LCD display
46 cm measured diagonally
Advanced Super-V and Anti Glare Low Reflection
TFT LCD module
Resolution (max.)
SXGA 1280 x 1024 pixels
Displayable colors (max.)
16.77 million colors (8 bit)
Brightness (max.)
220cd/m
2
Dot pitch
0.2805(H) x 0.2805(V) mm
Contrast ratio
400:1
Angle of visibility
Left-right 170°; Up-down 170°
Screen display size
Horizontal 359 mm x Vertical 287.2 mm
Video signal
Analog: Analog RGB (0.7Vp-p) [75
Ω]
Digital: DVI standard based on 1.0
Sync signal
H/V Separate Sync (TTL level: +/-), Sync on
Green, Composite Sync (TTL level: +/-)
Expansion compensation
Digital screening (enlargement VGA/SVGA/XGA
etc. to full screen size.)
Plug & Play
VESA DDC2B compatible
Power management
VESA: based on DPMS
DVI:
based on DMPM
Input signal terminal
DVI-I 29 pin x 2
USB hub function
1 upstream port, 2 downstream ports
(selfpowered hub based on USB standard Rev
1.1)
Audio input terminal
Mini stereo jack
Headphone terminal
Mini stereo jack
Power supply
AC100 - 240V, 50/60Hz
Temperature of operating environment
5 - 35°C
Power consumption
51W (Not using USB hub)
(57W maximum, 5W when in power-saving
mode)
Dimensions (W x D x H) (Units: mm)
395 x 68 x 324
Weight
Approx. 5.7kg
Dimensions (Units: mm)
395
68
324
Digital signal cable:
Approx. 2.0 m
USB cable:
Approx. 2.0 m
Audio cable:
Approx. 2.0 m
22
Specifications
Relevant signal timings (analog)
640x480
800x600
1024x768
1152x864
1280x960
1280x1024
720x400
640x480
832x624
1024x768
1152x870
1280x1024
1024x768
1152x900
1280x1024
31.5kHz
37.9kHz
37.5kHz
35.1kHz
37.9kHz
48.1kHz
46.9kHz
48.4kHz
56.5kHz
60.0kHz
67.5kHz
60.0kHz
64.0kHz
80.0kHz
31.5kHz
35.0kHz
49.7kHz
60.2kHz
68.7kHz
64.0kHz
80.0kHz
48.3kHz
53.6kHz
56.6kHz
61.8kHz
71.8kHz
71.7kHz
81.1kHz
60Hz
72Hz
75Hz
56Hz
60Hz
72Hz
75Hz
60Hz
70Hz
75Hz
75Hz
60Hz
60Hz
75Hz
70Hz
66.7Hz
74.6Hz
75Hz
75Hz
60Hz
75Hz
60Hz
66Hz
70Hz
66Hz
76.2Hz
67.2Hz
76Hz
25.175MHz
31.5MHz
31.5MHz
36.0MHz
40.0MHz
50.0MHz
49.5MHz
65.0MHz
75.0MHz
78.75MHz
108.0MHz
108.0MHz
108.0MHz
135.0MHz
28.3MHz
30.2MHz
57.3MHz
80.0MHz
100.0MHz
108.0MHz
135.0MHz
64.13MHz
70.4MHz
74.25MHz
94.88MHz
108.23MHz
117.01MHz
134.99MHz
Recommended resolution is 1280 x 1024.
All are compliant only with non-interlaced.
Frequencies for Power Macintosh and Sun Ultra
series are reference values. To connect, another
adapter (commercially available) may be
required.
If the monitor is receiving timing signals that are
not compatible, [OUT OF TIMING] will appear.
Follow your computer’s instruction manual to set
the timing so that it is compatible with the
monitor.
If the monitor is not receiving any signal (synch
signal), [NO SIGNAL] will appear.
Power
Macin-
tosh
series
Relevant signal timings (digital)
640x480
800x600
1024x768
1152x864
1280x960
1280x1024
720x400
31.5kHz
37.9kHz
37.5kHz
37.9kHz
48.1kHz
46.9kHz
48.4kHz
56.5kHz
60.0kHz
67.5kHz
60.0kHz
64.0kHz
31.5kHz
60Hz
72Hz
75Hz
60Hz
72Hz
75Hz
60Hz
70Hz
75Hz
75Hz
60Hz
60Hz
70Hz
25.175MHz
31.5MHz
31.5MHz
40.0MHz
50.0MHz
49.5MHz
65.0MHz
75.0MHz
78.75MHz
108.0MHz
108.0MHz
108.0MHz
28.3MHz
Recommended resolution is 1280 x 1024.
All are compliant only with non-interlaced.
For a digital signal input, it can be connected to a
computer with a DVI-compatible output terminal
(DVI-D24 pin or DVI-I29 pin) and which has
SXGA output ability. (Depending on the computer
to be connected, correct display may or may not
be possible.)
If the monitor is receiving timing signals that are
not compatible, [OUT OF TIMING] will appear.
Follow your computer’s instruction manual to set
the timing so that it is compatible with the
monitor.
If the monitor is not receiving any signal (synch
signal), [NO SIGNAL] will appear.
Vsync
Dot
frequency
Display mode
VESA
US text
Hsync
Sun
Ultra
series
Vsync
Dot
frequency
Display mode
VESA
Hsync
US text
23
English
Deutsc
h
Fran
ç
ais
Italiano
Espa
ñ
ol
English
The DVI-I input connector pin
(DVI-I connector with 29 pins)
Power management
The monitor is based on the VESA DPMS and the DVI DMPM standards.
To activate the monitor's Power Management function, both the video card and the computer must
conform to the VESA DPMS standard and the DVI DMPM standard.
DPMS: Display Power Management Signalling
                                                   *Not using USB hub
DMPM: Digital Monitor Power Management
                                      *Not using USB hub
DDC (Plug & Play)
This monitor supports the VESA DDC (Display Data Channel) standard.
DDC is a signal standard for carrying out Plug & Play functions on the monitor or PC. It transfers informa-
tion such as degree of resolution between the monitor and PC. You can use this function if your PC is
DDC compliant and if it is set so that it can detect the Plug & Play monitor.
There are many varieties of DDC due to the differences between systems. This monitor works with
DDC2B.
Specifications
DPMS mode
Screen
Power
H-sync V-sync
consumption
ON
Display on
51W*
Yes
Yes
STANDBY
No
Yes
SUSPEND
Display off
5W
Yes
No
OFF
No
No
DMPM mode
Screen
Power
consumption
ON
Display on
51W*
OFF
Display off
5W
No.
Function
No. Function
1
TMDS data 2-
16
Hot plug detection
2
TMDS data 2+
17
TMDS data 0-
3
TMDS data 2/4 shield
18
TMDS data 0+
4
N.C.
19
TMDS data 0/5 shield
5
N.C.
20
N.C.
6
DDC clock
21
N.C.
7
DDC data
22
TMDS clock shield
8
23
TMDS clock +
9
TMDS data 1-
24
TMDS clock -
10 TMDS data 1+
C1
Analog red image signal
11 TMDS data 1/3 shield
C2
Analog green image signal
12 N.C.
C3
Analog blue image signal
13 N.C.
C4
14 +5V
C5
Analog GND
15 GND
Analog vertically synchronised
signal
Analog horizontally synchro-
nised signal
24
Installing set-up information and the ICC profile (For Windows)
Depending on the computer or OS, it may be
necessary to use the computer to operate the
installation of monitor set-up information etc. If so,
follow the steps below to install the monitor set-up
information. (Depending on the type of computer or
OS, command names and methods may differ.
Please follow the computer’s own operation manual
while reading this.)
About the ICC profile
An ICC (International Color Consortium) profile
is a file that describes the color characteristics
of the LCD monitor. By using an application that
works together with an ICC profile, a high color
resolution can be realized.
Windows98/2000/Me/XP all use the ICC
profile.
When installing Windows98/2000/Me/XP set-
up information (described below), the ICC
profile is also installed. If you would like to
install  the ICC program only, please refer to
Installing the ICC profile on page 26.
When using an ICC profile, set  [COLOR
MODE] and [WHITE BALANCE] to [STD], and
set [HUE] and [SATURATION] to [0].
Installing set-up information
 For Windows95
Installing monitor set-up information into Win-
dows95.
This explanation assumes that the floppy disk drive
is "A drive".
1. Place the Utility Disk into the computer's A
drive.
2. Click on the [Start] button. From [Settings],
choose [Control Panel].
3. Double click on [Display].
4. Click on [Settings], [Advanced Properties], and
[Monitor], then [Change].
5. Click on [Have disk], confirm that [Copy
manufacturer's files from:] is [A:] then click [OK].
6. Confirm that the monitor details are selected,
and click [OK].
7. Check that the monitor details are displayed,
then click [Apply].
8. Click [OK], and close the window.
9. Remove the Utility Disk from the A drive.
 For Windows98
Installing monitor set-up information into Win-
dows98, and setting the monitor's ICC profile as a
predetermined value.
This explanation assumes that the floppy disk drive
is "A drive".
If the "Add new Hardware Wizard" has appeared:
1. Place the Utility Disk into the computer's A
drive.
2. Click [Next].
3. Check [Display a list of all the drivers in a
specific location, so you can select the driver
you want.], then click [Next].
4. When [Models] is displayed, click on [Have
disk], confirm that [Copy manufacturer's files
from:] is [A:], and click [OK].
5. Confirm that the monitor details are selected,
then click [Next], [Next], and [Finish]. If the "Add
New Hardware Wizard" appears, repeat the
installation commands beginning from 2 above.
6. Remove the Utility Disk from the A drive.
If the "Add New Hardware Wizard" has not ap-
peared:
1. Place the Utility Disk in the computer's A drive.
2. Click on the [Start] button. From [Settings],
choose [Control Panel].
3. Double click on [Display].
4. Click on [Settings], [Advanced] and [Monitor].
5. In [Options], check [Automatically detect Plug &
Play monitors] and click on [Change].
6. Click [Next].
7. Click on [Display a list of all the drivers in a
specific location, so you can select the driver
you want.], then click [Next].
8. When [Models] is displayed, click on [Have
disk], confirm that [Copy manufacturer's files
from:] is [A:], and click [OK].
9. Confirm that the monitor details are selected,
then click [Next], [Next], and [Finish].
10. Check that the monitor details are displayed,
then click [Apply].
11. Click [OK], and close the window.
12. Remove the Utility Disk from the A drive.
Page of 32
Display

Click on the first or last page to see other LL-H1813 (serv.man6) service manuals if exist.