4. Specifying the terminal to serve as a back-up master — master
You can assign one satellite to the function of a back-up master. If the master fails during guest
check operation, the assigned terminal will perform the master’s function.
A machine number within the range from 1 to 999999 can be entered.
If zero is entered, there will be no back-up master in the IRC system.
This job can be done in the INLINE SETTING window of the master.
The default setting is 0 (no back-up master).
1.
Enter the PGM2 mode.
2.
Select “SETTING” and touch the
ENTER
key. The
SETTING window will open.
3.
Select “INLINE CONFIG” and touch the
ENTER
key.
The INLINE SETTING window will open.
4.
Move the cursor to the “BMA MACHINE No.” line.
Then enter the machine number of the terminal to
serve as a back-up master and touch the
ENTER
key.
• For determining which satellite should be selected
as the “BMA MACHINE No.,” please consult your
authorized SHARP dealer.
NOTE
The DECLARATION functions in the PGM2 mode enable the back-up master or the master to
declare to serve as the master when the master or back-up master breaks down, and inform
satellites of the master’s or back-up master’s recovery.
For details of these functions, see “Master declaration” and “Recovery declaration” on pages 49–55.
40
5. Specifying whether to enable or disable the system retry
function when a transmission error occurs — master and satellite
You can specify whether the system retry function is disabled or enabled if the communication
between machines does not end successfully.
1.
Enter the PGM2 mode.
2.
Select “SETTING” and touch the
ENTER
key. The
SETTING window will open.
3.
Select “INLINE CONFIG” and touch the
ENTER
key.
The INLINE SETTING window will open.
4.
Move the cursor to the “SYSTEM RETRY” line.
Select “DISABLE” or “ENABLE” with the
•
key
(toggle key) and touch the
ENTER
key.
NOTE
•
If the system retry function is enabled, a transmission job that has ended with an error will not
be finalized immediately. The master waits for a selection of one of the three commands
(RETRY, ABORT and IGNORE) through the keyboard. Then the master retries access to the
satellite that has caused the transmission error or terminates the access as a successful or
unsuccessful transmission depending on the selection made.
•
If the function is disabled, the job is terminated immediately.
•
For further information, see the “System retry function” section on pages 59–60.
•
The default setting is “ENABLE.”
41
6. Reading the contents of the IRC programming — master and satellite
1.
Enter the PGM2 mode.
2.
Select “READING” and touch the
ENTER
key. The
READING window will open.
3.
Select “INLINE CONFIG” and touch the
ENTER
key.
The INLINE READING window will open.
4.
Select “INLINE PRESET” and touch the
ENTER
key.
5
Select “DISPLAY” or “REPORT PRINTER” and touch
the
ENTER
key.
42
• You can also read the same contents of the IRC programming on the display screen.
I N L I N E P R E S E T
T–No.
SYSTEM RETRY ENABLE
∗PGM2 ∗
∗PGM2 ∗
I N L I N E P R E S E T
T–No.
MASTER L I ST
T–No.
001
002
003
004
005
M–No.
000001#
000002#
000003#
000004#
000005#
BACK UP MASTER
T–No.
002
M–No.
000002#
SYSTEM RETRY ENABLE
Terminal number of the master
Terminal number of the satellite
System retry function
(enable/disable)
(enable/disable)
Sample Print (master)
Sample Print (satellite)
List of the machines involved in the IRC system
(terminal no./machine no.)
(terminal no./machine no.)
Back-up master
(terminal no./machine no.)
(terminal no./machine no.)
System retry function
(enable/disable)
(enable/disable)
192.168.000.001
192.168.000.002