47
For each PLU
For a range
of PLUs
Alphanumeric characters  
You can program a maximum of 16 characters (item label) for each PLU or subdepartment.  (However, the
default setting is for a 12-character label.) Select the characters you want to program, referring to section “2
How to program alphanumeric characters” in chapter “PRIOR TO PROGRAMMING”.
Label 
programmed 
for PLU code 1
2214 
. ≈
MILK
:
;
Print
Key operation
Example
2214
.
:
;
PLU code
To program spaces
Character keys 
(max. 16 digits)
c
Procedure
2214
PGM 2
PLU range
Taxable 1
2232 
. ≈
11 
20 
0000001 
:
;
Print
Key operation
Taxable 1
2211 
. ≈
0000001 
:
0000000 
:
;
Print
Key operation
Example
48
Assigning of PLUs to commission groups  
You can assign PLUs (or subdepartments) to commission groups.
For each PLU
For a range of PLUs
*1,2,3 :  1 through 999999
*A
:  Commission group 0-9 (0=no commission)
For each PLU
For a range
of PLUs
Commission
group number
PLU range
2235 
. ≈
12 
14 
1
:
;
Print
Key operation
Commission
group number
2215 
. ≈
:
;
Print
Key operation
Example
2235
.
:
;
* 3
To apply the current setting of start 
PLU code to PLUs within the range
The current 
setting 
is displayed.
* 2
Start PLU code
End PLU code
* A
2215
.
:
;
* 1
To keep the current setting
To program for the following PLU
The current 
setting 
is displayed.
PLU code
c
* A
Procedure
2235
2215
PGM 2
49
Link PLU  
• To program this function, please consult your dealer.
• PLU codes must have already been defined.
Direct PLU key positioning  
You can assign a PLU code to each key position.  PLUs may be selected for the number of direct PLU keys and
their positions.  For key number positions, refer to section “2 Standard key number layout” in the chapter
“KEYBOARD”.
* The key number placement is determined by your local Authorized SHARP Dealer.
PLU code
Key no.
2219 
. ≈
16 
:
;
Print
Key operation
Example
2219
.
:
;
Key no. 
(1 through 68)
PLU code
To program for the following key number
To program for the key number other than the following key number
Cancellation
*
Procedure
2219
PGM 2
Linked 
PLU code
2220 
. ≈
21 
25 
:
26 
:
27 
:
;
Print
Key operation
Example
Note
2220
.
:
;
PLU code
Linked PLU code
Cancellation
To repeat up to 5 times
Procedure
2220
PGM 2
EAN or UPC code
Your machine can transact the following codes:
• UPC-A (Number system character: 0, 2, 3, 4)       • UPC-E      
• EAN-8       • EAN-13       • Internal code EAN-8/EAN-13
For the codes used in-store marking, there are two types of PLU type (treated as a code like PLU code) and
Non-PLU type (price/quantity information is included in the code).
When a code is non-PLU type, the price/quantity in the code is read for sales entry (in case of quantity, “quantity
multiplys preset unit price” is processed to obtain price.)
UPC-A
• Number system character: 0 <used in the source marking>
• Number system character: 3 <used as NDC or HRI>
For entry, a full 12 digits number or 11 digits number (omitting the
check digits) must be entered.
• Number system character: 2 <In-store marking Non-PLU type>
You can program the format by the job #2025.
• Number system character: 4 <In-store marking PLU type>
For entry, a full 12 digits number, 11 digits number (omitting the
check digit), or a leading zero plus 12 digits number must be
entered.(Any numbers are allowed for the digits marked with *,
and on the receipt/journal, non-PLU type code is printed like 2020008**** (****: price information).)
UPC-E
• UPC-E is a zero-suppressed version of UPC-A that conforms to
the UPC-E Standards.  This code is used for marking small
package.
For entry, a 6 digits number or a leading zero plus 6 digits number
must be entered.
EAN-8
• Ordinary EAN-8 code (flag: neither 0 nor 2) <used in the source marking>
For entry, a full 8 digits number must be entered.
• Internal code (flag 2) <in-store marking non-PLU short type>
Program the format by the job #2025.
• Internal code (flag 0) <in-store marking PLU short type>
For entry, a full 8 digits number must be entered.  On the
receipt/journal, non-PLU type code is printed like 208**** (****:
price/quantity information)
European Article Number (EAN) or Universal Product Code (UPC) programming
6
50
0
C
D
Maker code
Number system character
Item code
Check digit
3
C
D
NCD (or HRI) format
2
*
*
*
*
*
C
D
Item code
Price
Price check digit
4
C
D
(Free code)
C
D
Maker code
Item code
Nation code
2
C
D
(Free format)
0
C
D
(Free code)
Program the format by the job#2025.