DOWNLOAD Sharp ER-A411 / ER-A421 (serv.man5) Service Manual ↓ Size: 9.33 MB | Pages: 127 in PDF or view online for FREE

Model
ER-A411 ER-A421 (serv.man5)
Pages
127
Size
9.33 MB
Type
PDF
Document
User Manual / Operation Manual
Brand
Device
ECR / ER-A411 421 Instruction Manual
File
er-a411-er-a421-sm5.pdf
Date

Sharp ER-A411 / ER-A421 (serv.man5) User Manual / Operation Manual ▷ View online

41
 
PLU/EAN information inquiry (view) function
This function displays the information data such as the unit price and food ingredients of a PLU/EAN item 
(view mode).
NOTE
To use this function on ER-A421, consult your authorized SHARP dealer.
 
Procedure
Numeric entry
(Q'ty 
@
 )
Price/PLU 
level shift
Scan EAN code
*
1
 The unit price is displayed. 
*
2
*
3
Direct PLU key
For refund entry
Unit price
(MGR mode)
*
4
AMT
AMT
EAN code
PLU code
U
l
f
f
Z
f
U
*1: The unit price is displayed when the PLU/EAN code is entered.
*2: Press the 
l
 key to cancel the view mode.
*3: Press the 
 key to register the displayed PLU/EAN item.
*4: You can change the unit price temporarily in the MGR mode. The unit price programmed in the PGM 
mode is not changed. You need to make a manager code entry to enter the MGR mode before the 
transaction.
Example
Key operation
Display
 
Z
20 
U
42
 
EAN price change function
NOTE
To use this function, consult your authorized SHARP dealer.
You can use this function when you need to change the unit price or associated department of an EAN item 
in REG/MGR mode.
There are two methods for change:
• Price change mode
You can change the preset price and/or the associated department of an EAN item without entering PGM 
mode.
• Changing price during a transaction
When you has found a wrong EAN price and/or associated department upon transaction, you can correct 
them at the time of transaction. With the entry of new price and/or associated department, the preset price 
and/or associated department is automatically changed to the new price and/or associated department.
NOTE
For the Non-PLU type EAN codes having price info. and press codes, the prices in the codes 
have the priority over the preset prices. So, for these codes, a changed price is valid only when 
price change is executed.
Procedure
Price change mode
EAN code
Department key
Scan EAN code
Price entry window is displayed.
To cancel the mode 
To keep the price
Unit price
To change the associated dept. 
using the dept. code entry key
To change the associated dept. directly 
by depressing the corresponding key
U
c
t
Dept. code
Selection from 
the dept. list
s
E
E
Changing price during a transaction
EAN code
Scan EAN code
To cancel
To keep the price
Unit price
Price entry window is displayed.
U
c
E
t
Department key
To change the associated dept. 
using the dept. code entry key
To change the associated dept. directly 
by depressing the corresponding key
Dept. code
Selection from 
the dept. list
s
E
NOTE
The 
A
 key can be used instead of the 
E
 key.
43
Example
Price change mode
Key operation
Print
t
5087654321106 
U
600 
E
Example
Changing a price during a transaction
Key operation
Print
5087654321106 
U
t
600 
E
A
NOTE
• When an undefi ned code is entered in the price change mode, the register goes to an error 
status.
• When you press the 
t
 key during a transaction, the EAN entry is voided of the 1st depression 
of the 
t
 key, then you are allowed to enter a correct price and/or associated department.
• When an associated department is changed, the item label for the department will be also 
changed automatically to the item label of new associated department.
• For the repeat entry, use the 
 key.
 
Set PLU/EAN entries
Operation is the same as that for normal PLU/EAN entries.
When a set PLU/EAN is entered, the labels of those PLUs tied to the set PLU/EAN are printed automatically.
Example
Key operation
Print
12 
U
A
Tied 
PLUs
44
 
PLU level shift (for direct PLUs)
NOTE
To use this function on ER-A411, consult your authorized SHARP dealer.
This shift can double or triple the number of direct PLUs on your register without adding additional direct PLU 
keys. You can use direct PLUs in three levels by utilizing the 
 key or PLU level shift keys 
\
 through 
]
.
Level key shifts the PLU level from the other two to the required level. (The normal level is the level 1.)
You must program your machine in the PGM2 mode to select one of the two PLU level shift modes — 
automatic return mode* and lock shift mode** — and decide whether to allow PLU level shift in both the 
REG and MGR modes or in the MGR mode alone.
*  The automatic return mode automatically shifts the PLU level back to level 1 after pressing a direct PLU 
key or fi nalizing each transaction (either can be selected in the PGM2 mode).
** The lock shift mode holds the current PLU level until depression of a PLU level shift key.
Automatic return mode (for PLU levels)
If your register has been programmed for PLU level in the automatic return mode, press a desired PLU level 
shift key before a numeric entry.
Procedure
Direct PLU
(Finalization)
(Q’ty,         ) 
Numeric entry
Direct PLU
Return to level 1
(Q’ty,         ) 
Numeric entry
(Returning every item entry)
(Returning every transaction)
n: PLU shift no. (1 through 3)
through
n
L3
L1
LEVEL
#
through
n
L3
L1
LEVEL
#
NOTE
When you use the FF method, you need not press the 
@
 key for multiplication entries.
Lock shift mode (for PLU levels)
If your register has been programmed for PLU level in the lock shift mode, press a desired PLU level shift 
key before a numeric entry.
Procedure  
n: PLU shift no. (1 through 3)
Direct PLU
Stay in the current level
(Q’ty,         ) 
Numeric entry
through
n
L3
L1
LEVEL
#
NOTE
When you use the FF method, you need not press the 
@
 key for multiplication entries.
Page of 127
Display

Click on the first or last page to see other ER-A411 / ER-A421 (serv.man5) service manuals if exist.