Sharp ER-A411 / ER-A421 (serv.man3) Service Manual ▷ View online
SRV MODE
9-7
3.SETTING
3-1 DEVICE CONFIG
Refer to the DEVICE CONFIG in PGM SETTING (Page 8-58).
3-2 SYSTEM PRESET
Euro fiscal restriction.
Some programming items are restricted. These programming items are indicated with highlighted.
Refer to following chart about treatment of each item.
Refer to following chart about treatment of each item.
Indication of Fiscal column
(Fixed)
This item cannot be changed and fixed value is applied.
Report print will be done.
Report print will be done.
(Default)
This item can be changed. But, default value is changed when the machine entered into fiscal mode.
(Invalid)
This function is prohibited. Therefore, this item cannot be changed and ignored, but other items are selectable.
<JOB #901>
Programming Item
Data
Fiscal
A411
A421
SWE
NLD
NOR
DEU
A
4:
0: (fixed)
0
0
2:
0: (fixed)
1:
0: (fixed)
B
TAX system
5: Auto VAT1-3 & Auto TAX 4-6
(Inhibit)
(Inhibit)
1
1
4: Manual TAX1-6
(Inhibit)
(inhibit)
(inhibit)
3: Manual VAT1
(Inhibit)
(inhibit)
(inhibit)
2: Manual VAT1-6
(Inhibit)
(inhibit)
(inhibit)
1: Auto VAT1-6
(Default)
(Default)
(Default)
0: Auto TAX1-6
C
Rounding system
3: 100
(Default)
(Default)
0
0
2: 50
1: 25
0: Normal
(Fixed)
(Fixed)
D
Tabulation
(4-9 : none)
2
2
3: 3digits
2: 2digits
(Fixed)
(Fixed)
(Fixed)
1: 1digit
SRV MODE
9-8
<JOB #902>
Programming Item
Data
Fiscal
A411
A421
A
4:
0: (fixed)
0
0
2:
0: (fixed)
1:
0: (fixed)
B
4:
0: (fixed)
0
0
2:
0: (fixed)
1:
0: (fixed)
C
4:
0: (fixed)
0
0
Clerk report format
2: Format3 (Cashier + Clerk for Retail)
1: Format2 (Clerk only for Retail)
0: Format1 (Clerk only for Hospitality)
1: Format2 (Clerk only for Retail)
0: Format1 (Clerk only for Hospitality)
D
4:
0: (fixed)
0
0
Country selection
2: Others
0: EU
0: EU
1:
0: (fixed)
<JOB #903>
Programming Item
Data
Fiscal
A411 A421
A
(1-9 : none)
0: (fixed)
0: (fixed)
0
0
B
4:
0: (fixed)
0
0
2:
0: (fixed)
1:
0: (fixed)
C
4:
0: (fixed)
0
0
2:
0: (fixed)
1:
0: (fixed)
D
(1-9 : none)
0: (fixed)
0: (fixed)
0
0
SRV MODE
9-9
<JOB #904>
Programming Item
Data
Fiscal
A411 A421
A
Printing of date
4: No
0
0
0: Yes
(Fixed)
2:
0: (fixed)
1:
0: (fixed)
B
Printing of the consecutive number
4: No
0
0
0: Yes
(Fixed)
2:
0: (fixed)
1:
0: (fixed)
C
4:
0: (fixed)
0
0
2:
0: (fixed)
1:
0: (fixed)
D
4:
0: (fixed)
0
0
2:
0: (fixed)
1:
0: (fixed)
<JOB #905>
Programming Item
Data
Fiscal
A411 A421
A
4:
0: (fixed)
0
0
2:
0: (fixed)
1:
0: (fixed)
B
Tax printing when taxable subtotal is zero.
4: Yes
0: No
0: No
1
1
2:
0: (fixed)
Tax printing when tax is zero.
1: No
0: Yes
0: Yes
C
4:
0: (fixed)
0
0
Printing of rounding amount (for SCA)
2: Yes
0: No
0: No
Printing of split pricing entry
1: SCA format
0: Normal
0: Normal
D
(1-9 : none)
0: (fixed)
0: (fixed)
0
0
SRV MODE
9-10
< JOB # 906 >
Programming Item
Data
Fiscal
A411 A421
SWE
NLD
NOR
DEU
A
Printing of PLU codes
4: Yes
0: No
0: No
0
0
Entry which makes the PLU/EAN
stock counters negative.
stock counters negative.
2: Inhibited
1: Operation allowed despite error
1: Operation allowed despite error
message
0: Allowed unconditionally
B
Bottle Return function
4: Enable
0: Disable
0: Disable
0
0
HASH setting
2: Enable
0: Disable
(Default)
1:
0: (fixed)
C
Count method of split pricing entry 4: Package
0: Quantity
0
3
Multiplication entry
3: FFx (FF sequence + Split pricing)
2: Split pricing
1: Successive multiplication
0: Multiplication only
2: Split pricing
1: Successive multiplication
0: Multiplication only
D
PLU/EAN price lookup at refund
entry.
entry.
4: No
0: Yes
0: Yes
1
1
Presetting of consecutive no.
2: No
(Fixed)
(Fixed)
(Fixed)
(Fixed)
0: Yes
Fractional quantity
1: Yes (3 digit decimal places)
0: No
(Default)
<JOB #907>
0Programming Item
Data
Fiscal
A411 A421
SWE
NLD
NOR
DEU
A
4:
0: (fixed)
0
0
Starting cash memory input
(available for NLD, NOR, DEU)
(available for NLD, NOR, DEU)
2: Compulsory for ALL
clerks (cashiers)(*)
(Fixed)
0: Non-compulsory
(Fixed)
(Default)
(Default)
B
4:
0: (fixed)
1
1
EAN code printing on journal
2: No
0: Yes
0: Yes
EAN code printing on receipt
1: No
0: Yes
0: Yes
C
In case of CCD compulsory (#988-D),
X report before CCD entry
X report before CCD entry
4: Enable
0: Disable
0: Disable
1
1
Locking of REG mode entry after
individual clerk (cashier) resetting(*)
individual clerk (cashier) resetting(*)
2: Enable
0: Disable
0: Disable
Minus Department/PLU
1: Enable
0: Disable
0: Disable
D
Z-counter print for PLU, Hourly, Clerk,
Daily Net, GLU, Cashier
Daily Net, GLU, Cashier
4: No
4
4
0: Yes
(Fixed)
(1-3 : none)
0: (fixed)
0: (fixed)
(*) In case of Cashier + Clerk system, the function acts for cashier not for clerk.
Click on the first or last page to see other ER-A411 / ER-A421 (serv.man3) service manuals if exist.