DOWNLOAD Sharp AY-X127E Service Manual ↓ Size: 1.99 MB | Pages: 45 in PDF or view online for FREE

Model
AY-X127E
Pages
45
Size
1.99 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner
File
ay-x127e.pdf
Date

Sharp AY-X127E Service Manual ▷ View online

AH-X127E
AU-X127E
AY-X127E
AE-X127E
31
REFRIGERANT CYCLE
Figure R-2. Refrigeration Cycle for AY-X127E
s
1
2
Capillary tube
3
Strainer
Outdoor unit
Condensor
Evaporator
Indoor unit
Compressor
Flare coupling
Flare coupling
Silencer
4
valve
valve
Accumulator
Figure R-1. Refrigeration Cycle for AH-X127E
1
4
C
2
Accumulator
3
Strainer
Outdoor unit
Condensor
Evaporator
Reverse valve
Comp-
ressor
Valve
Valve
Silencer
Cooling
Heating
Coil
Capillary 
tube A
Capillary 
tube B
Flare coupling
Indoor unit
Flare coupling
s
AH-X127E
AU-X127E
AY-X127E
AE-X127E
32
Indoor side 
Standard conditions: 
Dry-bulb Temp. (˚C)
Relative Humidity (%)
27
Cooling
47
Outdoor side 
Dry-bulb Temp. (˚C)
Relative Humidity (%)
35
40
AH-X127E
Temperature at each part and pressure in 3-way valve
Operation 
mode
Cool
(Max.)
Cool
1
2
3
4
3-way valve
pressure
(kg/cm
2
 G)
107˚C
48˚C
12˚C
8˚C
4.3
67˚C
44˚C
14˚C
11˚C
6.0
111
50 settle
AH-X127E
No.
Hz
Capillary tube
O.D
I.D.
L
ø3.2
ø1.8
900
AH-X127E
Dimension of Capillary tube
AH-X127E
AU-X127E
AY-X127E
AE-X127E
33
Indoor side 
Standard conditions: 
Dry-bulb Temp. (˚C)
Relative Humidity (%)
27
20
Cooling
Heating
47
Outdoor side 
Dry-bulb Temp. (˚C)
Relative Humidity (%)
35
7
40
87
AY-X127E
Temperature at each part and pressure in 3-way valve
Operation 
mode
Cool
(Max.)
Heat
(Max.)
Cool
Heat
1
2
3
4
3-way valve
pressure
(kg/cm
2
 G)
107˚C
46˚C
13˚C
5˚C
4.2
103˚C
0˚C
39˚C
-1˚C
20.0
69˚C
44˚C
14˚C
12˚C
6.0
55˚C
2˚C
32˚C
 2˚C
12.7
111 
more than120
50 settle
50 settle
AY-X127E
No.
Hz
Capillary tube A
O.D
I.D.
L
ø3.2
ø1.8
1100
Capillary tube B
ø3.2
ø1.8
500
AY-X127E
Dimension of Capillary tube
Page of 45
Display

Click on the first or last page to see other AY-X127E service manuals if exist.