Sharp UP-800 (serv.man26) Service Manual ▷ View online

UP-800F/810F (V)
SRV MODE PROGRAMMING (“3 IRC SET UP”)
4 – 3
[4 STD. WITH IRC]
DISPLAY: Setting screen
Select the item to be changed and press the ENTER key.
The setting content is described below.
[5 STAND ALONE]
Used to restore to a stand alone machine.
DISPLAY TEXT
CONTENTS
SELECT ITEM
MRS
IP ADDRESS 1
192
IP ADDRESS 2
168
IP ADDRESS 3
000
IP ADDRESS 4
Terminal No.
001-254
000
P UP
TERMINAL SETTING
SRV
1  SATELLITE
2  MASTER
3  BACKUP MASTER
4  STD. WITH IRC
5  STAND ALONE
PREV.
NEXT
LIST
P DOWN
UP-800F/810F (V)
SRV MODE PROGRAMMING (“4 DOWN LOAD”)
5 – 1
CHAPTER 5. SRV MODE PROGRAMMING (“4 DOWN LOAD”)
After IRC SETUP, using this setting procedure, download the setting
data from the master.
DISPLAY: SRV mode screen
Select DOWN LOAD METHOD item and press the ENTER key.
$
Select the item and press the ENTER key.
[1 ALL]
Download data from all the machines included in the master list.
[2 MACHINE SELECT]
Select the machine among the master list from which you want to down-
load data.
Select the machine and press the ENTER key.
$
The downloading of data is started.
P UP
SRV MODE
SRV
1  READING
2  SETTING
3  IRC SET UP
4  DOWN LOAD
5  DIAGNOSTIC 
6  PRINTER
7  SD CARD MODE
PREV.
NEXT
LIST
P DOWN
UP-800F/810F (V)
SRV MODE PROGRAMMING (“5 DIAGNOSTICS”)
6 – 1
CHAPTER 6. SRV MODE PROGRAMMING (“5 DIAGNOSTICS”)
Execute the test program.
Fore more information, see the Service Manual.
DISPLAY: SRV mode screen
P UP
SRV MODE
SRV
1  READING
2  SETTING
3  IRC SET UP
4  DOWN LOAD
5  DIAGNOSTIC 
6  PRINTER
7  SD CARD MODE
PREV.
NEXT
LIST
P DOWN
UP-800F/810F (V)
SRV MODE PROGRAMMING (“6 PRINTER”)
7 – 1
CHAPTER 7. SRV MODE PROGRAMMING (“6 PRINTER”)
EURO SYMBOL
* If above printer is corresponded with EURO symbol, then please
change symbol code for EURO symbol (213).
Kind of printer
MRS default code
TM-T88 (3) / T88 (4)
032
TM-U220 / 230
032
TM-U295
032
TM-T88 (3)(4) + LOGO
032