DOWNLOAD Sharp XE-A303 (serv.man3) Service Manual ↓ Size: 674.59 KB | Pages: 28 in PDF or view online for FREE

Model
XE-A303 (serv.man3)
Pages
28
Size
674.59 KB
Type
PDF
Document
Service Manual
Brand
Device
ECR / XE-A303 Program Manual
File
xe-a303-sm3.pdf
Date

Sharp XE-A303 (serv.man3) Service Manual ▷ View online

XE-A303 (V)
PROGRAM MODE
2 – 14
5. EASY PROGRAMMING
Easy programming roughly consists of the following two types of pro-
gramming.
1.  Direct key or code entry type.
2.  Guidance message type on usual programming.
Reports that show the contents of individual programming can be
printed.
[PURPOSE]
It aims to be able to program easily by using the guidance messages by
the easy programming.
[OPERATION]
Perform the programming to enter the parameter according to the guid-
ance message.
The guidance message is displayed on the LCD-display every time.
It shows the information related the entry data at each step.
Each programming data and the text data is entered by using a key-
board.
It is used some key as special key to enter each data at the Easy Pro-
gramming operation.
There are follows.
1. DIRECT KEY OR CODE ENTRY TYPE
<Programming method>
At PGM mode, it becomes set up mode, as it pushes a key of a direct
key or code entry that it wants to set up. 
For example:
Push [DEPT1] key, if you want to set up DEPT1 items.
Push [%1] key, if you want to set up %1 item.
After that, every time it pushes [ST] key, a set up item changes with price,
text, programming ... 
To change a programming content, it changes it using a numeric key.
As additional way, [00] key can be used as a incremental while an indi-
cator lights on.
i.e. By pushing [00] key for a digit of parameters, a figure changes 0 
3
3
 ...
The data is changed by pushing [ST] key, and the display shows a con-
tent of the next item.
After that, the operator program the next set up item.
If a set up ends, it pushes [TL] key.
It shows the list of programmable data by this method (“Direct key entry
type”) on the next page.
It shows every set up item and example of display to the following.
<KEY SEQUENCE>
<DEPT> 
<PLU> 
KEY
CONTENTS OF USE
a Numerical key (0, 1 to 9) Used for numerical number entry.
b Double-zero key ([00])
Used for parameter entry and character 
code entry.
c Clear key ([CL])
Used for cancel entry.
d Point key ([.])
Used for decimal point entry and
right moving entry (As right cursor key).
e Multiplication key ([X])
Used for left moving entry (As left cursor key).
f
Subtotal key ([ST])
Used for data decision entry.
g Finalization key ([TL])
Used for programming termination entry.
Function
key
Step
Programmable 
data
Entry type
Default 
(MRS)
DEPT
[DEPTn] 
or 
DEPT 
code + 
[DEPT#]
1
Text
(CHARACTER)
DEPT. 
xx
2
Price
(NUMERIC)
0
3
Entry type
(TOGGLE)
OPEN
4
Selection of TAX1
(TOGGLE)
(
*
1)
5
Selection of TAX2
(TOGGLE)
(
*
1)
6
Selection of TAX3
(TOGGLE)
(
*
1)
7
Selection of TAX4
(TOGGLE)
(
*
1)
8
Registration type 
(TOGGLE)
NORMAL
9
Group no.
(NUMERIC)
(
*
1) (
*
2)
10
Limitation digits
(NUMERIC)
8
(
*
1) DEPT01 - 10
: VAT 1 / Group 1
DEPT11 - 20  : VAT 2 / Group 1
DEPT21 
:   VAT   1   /   G ro u p
10
DEPT22 - 99  : VAT 1 / Group 1
(
*
2) Group 1-9
: (+) department
Group 10
: (-) department
Group 11
: (+) Hash department
Group 12
: (-) Hash department
Function
key
Step
Programmable 
data
Entry type
Default
(MRS)
PLU
PLUn
or
PLU 
code +
[ P L U /
SUB]
1
Text
(CHARACTER) PLU. xxxx
2
Price
(NUMERIC)
0
3
Dept code
(NUMERIC)
01
4
Sign
(TOGGLE)
(+)
5
Type
(TOGGLE)
PLU
XE-A303 (V)
PROGRAM MODE
2 – 15
<(-)> 
(
*
) Please refer function list. (Programming of function text)
<%n>
(
*
) Please refer function list. (Programming of function text)
<EXCHANGE>
(
*
) Please refer function list. (Programming of function text)
 
<RA, PO, CH1, CH2, CR1, CR2> 
(
*
1) Please refer function list. (Programming of function text)
(
*
2) Noncompulsory (Cash, check), inhibit (Credit)
(
*
3) 8 (CA, CH1, CH2, CR1, CR2), 9 (RA, PO)
It shows every set up item and example of display to the following.
<The details of “ENTRY TYPE”>
As it pushes [ST], a set up item advances the next step.
As it pushes [TL], and the set up data writes to the memory, and a set
up of the function ends.
Set up as it pushes other DIRECT PLU KEY on the way (exclude text
programming), and the set up data writes to the memory, a set up of the
next setting starts.
The guidance message is displayed at each programming step.
The following guidance messages are used for easy programming operation.
<Programming for DEPT>
Function
key
Step
Programmable
data
Entry type
Default
(MRS)
(-)
(-)
1
Text
(CHARACTER)
(
*
)
2
Unit price
(NUMERIC)
0
3
Sign
(TOGGLE)
(-)
4
Item
(TOGGLE)
Enable
5
Subtotal
(TOGGLE)
Enable
6
Limitation digits
(NUMERIC)
8
Function
key
Step
Programmable 
data
Entry type
Default
(MRS)
%n
%n
1
Text
(CHARACTER)
(
*
)
2
Rate
(NUMERIC)
0.00
3
Sign
(TOGGLE)
(-)
4
Item
(TOGGLE)
Enable
5
Subtotal
(TOGGLE)
Enable
6
% RATE halo
(NUMERIC)
100.00
Function
key
Step
Programmable 
data
Entry type
Default
(MRS)
EX
EX
1
Text
(CHARACTER)
(
*
)
2
Rate
(NUMERIC)
0.000000
3
OPEN RATE 
ENTRY
(TOGGLE)
Enable
4
PRESET RATE 
ENTRY
(TOGGLE)
Enable
5
TAB
(NUMERIC)
2
Function
key
Step
Programmable 
data
Entry type
Default
(MRS)
RA
PO 
CH1 
CH2 
CR1 
CR2
RA
PO 
CH1 
CH2 
CR1 
CR2
1
Text
(CHARACTER)
(
*
1)
2
Footer print on 
receipt
(TOGGLE)
NO
3
Entry of amount 
tendered
(TOGGLE)
(
*
2)
4
Limitation digits
(NUMERIC)
(
*
3)
KEY ENTRY
OPERATER
NOTE
[DPT1]
  
DEPT1 TEXT 
DEPT1 CODE
A text changes to ENTER [00]-
KEY.
->[00]
Message of “ENTER TEXT” is 
displayed.
Current DEPT1 text is displayed.
Then the cursor is blinking. (
*
)
->066
Text code is inputted.
->[00]
If [00] key is entered and  input-
ted text is addressed.
Then the cursor is blinking.
->EER        
(_is set space)
text
->[ST]
Guidance message
Current setting is displayed.
->200
 
->[ST]
Guidance message
Current setting is displayed.
->[00]
->[00]
->[00]
->[00]
->[ST]
Guidance message
Current setting is displayed.
->[00]
Guidance message
Current setting is displayed.
->[ST]
Guidance message
->[00]
Guidance message
->[ST]
Guidance message
1234567890123456
DEPT . 0 1
0 1
0 . 0 0
ENT ER [ 0 0 ] KEY
0 1                     0 . 0 0
ENT ER T EXT      
0 1                     0 . 0 0
DEPT . 0 1         
0 1                       0 6 8
DEPT . 0 1                
0 1                       0 6 6
BEPT . 0 1                
0 1                       0 6 9
BEER        
0 1                       0 3 2
PR I CE           
0 1                       1 2 3
PR I CE           
0 1                       2 0 0
DEPT  ENT RY T YPE
0 1 OPEN & PRESET
DEPT  ENT RY T YPE
0 1            I NH I B I T ED
DEPT  ENT RY T YPE
0 1  
OPEN
DEPT  ENT RY T YPE
0 1                 PRESET
DEPT  ENT RY T YPE
0 1  
OPEN
S E L E CT   OF   T A X 1
T AX1                   YES
S E L E CT   OF   T A X 1
T AX1                     NO
S E L E CT   OF   T A X 2
T AX2                     NO
SEL ECT   OF  T AX2
T AX2  
      YES
SEL ECT   OF   T AX3
T AX3                     NO
XE-A303 (V)
PROGRAM MODE
2 – 16
(
*
) In case of text setting, you can use [X] or [.] key. 
If you push [X] key, the cursor moves to the left. And if you push [.]
key, the cursor moves to the right.
<CANCEL OPERATION>
In this case, price (200) and text (DRINK) are not written to the preset 
memory.
<Programming for PLU>
(
*
)  In case of text setting, you can use [X] or [.] key. 
 If you push [X] key, the cursor moves to the left. And if you push [.]
 key, the cursor moves to the right.
->[ST]
Guidance message
->[ST]
Guidance message
Current setting is displayed.
->[00]
->[ST]
Guidance message
->11
Guidance message
->[ST]
Guidance message
Current setting is displayed.
->7
Guidance message
->[ST]
  
DEPT2 TEXT 
DEPT2 CODE
RETURN TO 1’st STEP
->[TL]
DEPT1 SET UP TERMINATE
KEY ENTRY
OPERATER
NOTE
[DPT5]
  
DEPT5 TEXT
DEPT CODE
ENTER [00]-KEY TO CHANGE 
TEXT
->[00]
Message of “ENTER TEXT” is  
displayed.
 
->DRINK _
 
->[ST]
Guidance message
->200
 
->[ST]
PRICE IS DECIDED
->[CL]
 
->[CL]
DEPT5 SET UP TERMINATE
KEY ENTRY
OPERATER
NOTE
1234567890123456
SEL ECT   OF  T AX4
T AX4                     NO
REG I ST .  T YPE
0 1                 NORMAL
REG I ST .  T YPE
0 1                     S I CS
GROUP  NO.
0 1                  
0 1
GROUP  NO.    
0 1                  
1 1
L  I M I T   D I G I T S
0 1
8
L  I M I T   D I G I T S
0 1
7
DEPT . 0 2            
0 2                     0 . 0 0
ENT ER [ 0 0 ] KEY
0 2                     0 . 0 0
     
PGM
0 . 0 0
1234567890123456
DEPT . 0 5         
0 5                      0 . 0 0
ENT ER  [ 0 0 ] KEY
0 5                     0 . 0 0
ENT ER T EXT      
0 5                     0 . 0 0
DEPT . 0 5         
0 5                       0 6 8
DR I NK   _              
0 5                       0 3 2
PR I CE     
0 5                       1 0 0
PR I CE     
0 5                       2 0 0
DEPT  ENT RY T YPE
0 1  
OPEN
DEPT  ENT RY T YPE
0 1  
OPEN
     
PGM
0 . 0 0
KEY ENTRY
OPERATER
NOTE
[PLU1]
  
PLU1 TEXT 
PLU CODE
->[00]
Message of “ENTER TEXT” is 
displayed.
Current PLU1 text is displayed.
Then the cursor is blinking. (
*
)
->066
Text code is inputted.
->[00]
If [00] key is entered and  input-
ted text is addressed.
Then the cursor is blinking.
->EER     
(_is set space)
text
->[ST]
Guidance message 
Current setting is displayed.
->200
Guidance message
->[ST]
Guidance message/PLU code
->02
Inputted DEPT no.
If you want to set PLU delete.
Please set 0.
->[ST]
Guidance message 
Current setting is displayed.
->[00]
->[00]
->[ST]
Guidance message
Current setting is displayed.
->[00]
->[00]
->[ST]
PLU2 TEXT / PLU CODE
RETURN TO 1’st STEP
->[TL]
PLU1 SET UP TERMINATE          
1234567890123456
PL U. 0 0 0 1
0 0 0 1                 0 . 0 0
ENT ER [ 0 0 ] KEY
0 0 0 1                 0 . 0 0
ENT ER T EXT      
0 0 0 1               0 . 0 0
PL U. 0 0 0 1      
0 0 0 1               0 8 0
PL U. 0 0 0 1      
0 0 0 1               0 6 6
BL U. 0 0 0 1      
0 0 0 1               0 7 6
BEER        
0 0 0 1                 0 3 2
PR I CE           
0 0 0 1                 1 0 0
PR I CE           
0 0 0 1                 2 0 0
ENT ER DEPT #  
0 0 0 1                 0 1
ENT ER DEPT #  
0 0 0 1                 0 2
S I GN
0 0 0 1                  ( + )
S I GN
0 0 0 1                  ( - )
S I GN
0 0 0 1                  ( + )
ENT ER PL U T YPE
0 0 0 1                  PL U
ENT ER PL U T YPE
0 0 0 1           SUBDEPT
ENT ER PL U T YPE
0 0 0 1                  PL U
PL U. 0 0 0 2   
0 0 0 2                 0 . 0 0
ENT ER [ 0 0 ] KEY
0 0 0 2                 0 . 0 0
     
PGM
0 . 0 0
XE-A303 (V)
PROGRAM MODE
2 – 17
<PROGRAMMING FOR (-)>
<PROGRAMMING FOR %>
<PROGRAMMING FOR EXCHANGE>
KEY ENTRY
OPERATER
NOTE
  [(-)]
  
(-) PROGRAMMING
Function no.
Function no.
->[00]
Function no.
Current (-) text is displayed.
Function no.
->[ST]
Message of “ENTER AMOUNT” 
is displayed.
->200
->[ST]
Guidance message
->[00]
->[ST]
Guidance message
->[00]
 
->[ST]
Guidance message
->[00]
 
->[ST]
Guidance message
Current setting is displayed.
->8
[ST]
 
KEY ENTRY
OPERATER
NOTE
[ %1 ]
% PROGRAMMING
->[00]
Message of “ENTER TEXT” is 
displayed.
Current % text is displayed.
Then the cursor is blinking.
->[ST]
Message of “ENTER RATE” is 
displayed.
->12.34
1234567890123456
 ( - )   PROGRAMM I NG
XX                    0 . 0 0
ENT ER  [ 0 0 ] KEY
XX                    0 . 0 0
ENT ER T EXT      
XX                    0 . 0 0
= ( = - = )            
XX                   
2 5 3
ENT ER AMOUNT
XX                   
0
ENT ER AMOUNT
XX                   
2 0 0
S I GN
XX
                 ( - )
S I GN
XX
                 ( + )
ENT RY  F OR   I T EM
XX      I T EM  ENABL E
ENT RY  F OR   I T EM
XX   IT EM  D I SABL E
E NT RY   F OR  S B T L
XX  SBT L  D I SABL E
E NT RY   F OR  S B T L
XX   SBT L  ENABL E
L  I M I T   D I G I T S
XX                          8
L  I M I T   D I G I T S
XX                          8
ENT ER [ T L  / NS] KEY
                        0 . 0 0
1234567890123456
%1 PROGRAMM I NG
XX                    0 . 0 0
ENT ER  [ 0 0 ] KEY
XX                    0 . 0 0
ENT ER T EXT      
XX                    0 . 0 0
=%= 1 =                  
XX                   
2 5 3
XX         
0 . 0 0
ENT ER RAT E
XX         
1 2 . 3 4
ENT ER RAT E
->[ST]
Guidance message
->[00]
->[ST]
Guidance message
->[00]
 
->[ST]
Guidance message
->[00]
 
->[ST]
Guidance message
Current setting is displayed.
->90.00
[ST]
  
% PROGRAMMING
KEY ENTRY
OPERATER
NOTE
[EX]
  
EXCHANGE PROGRAMMING
->[00]
Message of “ENTER TEXT” is 
displayed.
Current EXCH1 text is displayed.
Then the cursor is blinking.
->[ST]
Message of “ENTER EX RATE” 
is displayed.
->123.456789
->[ST]
Guidance message
->[00]
 
->[ST]
Guidance message
->[00]
 
->[ST]
Guidance message
KEY ENTRY
OPERATER
NOTE
1234567890123456
S I GN
XX
                 ( - )
S I GN
XX
                 ( + )
ENT RY  F OR   I T EM
XX      I T EM  ENABL E
ENT RY  F OR   I T EM
XX   IT EM  D I SABL E
E NT RY   F OR  S B T L
XX  SBT L  D I SABL E
E NT RY   F OR  S B T L
XX   SBT L  ENABL E
%  HA L O P ROG.   
XX                1 0 0 . 0 0
%  HA L O P ROG.   
XX               
9 0 . 0 0
%2 PROGRAMM I NG
XX                    0 . 0 0
ENT ER  [ 0 0 ] KEY
XX                    0 . 0 0
1234567890123456
XX         
0 . 0 0
E X CHA NGE  P ROG.
ENT ER  [ 0 0 ] KEY
XX                    0 . 0 0
ENT ER T EXT      
XX                    0 . 0 0
XX         
0 . 0 0
EXCH1    
XX            0 . 0 0 0 0 0 0
ENT ER EX RAT E
XX        1 2 3 . 4 5 6 7 8 9
ENT ER EX RAT E
X X       OP E N  E NA B L E
OP E N  RA T E   E NT RY
X X     OP E N  D I S A B L E
OP E N  RA T E   E NT RY
X X   P RE S E T   E NA B L E
P RE S E T   RA T E  
    P RE S E T   D I S A B L E
P RE S E T   RA T E  
XX                          2
T A B                
Page of 28
Display