DOWNLOAD Sharp XE-A303 (serv.man3) Service Manual ↓ Size: 674.59 KB | Pages: 28 in PDF or view online for FREE

Model
XE-A303 (serv.man3)
Pages
28
Size
674.59 KB
Type
PDF
Document
Service Manual
Brand
Device
ECR / XE-A303 Program Manual
File
xe-a303-sm3.pdf
Date

Sharp XE-A303 (serv.man3) Service Manual ▷ View online

CODE : 00Z
CONTENTS
Parts marked with "
!
" are important for maintaining the safety of the set. Be sure to replace these parts with specified
ones for maintaining the safety and performance of the set.
PROGRAMMING MANUAL
LEAD-FREE SOLDER MODEL
XEA303VPME
ELECTRONIC
CASH REGISTER
 MODEL
XE-A303
      
(For “V” version)
 LEAD-FREE SOLDER
CHAPTER 1. MASTER RESET AND PROGRAM RESET  . . . . . . 1 - 1
CHAPTER 2. PROGRAM MODE . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 1
CHAPTER 3. OP X/Z, X1/Z1, X2/Z2 MODE. . . . . . . . . . . . . . . . . . 3 - 1
XE-A303 (V)   LEAD-FREE SOLDER
 LEAD-FREE SOLDER
The PWB’ s of this model employs lead-free solder. The “LF” marks indicated on the PWB’s and the Service Manual mean “Lead-Free” solder. 
The alphabet following the LF mark shows the kind of lead-free solder. 
Example:
(1) NOTE FOR THE USE OF LEAD-FREE SOLDER THREAD
When repairing a lead-free solder PWB, use lead-free solder thread. Never use conventional lead solder thread, which may cause a breakdown or an accident. 
Since the melting point of lead-free solder thread is about 40°C higher than that of conventional lead solder thread, the use of the exclusive-use soldering iron is rec-
ommendable. 
(2) NOTE FOR SOLDERING WORK
Since the melting point of lead-free solder is about 220°C, which is about 40°C higher than that of conventional lead solder, and its soldering capacity is inferior to
conventional one, it is apt to keep the soldering iron in contact with the PWB for longer time. This may cause land separation or may exceed the heat-resistive tem-
perature of components. Use enough care to separate the soldering iron from the PWB when completion of soldering is confirmed. 
Since lead-free solder includes a greater quantity of tin, the iron tip may corrode easily. Turn ON/OFF the soldering iron power frequently.  
If different-kind solder remains on the soldering iron tip, it is melted together with lead-free solder. To avoid this, clean the soldering iron tip after com-
pletion of soldering work. 
If the soldering iron tip is discolored black during soldering work, clean
and file the tip with steel wool or a fine filer. 
5mm
Lead-Free
Solder composition 
code (Refer to the 
table at the right.)
<Solder composition code of lead-free solder> 
Solder composition
Sn-Ag-Cu
Sn-Ag-Bi
Sn-Ag-Bi-Cu
Sn-Zn-Bi
Sn-In-Ag-Bi
Sn-Cu-Ni
Sn-Ag-Sb
Bi-Sn-Ag-P
Bi-Sn-Ag
a
b
z
i
n
s
p
Solder composition code
a
XE-A303 (V)
MASTER RESET AND PROGRAM RESET
1 – 1
CHAPTER 1. MASTER RESET AND PROGRAM RESET
1. MASTER RESETTING
Master resetting clears the entire memory and resumes initial values.
Master resetting can be accomplished by using the following procedure:
Procedure:
1) Unplug the AC cord from the wall outlet, or set the mode switch to OFF position.
2) Set the mode switch to the PGM position.
3) While holding down both the JOURNAL FEED key and [CL] key, plugin the AC cord to the wall outlet.
The master reset can also be accomplished in the following case.
In case power failure occurs when the machine has no battery attached to it, the master reset operation is automatically performed after the power
has been plugined the AC cord to the wall outlet.
(This is because if power failure occurs with no battery attached to the machine, all the memories are lost and the machine does not work properly
after power recovery; this requires the master reset operation.)
2. PROGRAM RESETTING (INITIALIZATION)
This resetting resumes the initial program without clearing memory.
This resetting can be operated at below sequence in PGM mode.
Procedure:
1) Unplug the AC cord from the wall outlet.
2) Wait over 1 minute for discharging.
3) Set the mode switch to the PGM position.
4) While holding down the JOURNAL FEED key and RECEIPT FEED key, plugin the AC cord to the wall outlet.
Note: In case power failure occurs when the machine has no battery attached to it, the master reset operation is automatically performed after the
power has been restored.
XE-A303 (V)
PROGRAM MODE
2 – 1
CHAPTER 2. PROGRAM MODE
1. READING STORED PROGRAMS
The machine allows you to read every program stored in the PGM mode.
 
Key sequence for reading stored program
(
*
) PLU code range can be specified by entering the start and end numbers according to the following procedure.
When specifying a single time interval, PLU code, the start number has only to be entered.
 SAMPLE PRINTOUTS
1. PROGRAMMED DATA1 REPORT
(
*
1) (-) / % PROGRAM : ABC
(
*
2) MEDIA PROGRAM : ABC
Report name
Key sequence
Programmed data1 report
Programmed data2 report
Auto key programming report
Printer density report
DEPT data report
PLU data report (
*
)
TL
TL
TL
TL
TL
Start No.           
End No.
PLU
HEADER
DATE/TIME/CLERK CODE
MACHINE NO. /CC-NO. /CLERK NAME
FUNCTION NO. /TEXT/PROGRAM (
*
1)
AMOUNT WITH SIGN
FUNCTION NO. /TEXT/PROGRAM (
*
1)
HALO WITHOUT SIGN/RATE WITH SIGN
FUNCTION NO. /TEXT
FUNCTION NO. /TEXT/HALO
FUNCTION NO. /TEXT/PROGRAM (
*
2)
FUNCTION NO. /TEXT/PROGRAM (
*
3)
CURRENCY SYMBOL/RATE
008
008
008
008
008
002
999.999999
05/02/2001 12:34PM
123456#123456
F
01 (-) xxxxxx
F
02 %1xxxxxxxx
L100.00%
F
03 %2xxxxxxxx
L100.00%
F
04 NET1xxxx
F
05 DIFFERxxxxxx
 
 :
  
 :
F
26 
***
RAxxxxxxx
F
27 
***
POxxxxxxx
 
 :
F
32 CASHxxxx
F
33 CHECKxxxxxxx
F
34 CHECK2xxxxxx
F
35 CREDI T1xxxxx
F
36 CREDI T2xxxxx
F
37 EXCH1xxxxxxx
  ABCD
F
38 EXCH2xxxxxxx
 
 :
01
M.CLERK_____
007
-1000.00
000
-10.00%
000
-100.00%
9
9
 
 :
F
85              #
F
86 COPY
F
87 EX1 CHG
F
88 AMOUNT
SHARP
PRESENTS THE
XE-A303
SHARP
IS
THE BEST
#5
#6
#7
#8
#10
#11
#12
#13
#14
#20
#21
#22
#35 
T
1
T
2
T
T
4
 
C#01 ____________
C#02 xxxxxxxxxxxx
 
:
C#25 xxxxxxxxxxxx
00000000
00000000
00000000
0000
0000
0
00
00/00/0000
00:00
9999999.99
999999.99
999999.99
007 
10.0000%
123.45
4.0000%
0.10
-5.0000%
0.20
------
11
12
00
:
LOGO TEXT
(It is according with LOGO FORMAT.)
FUNCTION NO. /TEXT
TAX1 RATE
LOWER TAX LIMIT
TAX2 RATE
LOWER TAX LIMIT
TAX3
TAX4 ( g------ h:INHIBIT)
Clerk No./Clerk name/CODE
(JOB#5)   FUNCTION SELECT 
(JOB#6)   PRINT FUNCTION
(JOB#7)   RECEIPT PRINT FORMAT
(JOB#8)   EURO FUNCTIONS
(JOB#10) POWER SAVING PROGRAMMING 
(JOB#11) LOGO FORMAT
(JOB#12) EURO PROGRAMMING
(JOB#13) EURO CHANGING DATE (Printed by 
Date format)
(JOB#14) EURO CHANGING HOUR
(JOB#20) SENTINEL AMOUNT
(JOB#21) CHECK CASHING LIMITATION AMOUNT
(JOB#22) CHECK CHANGE LIMITATION AMOUNT
(JOB#35) USB Timeout time
VARIOUS PROGRAM 
Refer to the programming section about the 
data of each JOB.
FUNCTION NO. /TEXT
A: ENTRY FOR ITEM 
A
ENABLE
0
DISABLE
1
B: ENTRY FOR SBTL
B
ENABLE
0
DISABLE
1
C: LIMITATION DIGITS (for (-) key) = 0 to 7 (0 FIXED for [%n])
A: Footer print on Receipt
A
No
0
Yes
1
B: Entry of amount tenderd
B
Noncompulsory (Cash, check)/Inhibit (Credit)
0
Compulsory
1
C: LIMITATION DIGITS (0=INHIBIT) = 0 to 8
Page of 28
Display

Sharp XE-A303 (serv.man3) Service Manual ▷ Download

  • DOWNLOAD Sharp XE-A303 (serv.man3) Service Manual ↓ Size: 674.59 KB | Pages: 28 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sharp XE-A303 (serv.man3) in PDF for free, which will help you to disassemble, recover, fix and repair Sharp XE-A303 (serv.man3) ECR. Information contained in Sharp XE-A303 (serv.man3) Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.