– 13 –
XL-HP600E
TEST MODE
 Setting the test mode
 Any one of test mode can be set by pressing several keys as follows.
 <X-BASS> + <CD> + <ON/STAND-BY> TEST: CD operation test.
Function: -CD test mode.
-Enter test 4 mode.
C  D       T  E  S  T
OPEN/CLOSE operation is using manual.
<< 
 >>, << 
 >> buttons make pick's slide possible.
Do TOC IL. Do normal play.
When these following key is input
into PLAY key, track number  can
be appoint directly.
<<PLAY>> key input.
<<MEMORY>> key input.
<<
 1>> key: Track 4
<<
 2>> key: Track 9
<<
 3>> key: Track 15
<<STOP>> key input.
STOP
Laser ON.
<<MEMORY>> key input.
Tracking OFF play at that
specific point.
<<MEMORY>> key input.
Tracking ON play from
that specific point.
<<STOP>> key input.
STOP
IL isn't done
VOL — Last memory
BAL — CENTER
P.GEQ — FLAT
X-BASS — OFF
To cancel : Power OFF
Sliding the PICKUP with
<< 
 >>, << 
 >> button
must only be in STOP mode.
<<MEMORY>>
key input.
Adjustment result
automatically will
display as below.
for each 2 sec :
a) "FOFF_XX"
b) "TOFF_XX"
c) "TBAL_XX"
d) "TGAN_XX"
f) "FGAN_XX"
g) "RFLS_XX"
explanation:
a) Focus off set
= "FOFF_XX"
b) Tracking off set
= "TOFF_XX"
c) Tracking balance
= "TBAL_XX"
d) Tracking Gain
= "TGAN_XX"
f)
Focus Gain
= "FGAN_XX"
g) RF level shift
= "RFLS_XX"
Adjustment result automatically will
display as below for each 2 sec :
a) "FOFF_XX"
b) "TOFF_XX"
c) "TBAL_XX"
d) "TGAN_XX"
f) "FGAN_XX"
g) "RFLS_XX"
<<MEMORY>> key input.
XL-HP600E
– 14 –
Standard Specification of Stereo System Error Message Display Contents
                     Error Contents
DISPLAY
                               Notes
CD
Pickup Mechanism Error.
'ER-CD**'
01: PU-IN SW Detection NG.
CD Changer Mechanism Error.
'ER-CD**'
10: Changer Error.
 (*)
11: Initial Error.
CD DSP Communication Error
'ER-CD**'
31: DSP COMMUNICATION ERROR
Focus Not Match.
'NO DISC'
TUN
PLL Unlock.
 
FM 
  
87.50
 
  MHz
PLL Unlock.
(*) CHECKING:
If CD changer mechanism error is detected, 'CHECKING' will be display instead of 'ER-CD**' display 'ER-CD**' will only be display
when CD changer mechanism error had been detected for the 5 th times.
Speaker abnormal detection and +B PROTECTION display
In case speaker abnormal detection or +B PROTECTION had occurred, it can be check by pressing 'POWER', 'VIDEO' and 'X-
BASS' key twice. Display will show "S** B**". S is referring to speaker abnormal detection and B is referring to +B PROTECTION.
** is in hex valve.
+B PROTECTION is condition when irregular process occur on power supply line.
Before transporting the unit
The following process need to be taken after set tapering/parts replacement.
1.  Press the ON/STAND-BY button to enter stand-by mode.
2.  While pressing down the 
 button and the X-BASS/DEMO button, press the ON/STAND-BY button until "CLEAR AL"appears.
3.  While pressing down the 
 / 
 button and the X-BASS/DEMO button, press the ON/STAND-BY button until "WAIT 
     FINISHED" appears.
4.  Unplug the AC cord and the unit is ready for transporting.
– 15 –
XL-HP600E
 The indicated voltage in each section is the one measured
by Digital Multimeter between such a section and the chas-
sis with no signal given.
1. In the tuner section,
indicates AM
indicates FM stereo
2. In the main section, a tape is being played back.
3. In the deck section, a tape is being played back.
4. In the power section, a tape is being played back.
5. In the CD section, the CD is stopped.
 Parts marked with “ 
1
 ” (                          ) are important for
maintaining the safety of the set. Be sure to replace these
parts with specified ones for maintaining the safety and
performance of the set.
NOTES ON SCHEMATIC DIAGRAM
 Resistor:
To differentiate the units of resistors, such symbol as K and
M are used: the symbol K means 1000 ohm and the symbol
M means 1000 kohm and the resistor without any symbol is
ohm-type resistor. Besides, the one with “Fusible” is a fuse
type.
 Capacitor:
To indicate the unit of capacitor, a symbol P is used: this
symbol P means pico-farad and the unit of the capacitor
without such a symbol is microfarad. As to electrolytic
capacitor, the expression “capacitance/withstand voltage”
is used.
(CH), (TH), (RH), (UJ): Temperature compensation
(ML): Mylar type
(P.P.): Polypropylene type
 Schematic diagram and Wiring Side of P.W.Board for this
model are subject to change for improvement without prior
notice.
REF. NO
DESCRIPTION
POSITION
SW720
VIDEO/AUX
ON—OFF
SW721
DISC 3 EJECT
ON—OFF
SW722
DISC 2 EJECT
ON—OFF
SW723
DISC 1 EJECT
ON—OFF
SW724
DISC 1
ON—OFF
SW725
DISC 2
ON—OFF
SW726
DISC 3
ON—OFF
SW727
EQUALISER
ON—OFF
SW728
X-BASS/DEMO
ON—OFF
SWB101
CAM 1
ON—OFF
SWB102
CAM 2
ON—OFF
SWB103
CAM 3
ON—OFF
SWB104
CAM 4
ON—OFF
SWB105
CD EJECT
ON—OFF
SWB106
CD TRAY CLOSE
ON—OFF
SWB107
CD IN
ON—OFF
SWB108
CD SET
ON—OFF
SW4
PICKUP IN
ON—OFF
SW701
ON/STAND-BY
ON—OFF
SW702
CLOCK
ON—OFF
SW703
TIMER/SLEEP
ON—OFF
SW704
TUNING/TIME UP
ON—OFF
SW705
TUNING/TIME DOWN
ON—OFF
SW706
REC/PAUSE
ON—OFF
SW707
REVERSE MODE
ON—OFF
SW708
MEMORY/SET
ON—OFF
SW712
PRESET UP
ON—OFF
SW713
PRESET DOWN
ON—OFF
SW714
PLAY
ON—OFF
SW715
STOP
ON—OFF
SW716
REVERSE PLAY
ON—OFF
SW717
CD
ON—OFF
SW718
TUNER (BAND)
ON—OFF
SW719
TAPE
ON—OFF
TYPES OF TRANSISTOR AND LED
REF. NO
DESCRIPTION
POSITION
(1)  (2) (3) 
(S) (G) (D) 
E   C    B 
FRONT
VIEW
KRC102 M
KRC104 M
KTA1266 GR
KTA1271 Y
KTA1273 Y
SLR342VC
FRONT
VIEW
KTA1274 Y
KTC3199 GR
KTC3203 Y
2SC380 O
2SC1845 F
XL-HP600E
– 16 –
T
T
DATA
DATACK
LRSY
Stopped
CH1=2 V
DC   10:1
CH2=2 V
DC   10:1
CH3=2 V
DC   10:1
µ
s/div
(5 
µ
s/div)
NORM:100 kS/s
1
2
3
=Record Length=
Smoothing :   ON
CH1  :        0.00 V
CH2  :        0.00 V
Main  :        5 K
Zoom  :     100
Mode  :   AUTO
Type   :   EDGE CH3
Delay  :                    0.0 ns
Hold off  :                0.2 
µ
s
CH3  :        0.00 V
CH4  :        0.00 V
BW   : FULL
=Trigger=
=Filter=
=Offset=
CH3
  v/DIV
       2 V
1999/04/05  20:50:17
10
IC1   58
IC1  59
IC1  60
11
12
T
T
DOUT
Stopped
CH1=2 V
DC   10:1
500 ns/div
1999/04/07  09:25:28
(500 ns/div)
NORM:200 MS/s
1
=Record Length=
Smoothing :   ON
CH1  :        0.00 V
CH2  :        0.00 V
Main  :         1 K
Zoom  :      100
Mode  :   NORMAL
Type   :   EDGE CH1
Delay  :               2.887 ms
Hold off  :                0.2 
µ
s
CH3  :        0.00 V
CH4  :        0.00 V
BW   : FULL
=Trigger=
=Filter=
=Offset=
9
IC1  39
T
FDO
PDO2
PDO1
Stopped
CH1=500 mV
DC   10:1
CH3=1 V
DC   10:1
CH4=1 V
DC   10:1
500 ms/div
(500 ms/div)
NORM:20 kS/s
1
4
3
=Record Length=
Smoothing :   ON
CH1  :      0.000 V
CH2  :          0.0 V
Main  :      100 K
Zoom  :         2 K
Mode  :   AUTO
Type   :   EDGE CH2
Delay  :                    0.0 ns
Hold off  :                0.2 
µ
s
CH3  :        0.00 V
CH4  :        0.00 V
BW   : FULL
=Trigger=
=Filter=
=Offset=
CH1
  v/DIV
  500 mV
1999/04/05  17:33:17
1
IC1  21
7
IC1  73
8
IC1  74
T
T
FDO
SPDO
Stopped
CH1=200 mV
DC   10:1
CH2=500 mV
DC   10:1
500 ms/div
1999/04/07  09:51:15
(500 ms/div)
NORM:20 kS/s
2
1
=Record Length=
Smoothing :   ON
CH1  :      0.000 V
CH2  :      0.000 V
Main  :      100 K
Zoom  :         2 K
Mode  :   NORMAL
Type   :   EDGE CH2
Delay  :               2.924 ms
Hold off  :                0.2 
µ
s
CH3  :        0.00 V
CH4  :        0.00 V
BW   : FULL
=Trigger=
=Filter=
=Offset=
1
IC1  21
6
IC1  22
T
T
TE
DRF
Stopped
CH1=10 V
DC   10:1
CH2=1 V
DC   10:1
100 ms/div
(100 ms/div)
NORM:100 kS/s
2
1
=Record Length=
Smoothing :   ON
CH1  :           0.0 V
CH2  :         0.00 V
Main  :      100 K
Zoom  :         2 K
Mode  :   NORMAL
Type   :   EDGE CH1
Delay  :               2.924 ms
Hold off  :                0.2 
µ
s
CH3  :         0.00 V
CH4  :         0.00 V
BW   : FULL
=Trigger=
=Filter=
=Offset=
3
IC1  67
4
IC1  15
Vp-p=1.0 V~1.3 V
0.5 mV/div,0.5 
µ
sec/div
5
IC1   4
T
FDO
DRF
TE
Stopped
CH1=500 mV
DC   10:1
CH2=10 V
DC   10:1
CH3=1 V
DC   10:1
500 ms/div
(500 ms/div)
NORM:20 kS/s
1
2
3
=Record Length=
Smoothing :   ON
CH1  :      0.000 V
CH2  :          0.0 V
Main  :      100 K
Zoom  :         2 K
Mode  :   AUTO
Type   :   EDGE CH1
Delay  :                   0.0 ns
Hold off  :                0.2 
µ
s
CH3  :        0.00 V
CH4  :        0.00 V
BW   : FULL
=Trigger=
=Filter=
=Offset=
-3 div
-1 div
0 div
+1 div
+3 div
CH  Position  To
CH2
  Position
  0.20 div
1
IC1  21
3
IC1  67
4
IC1  15
T
FDO
TDO
Stopped
CH1=500 mV
DC   10:1
CH3=500 mV
DC   10:1
500 ms/div
(500 ms/div)
NORM:20 kS/s
1
3
=Record Length=
Smoothing :   ON
CH1  :      0.000 V
CH2  :          0.0 V
Main  :      100 K
Zoom  :         2 K
Mode  :   AUTO
Type   :   EDGE CH1
Delay  :                   0.0 ns
Hold off  :                0.2 
µ
s
CH3  :      0.000 V
CH4  :        0.00 V
BW   : FULL
=Trigger=
=Filter=
=Offset=
CH1
  v/DIV
  500 mV
1
IC1  21
2
IC1  20
WAVEFORMS OF CD CIRCUIT
Page of 64
Display

Click on the first or last page to see other XL-HP600 (serv.man21) service manuals if exist.