2-2. G.A (MPCA7)
1) Pin configuration
GATE ARRAY (LZ9AH39)
MPCA7
Fig. 2-3
1
RF
2
JF
3
PCUT
4
FCUT
5
VF
6
STAMP
7
SLF
8
SLRS
9
SLMTD
10
RES
11
TRG
12
TRG
13
POFF
14
INT1
15
HTS1
16
SCK1
17
STH1
18
NU
19
NU
20
VCC
21
GND
22
NU
23
VRESC
24
SLTMG
25
SLRST
26
AS
27
RD
28
WR
29
PHAI
30
SDT7
31
SDT6
32
SDT5
33
GND
34
SDT4
35
SDT3
36
SDT2
37
SDT1
38
D0
39
D1
40
D2
16
0
N
U
159
D
O
T
E
N
158
T
W
A
IT
157
N
U
15
6
N
U
155
N
U
154
N
U
153
N
U
15
2
S
TH
2
151
S
C
K
2
150
H
T
S
2
149
S
L
M
T
R
14
8
S
L
M
T
S
147
S
L
MT
D
146
R
JM
T
R
145
R
A
S
3
14
4
N
U
14
3
G
N
D
142
V
C
C
141
A
S
K
R
X
140
N
U
13
9
N
U
138
N
U
137
R
JM
T
D
136
R
JM
T
S
13
5
D
T
5
134
D
T
6
133
D
T
7
132
G
N
D
13
1
D
T
1
130
D
T
2
129
D
T
3
128
D
T
4
12
7
R
JT
MG
1
2
6
RJ
RST
125
R
A
S
1
124
R
A
S
2
12
3
R
O
S
2
12
2
R
O
S
1
121
O
P
T
C
S
41
D3
42
GND
43
D4
44
D5
45
D6
46
D7
47
SSPRQ
48
RESET
49
INT
2
50
IN
T
3
51
RXDI
52
TX
D
I
53
SC
K
I
54
IR
Q
0
55
A0
56
A1
57
A2
58
A3
59
A4
60
A5
61
GN
D
62
VCC
63
A6
64
A7
65
A8
66
A9
67
A1
0
68
A1
1
69
A1
2
70
A1
3
71
A1
4
72
A1
5
73
A1
6
74
A1
7
75
A1
8
76
A1
9
77
A2
0
78
A2
1
79
A2
2
80
NU
120
EXINT0
119
EXINT1
118
EXINT2
117
EXINT3
116
WRO
115
RDO
114
RA15
113
RA16
112
GND
111
RA17
110
RA18
109
EXWAIT
108
WAIT
107
NU
106
MCR1
105
NU
104
DAX1
103
RCKX
102
IRRX
101
GND
100
VCC
99
UATX
98
UARX
97
UASCK
96
IRTX
95
RCO
94
NU
93
NU
92
NU
91
NU
90
MA15
89
TEST
88
MD0
87
MD1
86
IPLON
85
INT4
84
PRST
83
PTMG
82
TRGI
81
A23
4 – 5
2) Block diagram
Fig. 2-4
MTD
MTD
RJMTR
SLMTD
SLMTS
SLMTR
SLMTD
TXDI
SCKI
RXDI
HTS1
SCK1
STH1
HTS2
SCK2
STH2
ROS1
ROS2
RAS1
RAS2
RAS3
OPTCS
AS
RD
WR
RDO
WRO
Φ
RESET
RES
VRESC
POFF
MD0
MD1
WAIT
RJRST
SLRST
*PRST
RJTMG
SLTMG
PTMG
INT4
INT1
INT2
INT3
EXINT0
EXINT1
EXINT2
EXINT3
SD
T1
~7
DT
1
~
9
TEST
IRQ0
A23~A0
SSPRQ
SL
F
SL
R
S
VF
RF
JF
F
CUT
PC
U
T
STAM
P
TR
G
I
TR
G
TR
G
DO
T
E
N
IRLON
D0~D7
Φ
Address decode
 External CS
 Internal CS
RASEL
Image
control
SSP comparison register
BAR.
Buffer
Read/write
control
Divider
CHS 
serial select
Multiplexer
WAIT
control
CAPS
select
Print gate
Print pulse control
Print mode PMD
INTO
control
Printer control port
Motor
drive
* Output selection with CAPS.
   PRST/PTMG.
EXWAIT
I/R Control
IRTX
IRRX
RCI
ASKRX
4 – 6
3) Pin description
Pin
No.
Signal
name
In/
Out
Function
1
RF
Out
Receipt side paper feed solenoid (NU)
2
JF
Out
Journal side paper feed solenoid (NU)
3
PCUT
Out
Printer partial cut signal (NU)
4
FCUT
Out
Printer auto cut signal (NU)
5
VF
Out
Multi line validation paper feed (NU)
6
STAMP
Out
Printer stamp signal (NU)
7
SLFS
Out
Slip printer paper feed singnal (NU)
8
SLRS
Out
Slip printer release signal (NU)
9
SLMTD
Out
Slip printer motor drive signal (NU)
10
RES
Out
Peripheral output reset
11
TRG
Out
Dot head trigger signal (NU)
12
TRG
Out
Dot head trigger signal (NU)
13
POFF
In
Power off signal input
14
INT1
In
(NU)
15
HTS1
Out
8 bit serial port output (for CKDC8)
16
SCK1
Out
Serial port shift clock output (for CKDC8)
17
STH1
In
8 bit serial port input (for CKDC8)
18
RAS VZ
Chip select (NU)
19
Nu
20
VCC
+5V
21
GND
GND
22
INTMCR
Interrupt (NU)
23
VRESC
Out
Turns active when reset and power
down is met
24
SLTMG
In
Slip printer timing signal (NU)
25
SLRST
In
Slip printer reset signal (NU)
26
AS
In
Address strobe
27
RD
In
Read strobe
28
WR
In
Write strobe
29
φ
In
(
φ
) System clock (9.83 MHz)
30
SDT7
Out
Slip printer printhead drive signal (dot7)
(NU)
31
SDT6
Out
Slip printer printhead drive signal (dot6)
(NU)
32
SDT5
Out
Slip printer printhead drive signal (dot5)
(NU)
33
GND
GND
34
SDT4
Out
Slip printer printhead drive signal (dot4)
(NU)
35
SDT3
Out
Slip printer printhead drive signal (dot3)
(NU)
36
SDT2
Out
Slip printer printhead drive signal (dot2)
(NU)
37
SDT1
Out
Slip printer printhead drive signal (dot1)
(NU)
38
D0
I/O
Data bus 0
39
D1
I/O
Data bus 1
40
D2
I/O
Data bus 2
41
D3
I/O
Data bus 3
42
GND
GND
43
D4
I/O
Data bus 4
44
D5
I/O
Data bus 5
45
D6
I/O
Data bus 6
46
D7
I/O
Data bus 7
47
SPRQ
Out
SSP interrupt request to CPU
48
RESET
In
MPCA reset
49
SHEN
In
Shift enable from CKDC8
50
INT3
In
Interrupt signal (Nu)
Pin
No.
Signal
name
In/
Out
Function
51
RXD2
Out
8 bit serial port output to CPU
52
TXD2
In
8 bit serial port input from CPU
53
SCK2
In
Serial port shift clock input from CPU.
54
IRQ0
Out
Interrupt request to CPU
55
A0
In
Address bus 0
56
A1
In
Address bus 1
57
A2
In
Address bus 2
58
A3
In
Address bus 3
59
A4
In
Address bus 4
60
A5
In
Address bus 5
61
GND
GND
62
VCC
+5V
63
A6
In
Address bus 6
64
A7
In
Address bus 7
65
A8
In
Address bus 8
66
A9
In
Address bus 9
67
A10
In
Address bus 10
68
A11
In
Address bus 11
69
A12
In
Address bus 12
70
A13
In
Address bus 13
71
A14
In
Address bus 14
72
A15
In
Address bus 15
73
A16
In
Address bus 16
74
A17
In
Address bus 17
75
A18
In
Address bus 18
76
A19
In
Address bus 19
77
A20
In
Address bus 20
78
A21
In
Address bus 21
79
A22
In
Address bus 22
80
LCDC
LCD CS (NU)
81
A23
In
Address bus 23
82
TRGI
In
Dot pulse control/drive signal (NU: GND)
83
PTMG
Out
Printer timing signal to CPU
84
PRST
Out
Printer reset signal to CPU
85
RDY
In
Ready from FMC unit
86
IPLON
In
To option connector (NU) +5V
87
MD1
In
Mode select input (GND)
88
MD0
In
Mode select input (GND)
89
TEST
In
+5V
90
MA15
Image address 15
91
MA18
Nu
92
MA19
Nu
93
RCVRDY1
Nu:  +5V
94
RCVRDY2
Nu:  +5V
95
RC0
Remote control encord signal for CPU
(NU)
96
IRTX
I/R output for LED (NU)
97
UASCK
I/R serial data shift clock (NU)
98
UARX
I/R serial data for CPU (NU)
99
UATX
I/R serial data from CPU (NU) +5V
100
VCC
+5V
101
GND
GND
102
IRRX
I/R input from I/R unit (NU) +5V
103
RCI
I/R input from I/R unit (NU) +5V
104
DAX1
System clock (NU)
105
DAX2
Nu
106
MCR1
Nu
4 – 7
Pin
No.
Signal
name
In/
Out
Function
107
MCR2
Nu
108
WAIT
Out
Wait request signal
109
EXWAIT
In
External wait control input signal (NU)
+5V
110
RA18
Out
Nu
111
RA17
Out
Nu
112
GND
GND
113
RA16
Out
Nu
114
RA15
Out
Nu
115
RDO
Out
Expansion RD signal
Option
116
WRO
Out
Expansion WR signal
117
EXINT3
In
RS232C /CD interrupt  
118
EXINT2
In
Option PWB (PULL UP)
119
EXINT1
In
RS232C /CI interrupt
120
EXINT0
In
Option PWB (PULL UP)
121
OPTCS
Out
Chip select base signal for expansion
option
122
ROS1
Out
ROM 1 chip select signal
123
ROS2
Out
ROM 2 chip select signal (NU)
124
RAS2
Out
RAM 2 chip select signal
125
RAS1
Out
RAM 1 chip select signal
126
RJRST
In
Printer reset signal
127
RJTMG
In
FOR TPRC (NU)  +5V
128
DT4
Out
Printer dot signal 4 (NU)
129
DT3
Out
Printer dot signal 3 (NU)
130
DT2
Out
Printer dot signal 2 (NU)
131
DT1
Out
Printer dot signal 1 (NU)
132
GND
GND
133
DT7
Out
Printer dot signal 7 (NU)
134
DT6
Out
Printer dot signal 6 (NU)
135
DT5
Out
Printer dot signal 5 (NU)
136
MTD
Out
Printer motor drive signal (NU)
137
MTD
Out
Printer motor drive signal (NU)
138
DOT9
Out
Printer dot signal 9 (NU)
139
DOT8
Out
Printer dot signal 8 (NU)
140
SYNC
Nu (+5V)
141
ASKRX
I/R input from I/R unit (NU) Pull-up
142
VCC
+5V
143
GND
GND
144
Nu
145
RAS3
Out
Nu
146
RJMTR
In
Printer motor lock detection signal (NU)
GND
147
SLMTD
Out
Nu
148
SLMTS
Out
Nu
149
SLMTR
In
GND
150
HTS2
Out
Serial output to FMC unit
151
SCK2
Out
Serial clock to FMC unit
152
STH2
In
Serial input to FMC unit
153
Nu
154
Nu
155
Nu
156
Nu
157
Nu
158
LCDWT
IN
TPRC wait signal
159
DOTEN
Out
Dot drive enable signal (Nu)
160
RASP
Nu
2-3. CKDC8
1) Pin configulation
2) Pin assignment (CKDC8)
Pin
No.
SYMBOL
SIGNAL
NAME
IN/
OUT
FUNCTION
1
DP
DP
OUT DISPLAY SEGMENT Dp
2
A
SA
OUT DISPLAY SEGMENT a
3
B
SB
OUT DISPLAY SEGMENT b
4
C
SC
OUT DISPLAY SEGMENT c
5
D
SD
OUT DISPLAY SEGMENT d
6
E
SE
OUT DISPLAY SEGMENT e
7
F
SF
OUT DISPLAY SEGMENT f
8
G
SG
OUT DISPLAY SEGMENT g
9
VSS0
GND
GND
10
VDD0
VDD
VDD
11
KR4
KR4
IN
KEY RETURN 4
12
KR10
KR10
IN
KEY RETURN (feed clerk
MRS sw)
13
KR11
KR11
IN
KEY RETURN (MODE sw)
14
KR8
NU
IN
GND
15
HTS
HTS
IN
16
STH
STH
OUT
17
/SCK
/SCK
IN
SHIFT CLOCK
18
ST0
ST0
OUT KEY STROBE 0
19
ST1
ST1
OUT KEY STROBE 1
20
ST2
ST2
OUT KEY STROBE 2
21
ST3
ST3
OUT KEY STROBE 3
22
ST4
ST4
OUT KEY STROBE 4
23
ST5
ST5
OUT KEY STROBE 5
24
VDD1
VDD
VDD
25
AXSS
GND
GND
26
KR9
NU
GND
27
KR0
KR0
IN
KEY RETURN 0
28
KR1
KR1
IN
KEY RETURN 1
29
KR2
KR2
IN
KEY RETURN 2
30
KR3
KR3
IN
KEY RETURN 3
31
KR5
KR5
IN
KEY RETURN 5
NU
NU
G10
G9
G8
G7
G6
G5
G4
G3
G2
G1
BUZ
/POFF
NU
ST8
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
DP
SA
SB
SC
SD
SE
SF
SG
GND
VDD
KR4
KR10
KR11
NU
HTS
STH
48
47
46
45
44
43
42
41
40
39
38
37
36
35
34
33
ST7
ST6
/RESETS
/SHEN
ERC
LDRQ
GND
GND
/RES0
VDD
GND
KR7
64
63
62
61
60
59
58
57
56
55
54
53
52
51
50
49
/SCK
ST0
ST1
ST2
ST3
ST4
ST5
VDD
GN
D
NU
KR0
KR1
KR2
KR3
KR5
KR6
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
CKDC8
4 – 8
Page of 42