
display previously read out.
Check if it is the right data, and perform the writing once again.
PN-L703A/L703B, PN-70TA3/70TB3, PN-L603A/L603B, PN-60TA3/60TB3
SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4- 21
■ How to write the settings
The procedures of writing the settings that have been previously
read out with use of the White Balance Setting Tool are as follows.
1)Press [Connection Setting...] button to configure the
communication settings.
2) Turn ON the power of Information Display.
3) Press [LoadFile...] button to select the setting file.
4) Press [Write] button, and the set values are written.
5) Confirm that the “K” mark does not appear on the upper left of
screen.
If the “K” mark is displayed, please perform the writing
procedures once again.
<CAUTION>
When the following messages: “This Monitor is not Support. Is
write processing continued?,” “Writing data is not for this monitor.
Is write processing continued?,” “Serial Number is different
between monitor and writing data. Is write processing
continued?,” or “Model Name is different between monitor and
writing data. Is write processing continued?” are displayed, the
data you are trying to write may not be the one which the display
previously read out.
Check if it is the right data, and perform the writing once again.
9-4. WHEN REPLACING THE PANEL OR WHEN
AN OLD PWB DOES NOT OPERATE
The procedures of writing the settings that have been previously
readout with use of the White Balance Setting Tool are as follows.
The procedures of resetting the settings to default are as follows.
1) Press [Connection Setting] button to configure the
communication settings.
2) Turn ON the power of Information Display.
3) Press [Reset] button. The White Balance settings are set to
default.
4) Confirm that the “K” mark does not appear on the upper left of
screen.
If the “K” mark is displayed, please perform the resetting
procedures once again.
<CAUTION>
-
When the following messages: “This Monitor is not Support. Is
write processing continued?,” “Writing data is not for this monitor.
Is write processing continued?” or “Model Name is different
between monitor and writing data. Is write processing continued?”
are displayed, the display which you are trying to initialize may not
be this model. Check if it is the right model, and perform the
initialization procedures once again.
(MEMO)
WHEN THE MESSAGE: “TIME OUT. CANNOT
CONNECT.
PLEASE CONFIRM SETTING.” IS DISPLAYED
-
Check the power state of the connected Information Display.
If “Read & Save” is executed when the display is in a STANDBY
state, it fails in rare cases. Make sure that the display is in an
ON state, and then press [Read & Save...] button again to read
the settings.
-
Check that the PC which you use is properly connected to the
Information Display via a RS-232C cable.
WHEN THE MESSAGE: “CANNOT OPEN INTERFACE.
CANNOT CONNECT. PLEASE CONFIRM SETTING.” IS
DISPLAYED
-
Check if you are trying to use the COM Port which is in use by
some other tool. If the COM Port is being used, terminate the
tool and then press [Read & Save...] button again to read the
setting values.
WHEN THE MESSAGE: “THIS MONITOR IS NOT
SUPPORT.
IS XXXX PROCESSING CONTINUED?” IS DISPLAYED
-
The connected display is not the model which this tool supports.
Please use the right tool that supports the connected display.
PN-L703A/L703B, PN-70TA3/70TB3, PN-L603A/L603B, PN-60TA3/60TB3
SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4- 22
10. GAMMA SETTING PROCEDURES WITH THE OSD
The Gamma setting is used to correct variability of the half-gradation brightness for each panel. If the panel is not changed, the setting of
the panel is taken over to suppress variability. When the panel is changed, reset to the standard setting. There are two ways of setting: the
setting by the Gamma setting tool and the manual setting with the OSD.
10-1. WHEN THE PWB IS REPLACED (THE PANEL IS NOT CHANGED)
■
■
Reading the Gamma setting values
Read the Gamma setting values of the information display before
replacement.
1) Display any image on the screen.
2) Display SERVICE MENU2.
3) Select [GAMMA SETTING] with [VOL + ()], [VOL - (↓)] buttons,
and press [ENTER] button.
The GAMMA SETTING menu is displayed.
4) Select [LEVEL] with [VOL + ()], [VOL - (↓)] buttons, and press
[ENTER] button.
The LEVEL menu is displayed.
INITIAL VALUES
5) Check to confirm that the setting values are same as the above.
If the setting values are not same as the above, the setting
values cannot be taken over. In such a case, reset the setting
values to the initial data by the procedures described in “When
replacing the panel or when the old PWB does not work.”
(Normally this would not happen, unless the value is changed
individually.)
6) Select [CANCEL] with [VOL + ()], [VOL - ()], [BRIGHT -
( )],[BRIGHT + ()] buttons, and press [ENTER] button. The
display returns to the GAMMA SETTING menu.
7) Memorize the set values of VAL1 - VAL5.
8) Select [CANCEL] with [VOL + ()], [VOL - ()], [BRIGHT -
( )],[BRIGHT + ()] buttons, and press [ENTER] button.
The GAMMA SETTING menu is closed.
■
Writing the Gamma setting values
After replacement of the PWB, write the Gamma setting values
which were read before according to the following procedures..
1) Display any image on the screen.
2) Display SERVICE MENU2.
3) Select [GAMMA SETTING] with [VOL + ()], [VOL - ()]
buttons, and press [ENTER] button.
The GAMMA SETTING menu is displayed.
4) Select [LEVEL] with [VOL + ()], [VOL - ()] buttons, and press
[ENTER] button. The LEVEL menu is displayed.
5) Select [RESET] with [VOL + ()], [VOL - ()], [BRIGHT -
( )],[BRIGHT + ()] buttons, and press [ENTER] button.
6) Select [OK] with [BRIGHT - ( )],[BRIGHT + ()] buttons,
and press [ENTER] button. The set content is saved and the
display returns to the GAMMA SETTING menu.
7) Change the values of VAL1 - VAL5 to the memorized values.
Select VAL1 - VAL5 with [VOL + ()], [VOL - ()] buttons.
Select the value with [BRIGHT - ( )],[BRIGHT + ()] buttons,
and adjust the set value with [VOL + ()], [VOL - ()] buttons.
8) Select [VAL*] on the left edge with [BRIGHT - ( )],[BRIGHT +
()] buttons. Repeat the procedures.
9) Check to confirm that all the set values are properly changed.
10) Select [OK] with [VOL + ()], [VOL - ()] buttons, and press
[ENTER] buttons.
The set content is saved and the GAMMA SETTING menu is
closed.
11) Read the GAMMA setting values to check that all values are
properly set.
Click on the first or last page to see other PN-L703B (serv.man3) service manuals if exist.