ENGLISH
39
E
Example: VOLM0030
VOLM 
 
 30 (“ 
 ” indicates a space.)
* Be sure to input 4 characters for the parameter. Pad with spaces if necessary.
Wrong: VOLM30 
Right: VOLM 
 
 30 
 (“ 
 ” indicates a space. “ 
 ” is the return code (0D
H
, 0A
H
 or 0D
H
).)
If a command has “R” listed for “DIRECTION” in the “RS-232C command table” on page 46, the current
value can be returned by using “?” as the parameter.
Example: 1. If an ID number has not been set:
VOLM????
 From PC to monitor (How much is current volume setting?)
30
 From monitor to PC (Current volume setting: 30)
2. If an ID number has been assigned (For example, ID number = 1)
VOLM 
 
 
?
 From PC to monitor (“ 
 ” indicates a space.)
30 
 001
 From monitor to PC (“ 
 ”  indicates a space.)
<Response code format>
 When a command has been executed correctly
This is returned when execution of the command is
finished.
 When a command has not been executed correctly*
* This is returned when there is no such command, or
when the command cannot be used in the current
state of the monitor (Example: When
“ADJUSTMENT” is used (a command which is
effective when the input mode is “ANALOG”), while
video is displayed (the input mode is “VIDEO”)).
* If there is a bad connection between the PC and
monitor, or if communication has not been
established, nothing is returned (not even ERR).
 If execution of the command is taking some time
With some commands, “WAIT” is returned as a return
value. Wait for a moment, and OK or ERR will be
returned. New commands cannot be received during
this time, even if they are sent.
 If RS-232C is locked
If RS-232C control has been locked with the
operation lock (see page 26), LOCKED is returned
as the returned value.
Communication procedure
Basic operation
<Command format>
When a command is sent from the PC to the monitor, the monitor operates according to the received
command, and sends a response message to the PC.
C1
C2
C3
C4
P1
P2
P3
P4
Return code
Command field
(4 prescribed
alphanumerical
characters)
Parameter field
(4 character string
comprised of:
0-9, +, space, ?)
O
K
Return code
(0D
H
, 0A
H
)
R
R
E
Return code
(0D
H
, 0A
H
)
I
W
T
A
Return code
(0D
H
, 0A
H
)
E
C
D
K
O
L
Return code (0D
H
, 0A
H
)
40
E
PC Operation 
(Continued)
Advanced operation
This section explains commands for daisy chain connection. The basic communication procedure is the
same as in the “Basic operation” section.
<ID numbers>
You can assign a unique ID number to each monitor (see page 31). This allows you to control a particular
monitor in a daisy chain of monitors.
Up to about 20 monitors can be connected, depending on the length of RS-232C cables and installation
environment.
You can assign ID numbers either from the menu screen (using the remote control) or from the PC using
RS-232C cable.
[Example]
If monitors are connected as shown above, you can execute commands like “Set the volume of the
monitor with ID 4 to 20”.
When controlling monitors linked in a daisy chain by designating ID numbers, you should basically avoid
any duplication of ID numbers.
ID numbers do not have to be assigned in ascending order starting from the PC. They can also be
connected as shown below.
[Example]
PC
ID number: 1
ID number: 2
ID number: 3
ID number: 4
PC
ID number: 3
ID number: 2
ID number: 4
ID number: 1
ENGLISH
41
E
<Commands for ID control>
The command examples shown on this page assume the following connection and ID number set up.
IDST......A monitor receiving this command sets its own ID number in the parameter field.
Example: IDST0001
OK 
 001 
  The ID number of this monitor is set to 1.
After linking monitors, you can automatically assign ID numbers by using the IDST command with
the Repeater control (see “Repeater control” on page 43).
[Example]
If you connect monitors as shown above, and use the command “IDST001+”, ID numbers will be set
automatically, as shown below.
[Example]
IDST001+ 
 ID setting command with repeater control
WAIT
OK 
 001 
 “OK” response from ID number: 1
OK 
 002 
 “OK” response from ID number: 2
OK 
 003 
 “OK” response from ID number: 3
OK 
 004 
 “OK” response from ID number: 4 (End)
PC
ID number: 1
ID number: 2
ID number: 3
ID number: 4
PC
Set 1
Set 2
Set 3
Set 4
PC
ID number: 1
ID number: 2
ID number: 3
ID number: 4
Note
42
E
PC Operation 
(Continued)
IDSL ....... The parameter of this command sets the ID number of the monitor.
                The monitor is subject to the next command.
Example:
IDSL0002
The next command is for the monitor with ID number: 2.
WAIT
Searching for monitor with ID number: 2
OK 
 002
Found monitor with ID number: 2
VOLM0030
Sets volume of monitor with ID number: 2 to 30.
WAIT
Processing
OK 
 002
OK response from monitor with ID number: 2
VOLM0020
Sets volume to 20.
OK 
 001
The volume of the monitor with ID number: 1
(the one directly connected to the PC) is set to 20.
IDLK ....... The parameter of this command sets the ID number of the monitor.
                The monitor is subject to all subsequent commands.
Example:
IDLK0002
Following commands are for the monitor with ID number: 2.
WAIT
Searching for monitor with ID number: 2
OK 
 002
Found monitor with ID number: 2
VOLM0030
Sets volume of monitor with ID number: 2 to 30.
WAIT
Processing
OK 
 002
VOLM0020
Sets volume of monitor with ID number: 2 to 20.
WAIT
OK 
 002
IDLK0000
Canceling fixed ID number setting
WAIT
Canceling IDLK
OK 
 002
Cancelation complete
VOLM0010
OK 
 001
The volume of the monitor with ID number: 1
(the one directly connected to the PC) is set to 10.
IDCK ...... Provides screen display of the ID number currently assigned to a monitor, and the ID
number currently set for IDLK (if any).
Example:
(After executing IDLK0002)
IDCK0000
(Parameter has no meaning.)
ID:001 IDLK:002
Returned response. The ID number is also displayed on the monitor screen.
IDCK000+
Repeater control
(If a command is used with repeater control, ID designation using IDSL or
IDLK is canceled.)
WAIT
ID:001 IDLK:002
ID:002 IDLK:002
ID:003 IDLK:002
ID:004 IDLK:002
The IDSL command is
effective only once, for the
immediately succeeding
command.
The IDLK command remains
effective until it is canceled, or
power is shut off.
Page of 64