DOWNLOAD Sharp SD-SH111 (serv.man23) Service Manual ↓ Size: 8.18 MB | Pages: 124 in PDF or view online for FREE

Model
SD-SH111 (serv.man23)
Pages
124
Size
8.18 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio / System
File
sd-sh111-sm23.pdf
Date

Sharp SD-SH111 (serv.man23) Service Manual ▷ View online

– 21 –
SD-SH111
Supplementary notes:
1. The DVD/CD lid cannot be opened or closed (loading or unloading discs) in this test mode. After loading a disc,
    turn the power off to enter this test mode.
2. Operations of keys unrelated to the DVD operations are not accepted except for the POWER key. Therefore, you
     cannot switch functions, control volume, or control DSP, etc. The controls of electronic volume IC, input selector
    of the A/D and D/A converter, and monitor output are fixed to the settings of the DVD/CD functions.
3. AMP Test Mode
Outline:
In this test mode, all the operations except for volume control can be controlled in the same way as in the regular
power on state. The function can be switched to another, and the DVD can be played as well as the AC3 and DTS
multichannel playback, etc.
Only the volume control differs from the normal operation, and it can be changed among only 4 levels of 0, 1, 25,
and 40.
   Function:
1. After entering the test mode, start the unit as set to the VTR (VTR1) function in the same manner as the normal
    operation.
2. Start up the unit with the volume set to 25 (-16dB) and the surround set to the STEREO mode. X-BASS must be
    turned off.
3. The volume can be increased or decreased among 4 levels of 0, 1, 25, and 40 only if the volume control key input
    is performed.
4. “AMP TEST” is always displayed at the bottom of the FL. It changes to the operational indication for 3 seconds
    only when the following operations are performed. All the controls except for the display perform the same
    operations.
    • The volume level is displayed when it is changed.
    • When the X-BASS key is operated, its ON/OFF status appears.
    • The frequency appears when the function is switched to TUNER.
    • The operation is displayed for the first 3 seconds when the DVD play, stop, or pause operation is performed.
    • When various errors occur. In this case, the error is always displayed until it is restored.
  The elapsed time during DVD/CD playback is not displayed.
Function:
Audio circuit test
a) Volume levels can be set in 3 steps (low, middle and high).
Initial settings
1. Volume:
step 2 (-16 dB)
2. X-BASS:
OFF
3. Function:
test
4. Function:
VTR
5. Surround mode:
STEREO
Operation
Volume levels can be controlled in 4 steps below.
Other operations are performed normally.
Step of test mode
Normal volume level
Display
Volume
0
0
0
-
1
1
1
-80 dB
2
25
25
-16 dB
3
40
40
0  dB
SD-SH111
– 22 –
Key
Segment
4. KEY Test Mode
Outline:
This is to check that the system microcomputer properly acknowledges the key operations on the main unit.
Operation: In this test mode, the power is supplied only for the display, and all the FL indications are turned off as in the test
menu mode.
Then, the indication of 8 digits that corresponds to the key identified by the system microcomputer is displayed in
the FL.
When the power key is pressed, the whole FL is lit for 2 seconds before its power is turned off and the test mode
is canceled.
PLAY
KEY A1
STOP
KEY A2
FUNCTION
KEY A3
DGI/ANA/BAND
KEY A4
Key
Segment
OPEN/CLOSE
KEY B1
SKIP DOWN
KEY B2
SKIP UP
KEY B3
VOLUME DOWN
KEY B4
VOLUME UP
KEY B4
5. DVD/CD Lid Test Mode
Outline:
The DVD/CD lid is opened and closed repeatedly and the number of repetitions is displayed in the FL. If the finger
jam or time over is detected while the lid is opening or closing, the lid operations is stopped and the error
indication and the number of repetitions are displayed.
Keys available in this test mode are POWER, PLAY, STOP, and OPEN/CLOSE only.
Operation: 1. After entering the test mode, “TEST” is displayed at the top of the FL and “00000” at the bottom, and the unit waits
until the next key operation is performed.
If the DVD/CD lid is not closed, close it during this operation.
2. The test is commenced by pressing the OPEN/CLOSE key. The DVD/CD lid is controlled in the following
procedure
and the FL shows the number of open/close repetitions. The test operation is repeated until the STOP
or POWER
key is pressed or the error is detected.
a. Open the DVD/CD lid until the OPEN completion is detected.
b. When the OPEN completion is detected, stop the DVD/CD lid operation and wait for 2 seconds.
c. After 2 seconds, close the DVD/CD lid until the CLOSE completion is detected.
d. When the CLOSE completion is detected, stop the DVD/CD lid operation, display the counter in the FL and
    wait for 2 seconds.
e. After 2 seconds, return to step a and repeat the procedure.
3. If finger jam is detected in the middle of the closing operation, or the error that the opening and closing of the lid
does not complete in 5 seconds is detected, “Er 
∗∗∗∗∗
 is displayed at the bottom of the FL, the motor is stopped,
and the unit enters the stand-by mode. (
∗∗∗∗∗
 indicates the number of repetition until the test is stopped.)
4. If the STOP key is pressed, the lid operation is stopped at that point (even in the middle of an operation). The
FL indication does not change. The interrupted operation and counting resume from the same point if the OPEN/
CLOSE key is pressed in this state.
5. Pressing the POWER key closes the lid if it is open, and the test mode is canceled to reset.
Supplementary note:
1. The counter continues endlessly. When it reaches the maximum value (99999), the counter returns to “00000”
and continues counting.
6. DVD unit ROM write test mode
Outline:
This mode is to set the microcomputer of the DVD unit to the write mode onto FLASH ROM. In this test mode, “TEST”
is displayed at the top of the FL and “DVD WRITE” at the bottom. All the key operations except for the POWER key
are prohibited.
Operation: 1. Set the output DVD WRITE port to “L”, and the DVD +B port to “H”.
2. Other ports maintains the state at the transition to the test menu mode, and do not detect any change of input
    except for SYS_STOP and RESET (communication with the DVD unit is interrupted.)
3. If the power key is pressed during this operation, the test mode is canceled and the reset process is started.
– 23 –
SD-SH111
7. TUNER Test Mode
Outline:
Start up the unit as set to the TUNER function in the same procedure as the normal operation. Operations and
indication after startup are identical with the normal operations. However, what is different is that the frequencies
as shown in the table below are set to the tuner preset memory in advance.
Test mode operation:
(1) After entering the test mode, start up the unit with the tuner set to the preset No. 1 station, in the same manner
     as in the regular startup. When starting up, the following stations are preset which vary according to the
     destination.
(2) The operation is identical with the normal operation after startup.
(3) If the POWER key is pressed, irregular data is written in the RAM check data and the microcomputer is reset.
     With this operation, abnormal memory is detected during the reset process, and microcomputer settings are
     initialized.
Preset memory in the TUNER TEST mode
P 1
P 2
P 3
P 4
P 5
P 6
P 7
P 8
P 9
P10
87.50
108.00
90.00
106.00
98.00
530 k
1,720 k
600 k
1,400 k
990 k
SD-SH111
– 24 –
DVD TEST MODE
The preparation date display of the program
10000000  ********
                                                   (Last updata)
Model number display
10000001  *******#
                                               (Model number)
The version display of the program
10000002  ********
                                                 (Program ver.)
Reagion number display
10000003  0000000*
                          (Region code:Binary display)
Color bar display
20000001  00000000 (FIP)
Dynamic Test
30000000  00000000
Micro-code number display
10000004  ********
                                              (Microcode ver.)
The preparation date display of the servo program
10000005  ********
                                                     (Servo ver.)
It is returned to the test mode initial image plane.
<The "2" key of the remote controller is pushed.>
<The "3" key of the remote controller is pushed.>
<The "1" key of the remote controller is pushed.>
Test mode initial image plane
F0000000  *$&#####
The "Playback" key of the remote controller is pushed.
The "Playback" key of the remote controller is pushed.
The "Playback" key of the remote controller is pushed.
The "Reactivation" key of the remote controller is pushed.
The "Playback" key of the remote controller is pushed.
The "Playback" key of the remote controller is pushed.
The "Stop" key of the remote controller is pushed.
There is no copy guard signal.
As for the symptom when it was
dubbed in the video tape recorder?
It is returned to the test mode initial image plane.
To (1)
Micro-code is the thing of the process 
program of the system integrated circuit.
(* is a region number)
($ is a TV-TYPE)
(& is a model number)
(##### is a program version)
(* is a model number) (# is a region number)
(* is a region number)
  DVD TEST MODE
  DVD ROM RENEWAL MODE
Page of 124
Display

Click on the first or last page to see other SD-SH111 (serv.man23) service manuals if exist.