33
AH/AY-AP18DR
AH/AY-AP24DR
Cycle temperature and service port pressure
ISO condition
Dimension of Capillary tube
Cycle temperature and service port pressure
ISO condition
Dimension of Capillary tube
Indoor side
Outdoor side
Temperature (˚C)
Temperature (˚C)
Relative humididity (%)
Relative humididity (%)
27
47
35
40
Cooling
20
-
7
87
Heating
Indoor side
Outdoor side
Temperature (˚C)
Temperature (˚C)
Relative humididity (%)
Relative humididity (%)
27
47
35
40
Cooling
O.D.
I.D.
L
Capillary tube 
ø 3.2
ø 1.8
600
O.D.
I.D.
L
Capillary tube 
ø 3.5
ø 2.0
700
For AH-AP18DR
For AH-AP24DR
Cooling
Heating
NO. Condition
Model
AY-AP18DR
1
2
3
4
Service port guage pressure
85˚C
79˚C
42˚C
2˚C
12˚C
39˚C
9˚C
-3˚C
0.89MPa
2.65MPa
Cooling
Heating
AY-AP24DR
85˚C
84˚C
42˚C
2˚C
11˚C
39˚C
7˚C
-2˚C
0.76MPa
3.2MPa
Based on 'ISO 5151:1994(E),condition T1'
(at 220V refrigerant pipes length 7.5m)
Cooling
Cooling
NO. Condition
Model
AH-AP18DR
1
2
3
4
Service port guage pressure
80˚C
86˚C
43˚C
43˚C
12˚C
11˚C
7˚C
7˚C
0.89MPa
0.77MPa
AH-AP24DR
Based on 'ISO 5151:1994(E),condition T1'
(at 220V refrigerant pipes length 7.5m)
O.D.
I.D.
L
Capillary tube A
ø 3.2
ø 1.8
700
Capillary tube C
(Upper  row)
  
ø 2.7
ø 1.6
150
Capillary tube B
ø 3.2
ø 1.8
300
Capillary tube D
(Lower  row)
  
ø 2.7
ø 1.6
150
O.D.
I.D.
L
Capillary tube A
ø 3.2
ø 2.0
500
Capillary tube B
ø 3.2
ø 2.0
700
Capillary tube C
(Upper  row)
ø 2.7
ø 1.6
150
Capillary tube D
(Lower  row)
ø 2.7
ø 1.6
244
For AY-AP18DR
For AY-AP24DR
AH/AY-AP18DR
AH/AY-AP24DR
34
PERFORMANCE CURVES
Figure P-1. At Cooling for AY-AP18DR
Figure P-2. At Heating for AY-AP18DR
Indoor air temp. : 20˚C
Indoor fan speed : Hi
Heating capacity(BTU/h)
3.5
4.5
5.0
6.0
6.5
(KW)
2500
2000
50
Outside air temp.(˚C)
Outlet air temp.(˚C)
5.5
4.0
45
40
35
30
25
20
-10
-8
-6
-4
-2
0
2
4
6
8
10
1500
Indoor air temp. : 27˚C
Indoor humidity : 47RH%
Indoor fan speed : Hi
14000
18000
20000
22000
16000
12000
16000
17000
18000
19000
Cooling capacity(BTU/h)
2500
4.5
5.0
5.5
(kW)
1500
Power input(W)
11
Outside air temp.(˚C)
Inside Outlet air temp.(˚C)
3 0 3 1 3 2 3 3 3 4 3 5 3 6 3 7
3 8 3 9 4 0
12
13
14
15
2000
35
AH/AY-AP18DR
AH/AY-AP24DR
Figure P-3. At Cooling for AY-AP24DR
Figure P-4. At Heating for AY-AP24DR
REFRIGERANT PIPE INSTALLATION WORKS
Refrigerant pipe length and level difference between the indoor and outdoor units.
The shorter refrigerant pipe, the highter the machine capabillity. Keep the pipe line as short as possible.
If actual pipe length exceeds 7.5m, and refrigerant (R-410A) 15g per 1m.
MODEL 
AY-AP18DR
AY-AP24DR
PIPE SIZE
GAS
LIQUID
STANDARD PERMISSIBLE
LENGTH
PERMISSIBLE LEVEL
DIFERENCE
1/2"
1/2"
1/4"
1/4"
15m
10m
15m
10m
Indoor air temp. : 20˚C
Indoor fan speed : Hi
24000
28000
Heating capacity(BTU/h)
6.0
7.0
7.5
8.5
9.0
(KW)
3000
2500
60
Input(W)
Outside air temp.(˚C)
Outlet air temp.(˚C)
8.0
6.5
55
50
45
40
35
30
-10
-8
-6
-4
-2
0
2
4
6
8
10
2000
26000
30000
Indoor air temp. : 27˚C
Indoor humidity : 47RH%
Indoor fan speed : Hi
22000
20000
3500
22000
23000
24000
Cooling capacity(BTU/h)
3000
6.0
6.5
7.0
(kW)
2000
Power input(W)
11
Outside air temp.(˚C)
Inside Outlet air temp.(˚C)
3 0 3 1 3 2 3 3 3 4 3 5 3 6 3 7
3 8 3 9 4 0
12
13
14
15
2500
21000
AH/AY-AP18DR
AH/AY-AP24DR
36
Figure P-5. At Cooling for AH-AP18DR
Figure P-6. At Cooling for AH-AP24DR
REFRIGERANT PIPE INSTALLATION WORKS
Refrigerant pipe length and level difference between the indoor and outdoor units.
The shorter refrigerant pipe, the highter the machine capabillity. Keep the pipe line as short as possible.
If actual pipe length exceeds 7.5m, and refrigerant (R-410A) 15g per 1m.
Indoor air temp. : 27˚C
Indoor humidity : 47RH%
Indoor fan speed : Hi
Power supply : 50Hz, 220V
22000
23000
24000
Cooling capacity(BTU/h)
3000
6.0
6.5
7.0
(kW)
2000
Power input(W)
11
Outside air temp.(˚C)
Inside Outlet air temp.(˚C)
3 0 3 1 3 2 3 3 3 4 3 5 3 6 3 7
3 8 3 9 4 0
12
13
14
15
2500
Indoor air temp. : 27˚C
Indoor humidity : 47RH%
Indoor fan speed : Hi
Power supply : 50Hz, 220V
21000
16000
17000
18000
Cooling capacity(BTU/h)
2500
4.5
5.0
5.5
(kW)
1500
Power input(W)
11
Outside air temp.(˚C)
Inside Outlet air temp.(˚C)
3 0 3 1 3 2 3 3 3 4 3 5 3 6 3 7
3 8 3 9 4 0
12
13
14
15
2000
MODEL 
AH-AP18DR
AH-AP24DR
PIPE SIZE
GAS
LIQUID
STANDARD PERMISSIBLE
LENGTH
PERMISSIBLE LEVEL
DIFERENCE
1/2"
1/2"
1/4"
1/4"
15m
10m
15m
10m